China 400G PAM4 Error Meter High-Speed Optical Transceiver Module Equipment
China 400G PAM4 Error Meter High-Speed Optical Transceiver Module Equipment

  1. China 400G PAM4 Error Meter High-Speed Optical Transceiver Module Equipment

400G PAM4 Error Meter High-Speed Optical Transceiver Module Equipment

  1. MOQ: 1
  2. Price: Negotiate price
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 10pcs / month
Delivery Time 20 work days
Packaging Details Paper Box
Interface USB
Rise-fall time(20% to 80%) 14-35pS
Signal output amplitude (single-ended) 200-1000mV
Data signal input sensitivity (single-ended) 50mVpp
Material metal
Number of channels 8
Operating temperature 10~50℃
Brand Name YOUCii
Model Number U9264Q
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 10pcs / month
Delivery Time 20 work days Packaging Details Paper Box
Interface USB Rise-fall time(20% to 80%) 14-35pS
Signal output amplitude (single-ended) 200-1000mV Data signal input sensitivity (single-ended) 50mVpp
Material metal Number of channels 8
Operating temperature 10~50℃ Brand Name YOUCii
Model Number U9264Q Place of Origin CHINA
High Light High Speed PAM4 Error MeterOptical Transceiver Module PAM4 Error Meter400G PAM4 Error Meter

400G PAM4 Error Meter High-Speed Optical Transceiver Module Equipment

 

The 400G PAM4 error analyzer is a high-performance error analyzer designed to test PAM4 (four-level pulse amplitude modulation) signals at 400G rates. It can switch NRZ (non-returnto-zero code) and PAM4 code without any peripheral accessories, providing an effective guarantee for the automated production and testing of high-speed optical transceiver modules.

 

Main feature
High speed and high performance: The 400G PAM4 error meter supports transmission rates up to 400G, which can meet the test requirements of current and future high-speed communication systems. At the same time, its high-performance error analysis capability can ensure the accuracy and reliability of the test.


Multi-channel parallel testing: Some 400G PAM4 error detectors (such as BERTWaveE856F) support 8 channels in parallel, with a single channel up to 28.9GBd, greatly improving test efficiency.


Flexible code type selection: The 400G PAM4 error tester supports a variety of NRZ and PAM4 code types, including PRBS (pseudo-random binary sequence) series code types, user-defined code types, etc., to meet the needs of different test scenarios.


Adjustable output signal: the amplitude of the output signal can be adjusted, the polarity can be freely flipped, and it supports two test modes: timing and continuous, providing more flexibility and convenience for testing.


FEC support: Some 400G PAM4 error detectors (such as BERTWaveE856F) support KP4-RS (544, 514) FEC (forward error correction), which further improves test accuracy and reliability.

 

Technical parameter

No. Argument MIN Model MAX Unit
1 Signal coding mode NRZ/PAM4  
2 Data rate 6.144 6.144,10.3125,20,25,25.78125,26.5625,28.05 28.05 Gbps
3 Code pattern PRBS7,PRBS9,PRBS11,PRBS13,PRBS15,PRBS16,PRBS23,PRBS31,USER PRBS13Q,SSPRQ,JP03A,JP03B.  
4 Rise-fall time(20% to 80%)   14 35 pS
5 Pattern reversal The signal at the receiving end is automatically reversed  
6 Signal output amplitude (single-ended) 200 800 1000 mV
7 25G Data Output jitter (RMS)   500 700 fs
8 Data input/output interface Differential, AC coupling, 50 ohm impedance, female 2.92mm SMA  
9 Clock output 0.2 6.64 13.28 GHz
10 Data signal input sensitivity (single-ended)   50   mVpp
11 Data output eye map intersection NRZ 49 50 52 %
12 PAM4 Eye height (per eye height) 80 110 200 mV
13 Linearity of PAM eye map 0.95 0.98 1  
14 Operating temperature 10 25 50 °C

 

 

The 400G PAM4 error meter is widely used in the development and production of optical transceiver modules (such as QSFP-DD/OSFP/QSFP28/CFPx/CXP), especially in the testing of parallel 400G products. In addition, it can also be used in the development and production of optical devices/subsystems, incoming quality inspection and production of system equipment suppliers, installation and troubleshooting of system equipment, and performance verification of cable assemblies.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2009

  • Total Annual:

    3000000-3500000

  • Ecer Certification:

    Verified Supplier

"To do import substitution, to create national brand" is the journey that Uc Instruments is brave to climb and the goal of continuous progress.   Guangzhou UC Instruments., Co. Ltd. was founded in March 2009 and has been recognized as a high-tech enterprise in Guangdong Province... "To do import substitution, to create national brand" is the journey that Uc Instruments is brave to climb and the goal of continuous progress.   Guangzhou UC Instruments., Co. Ltd. was founded in March 2009 and has been recognized as a high-tech enterprise in Guangdong Province...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou UC Instruments., Co. Ltd.
  • R102, #24 Huangcun East Road,Tianhe District, Guangzhou 510660
  • https://www.fiberoptic-equip.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement