Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 10pcs / month |
Delivery Time | 20 work days |
Packaging Details | Paper Box |
Interface | USB |
Rise-fall time(20% to 80%) | 14-35pS |
Signal output amplitude (single-ended) | 200-1000mV |
Data signal input sensitivity (single-ended) | 50mVpp |
Material | metal |
Number of channels | 8 |
Operating temperature | 10~50℃ |
Brand Name | YOUCii |
Model Number | U9264Q |
Place of Origin | CHINA |
View Detail Information
Explore similar products
2 Channel 4 Channel Light Source Power Meter 850nm 980nm 1310nm
Multi-Ch Fiber Optical Power Meter With Laser Source
Double Channel Light Source Power Meter RS232 Communication Interface
USB Communication Interface Optical Power Meter 850nm To 1700nm
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 10pcs / month |
Delivery Time | 20 work days | Packaging Details | Paper Box |
Interface | USB | Rise-fall time(20% to 80%) | 14-35pS |
Signal output amplitude (single-ended) | 200-1000mV | Data signal input sensitivity (single-ended) | 50mVpp |
Material | metal | Number of channels | 8 |
Operating temperature | 10~50℃ | Brand Name | YOUCii |
Model Number | U9264Q | Place of Origin | CHINA |
High Light | High Speed PAM4 Error Meter ,Optical Transceiver Module PAM4 Error Meter ,400G PAM4 Error Meter |
400G PAM4 Error Meter High-Speed Optical Transceiver Module Equipment
The 400G PAM4 error analyzer is a high-performance error analyzer designed to test PAM4 (four-level pulse amplitude modulation) signals at 400G rates. It can switch NRZ (non-returnto-zero code) and PAM4 code without any peripheral accessories, providing an effective guarantee for the automated production and testing of high-speed optical transceiver modules.
Main feature
High speed and high performance: The 400G PAM4 error meter supports transmission rates up to 400G, which can meet the test requirements of current and future high-speed communication systems. At the same time, its high-performance error analysis capability can ensure the accuracy and reliability of the test.
Multi-channel parallel testing: Some 400G PAM4 error detectors (such as BERTWaveE856F) support 8 channels in parallel, with a single channel up to 28.9GBd, greatly improving test efficiency.
Flexible code type selection: The 400G PAM4 error tester supports a variety of NRZ and PAM4 code types, including PRBS (pseudo-random binary sequence) series code types, user-defined code types, etc., to meet the needs of different test scenarios.
Adjustable output signal: the amplitude of the output signal can be adjusted, the polarity can be freely flipped, and it supports two test modes: timing and continuous, providing more flexibility and convenience for testing.
FEC support: Some 400G PAM4 error detectors (such as BERTWaveE856F) support KP4-RS (544, 514) FEC (forward error correction), which further improves test accuracy and reliability.
Technical parameter
No. | Argument | MIN | Model | MAX | Unit |
1 | Signal coding mode | NRZ/PAM4 | |||
2 | Data rate | 6.144 | 6.144,10.3125,20,25,25.78125,26.5625,28.05 | 28.05 | Gbps |
3 | Code pattern | PRBS7,PRBS9,PRBS11,PRBS13,PRBS15,PRBS16,PRBS23,PRBS31,USER PRBS13Q,SSPRQ,JP03A,JP03B. | |||
4 | Rise-fall time(20% to 80%) | 14 | 35 | pS | |
5 | Pattern reversal | The signal at the receiving end is automatically reversed | |||
6 | Signal output amplitude (single-ended) | 200 | 800 | 1000 | mV |
7 | 25G Data Output jitter (RMS) | 500 | 700 | fs | |
8 | Data input/output interface | Differential, AC coupling, 50 ohm impedance, female 2.92mm SMA | |||
9 | Clock output | 0.2 | 6.64 | 13.28 | GHz |
10 | Data signal input sensitivity (single-ended) | 50 | mVpp | ||
11 | Data output eye map intersection NRZ | 49 | 50 | 52 | % |
12 | PAM4 Eye height (per eye height) | 80 | 110 | 200 | mV |
13 | Linearity of PAM eye map | 0.95 | 0.98 | 1 | |
14 | Operating temperature | 10 | 25 | 50 | °C |
The 400G PAM4 error meter is widely used in the development and production of optical transceiver modules (such as QSFP-DD/OSFP/QSFP28/CFPx/CXP), especially in the testing of parallel 400G products. In addition, it can also be used in the development and production of optical devices/subsystems, incoming quality inspection and production of system equipment suppliers, installation and troubleshooting of system equipment, and performance verification of cable assemblies.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
3000000-3500000
Ecer Certification:
Verified Supplier
"To do import substitution, to create national brand" is the journey that Uc Instruments is brave to climb and the goal of continuous progress. Guangzhou UC Instruments., Co. Ltd. was founded in March 2009 and has been recognized as a high-tech enterprise in Guangdong Province... "To do import substitution, to create national brand" is the journey that Uc Instruments is brave to climb and the goal of continuous progress. Guangzhou UC Instruments., Co. Ltd. was founded in March 2009 and has been recognized as a high-tech enterprise in Guangdong Province...
Get in touch with us
Leave a Message, we will call you back quickly!