Supply Ability | 100 Sets per month |
Delivery Time | 15 days |
Packaging Details | Plywood case |
Keyword | Atomic Absorption Spectrophotometer |
Wavelength Range | 190 ~ 900nm |
Wavelength accuracy | ±0.15nm |
Warranty | 1 Year |
Size | 700mm×550mm×450mm |
Lamp turrets | 8 PCS |
Spectrum bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
Power supply | 220V±22V AC |
Weight | 75kg |
Operation | PC controlled |
Brand Name | YUYANG |
Model Number | 4530F |
Certification | ISO |
Place of Origin | CHINA |
View Detail Information
Explore similar products
ASTM D1266 Oil Analysis Equipment Gasoline And Kerosene Sulfur Content Tester
Automatic Kinematic Viscometer Oil Viscosity Testing Equipment
ASTM D86 Manual Type Distillation Apparatus Gasoline Oil Testing Equipment
ASTM D1160 Reduced Pressure Vacuum Distillation Boiling Point Test Apparatus
Product Specification
Supply Ability | 100 Sets per month | Delivery Time | 15 days |
Packaging Details | Plywood case | Keyword | Atomic Absorption Spectrophotometer |
Wavelength Range | 190 ~ 900nm | Wavelength accuracy | ±0.15nm |
Warranty | 1 Year | Size | 700mm×550mm×450mm |
Lamp turrets | 8 PCS | Spectrum bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
Power supply | 220V±22V AC | Weight | 75kg |
Operation | PC controlled | Brand Name | YUYANG |
Model Number | 4530F | Certification | ISO |
Place of Origin | CHINA | ||
High Light | oil analysis machine ,oil analyzer equipment |
Features:
This AAS machine is complete automatic controlling system;
The AA spectrophotometer can be worked with advanced graphite furnace temperature controlling technology;
Safe, reliable and convenient flame system;
Multi-functional software workstation;
This flame system atomic absorption spectrophotometer is ompletely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional);
Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term;
Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp;
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions;
Fully automated wavelength scanning and peak searching;
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout;
Deuterium lamp and self-absorption background regulation;
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called;
Measuring method of AAS machine: flame absorption method and emission method;
Result printing: parameter printing, data result printing and diagram printing;
Instrument Configuration:
Atomic Absorption Spectrophotometer 1pc
Air compressor without noise 1pc
PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)
Specifications:
Wavelength range | 190 ~ 900nm |
Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
Accuracy of the wavelength | ±0.15nm |
Receptivity of the wavelength | ≤0.04nm |
Base line stability | ≤0.002A/30min (Cu) |
Characteristic viscosity | 0.02μg/ml/1% (Cu) |
Checking limit | 0.004μg/ml (Cu) |
Preciseness | 0.5% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | Eight lamps |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Size and weight | 700mm×550mm×450mm 75Kg |
Power source | 220V±22V AC |
Flame System:
Acetylene air burner | 100mm |
Nitrous oxide acetylene flame head | 50mm |
Ignition dynamic baseline drift | ≤0.006A/30min |
(Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner |
Graphite Furnace:
The highest temperature | 3000℃ |
The largest temperature rising speed | ≥2000℃/S |
Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
Accuracy | Cu≤3% Cd≤3% |
Size and weight | 550mm×450mm×300mm 65Kg |
Safety system | Over current protection |
Protection | Low air pressure alarm, low cooling water flow alarm |
Power source and power | 220V±22V AC 7000W |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2007
Total Annual:
$ 1 Million-$ 2 Million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
YUYANG INDUSTRIAL CO., LIMITED (DONGGUAN YUYANG INSTRUMENT CO.,LTD) is Located in Wangjiang District (Dongguan City ,Guangdong Province, China),a famous historical town with prosperous industry and convenient transportation. We are a high-tech enterprise which is specialized in developing ... YUYANG INDUSTRIAL CO., LIMITED (DONGGUAN YUYANG INSTRUMENT CO.,LTD) is Located in Wangjiang District (Dongguan City ,Guangdong Province, China),a famous historical town with prosperous industry and convenient transportation. We are a high-tech enterprise which is specialized in developing ...