Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash |
Supply Ability | 15 sets per month |
Delivery Time | 15 work days |
Packaging Details | Wooden Case |
Standard | GB/T16556 |
Scope of application | of the mask |
Function | suitable for testing the flame retardant performance |
Test sample | mask |
Gas source | propane |
Relative humidity | ≤85% |
Ambient temperature | -5°C-30°C |
Power supply voltage | 220V±10%, 50HZ, 100W |
Brand Name | Daxian |
Model Number | DX8220 |
Certification | GB/T16556 |
Place of Origin | China |
View Detail Information
Explore similar products
UV Ultraviolet Mask Disinfection Test Machine Mask Sterilization Machine
UL817 Protective Mask Carbon Dioxide Volume Test Machine
ASTM D903 Respirator Ear Strap Strong Pull Machine CNS11888 With LCD Screen
EN 136 1998 AC220V 50Hz Mask Tester For Radiation Resistance Test
Product Specification
Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash | Supply Ability | 15 sets per month |
Delivery Time | 15 work days | Packaging Details | Wooden Case |
Standard | GB/T16556 | Scope of application | of the mask |
Function | suitable for testing the flame retardant performance | Test sample | mask |
Gas source | propane | Relative humidity | ≤85% |
Ambient temperature | -5°C-30°C | Power supply voltage | 220V±10%, 50HZ, 100W |
Brand Name | Daxian | Model Number | DX8220 |
Certification | GB/T16556 | Place of Origin | China |
High Light | Mask Flame Resistance Testing Equipment |
DX8220 Mask Flame Resistance Testing Equipment
Scope of application: It is suitable for testing the flame retardant performance of the mask, the instrument has six burners to apply flame to the test sample, and the test time is displayed digitally.
Conform to the standard: developed in strict accordance with the main technical parameters of the national standard GB/T16556.
Features: Automatic timing, digital display
The working conditions and main technical indicators of the instrument
a. Ambient temperature: -5°C-30°C;
b. Relative humidity: ≤85%;
c. Power supply voltage: 220V±10%, 50HZ, 100W;
d. The temperature of the burner flame at 250mm reaches 950 °C± 50 °C;
e. The flame application time is steplessly adjustable
f. Gas source: propane;
7. Test sample: mask.
Test steps:
a. Turn on the power supply and air source of the instrument, and check whether the "pressure adjustment", "flow adjustment" and "permanent lamp adjustment" on the instrument panel are in the off position.
b. Open the door of the test chamber, move the headform to install the test sample on the headform, adjust the distance from each burner to the test sample to 250mm according to the national standard, and manually remove the sample from the burner.
c. Turn on the power switch and the main valve of the gas source on the instrument, adjust the knob of "Everbright Light Adjustment" on the panel, and light the everlasting lamp with an open flame, the flame is about 20mm long. Press the "?" on the instrument panel display. button and then press the "▲" button, the monitor displays "1005".
The "pressure adjustment" on the adjustment instrument makes the indicated value of the pressure gauge around 0.12Mpa.
d. Press the "Run" button to adjust the "flow adjustment", at this time the burner is lit, adjust the air feed nut at the lower end of the burner, measure the temperature at the flame 250mm with a temperature measuring instrument to (950±50) °C, press the "Reset" button to extinguish the burner flame.
e. Then adjust the monitor on the panel and press "?" button, then press the "▲" button to display "0005", manually move the test sample to the test position, press the "run" button burner to ignite, the display starts to time, the burner will automatically extinguish after 5 seconds of flames, and the re-ignition time will start to time, pay attention to observe whether there is any re-combustion after the sample is flamed, if the re-combustion stops, press the "timing" button on the instrument, and the display will stop timing.
f. Record the continuous combustion time and observed phenomena.
g. Replace the sample with a new one and repeat operations 3.2-3.6. After the test, turn off the power supply and gas source, and clean and maintain the combustion box.
Packing list:
a. 1 test chamber and 1 headform
b. 1 medium pressure valve
c. Power cords: 1 pcs
d. fuses 0.5A: 2pcs
e. rubber tubes, 1.5 m
f. 1 copy of the instruction manual
g. 1 certificate of conformity
Company Details
Business Type:
Manufacturer
Year Established:
2004
Total Annual:
8,000,000-10,000,000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Daxian is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment ... Daxian is a professional manufacturer of Building materials/ Wire/ Plastics/ Rubber Fire retardant testing equipment 1. Fire Testing Equipment 2. Building Material Fire Tester 3. Wire and Cable Fire Tester 4. Environmental Test Chamber 5. Textile Testing Equipment ...