Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram, T/T |
Supply Ability | 7 pcs+per month |
Delivery Time | 20 work days |
Packaging Details | Carton |
Signal acquisition mode | Sampling (Normal), Envelope, Average |
Trigger cutoff | ±1.5V:5ms ~100ms |
Time interval accuracy (jitter mode) | 0.25ps(10GHz), 0.0625ps(30GHz) |
Power (external power adapter) | 50Hz,5V,3A,6W |
Brand Name | YOUCII |
Model Number | U9110A |
Certification | CU,IOS |
Place of Origin | China |
View Detail Information
Explore similar products
2 Channel 4 Channel Light Source Power Meter 850nm 980nm 1310nm
Multi-Ch Fiber Optical Power Meter With Laser Source
Double Channel Light Source Power Meter RS232 Communication Interface
USB Communication Interface Optical Power Meter 850nm To 1700nm
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram, T/T | Supply Ability | 7 pcs+per month |
Delivery Time | 20 work days | Packaging Details | Carton |
Signal acquisition mode | Sampling (Normal), Envelope, Average | Trigger cutoff | ±1.5V:5ms ~100ms |
Time interval accuracy (jitter mode) | 0.25ps(10GHz), 0.0625ps(30GHz) | Power (external power adapter) | 50Hz,5V,3A,6W |
Brand Name | YOUCII | Model Number | U9110A |
Certification | CU,IOS | Place of Origin | China |
High Light | 10Gbps Full Rate Clock Recovery Instrument ,6W Clock Recovery Instrument |
10Gbps Full Rate Clock Recovery Instrument Provides Clock Recovery Signal
U9110A 10G optical oscilloscope is the latest digital communication analysis solution launched by Youxi Instrument. It provides an ideal measuring tool for the manufacturing of optical communication devices.
The results of the U9110A DCA measurement are not only raw data, but also histograms with time and amplitude, Mask tests, statistical tests, etc. It provides a set of communication indicator test Settings, including interval period, rise time, fall time, cross percentage, extinction ratio, jitter, and amplitude measurement. It also includes SDH/SONET, Mask tests for Gigabit Ethernet, and other standard single compliance tests.
Function introduction:
1. Automatic ITU/ANSI Mask test
2. User operation and graphical display interface based on PC Ethernet communication software
3. Modular structure, fast sampling rate
4. High-fidelity signal (Jitter< 0.1ps, RMS-Typical)
Optical oscilloscope introduction:
An optical oscilloscope is a measuring instrument that usually consists of a measuring head (including a transmitter and receiver) and a display memory. The measuring head converts high-speed electrical signals into optical signals and transmits these optical signals to the display memory for processing. Display memory is used to store, process, and display optical signal data.
An optical oscilloscope works by sending a high-speed electrical signal into the measuring head, which is converted into very short laser pulses, which are then transmitted to the display memory and recorded. By observing the recorded optical signal data, it is possible to infer the properties of the original electrical signal, such as frequency, amplitude, offset, etc.
Specification
standard rate | 1.25G ~30G |
Measurement accuracy Mask margin (Margin) | ±3 % |
Display Characteristics Image Resolution | 1024×768 pixels |
digital measurement system | Support 1~2 optical channel measurement, refresh optional measurement 3 times per second |
Signal acquisition mode | Sampling (Normal), Envelope, Average |
RMS noise | 0.25mV (10GHz) ,0.5mV(30Ghz) |
Number of sampling channels | 1~4 Channel |
Vertical System Conversion Time | Depending on the number of sampling channels, 8.75ps (30GHz) |
RMS noise (max) | 0.5mV(10GHz),1.0mV(30GHz) |
Horizontal system Waveform zoom in and zoom out observation time base | 0.5ps/div to 1ms/div |
Time interval accuracy (jitter mode) | 0.25ps(10GHz), 0.0625ps(30GHz) |
Trigger system External clock source | 100mV,155~2500MHz(10GHz), 155~622MHz(30Ghz) |
Trigger level range | ±1.0V |
trigger input range | ±1.5V |
Trigger cutoff | ±1.5V:5ms ~100ms |
Power (external power adapter) | 50Hz,5V,3A,6W |
Ambient temperature, relative humidity Operation | Temperature-20 to ~50℃ , Humidity 20% to ~80% |
storage | Temperature -40 to ~85℃ , Humidity 5% to ~90% |
Size | 235W×55H×255L (mm) |
Weight | <2Kg |
Communication, network management interface | RJ45; support 10/100Mbps Ethernet |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2009
Total Annual:
3000000-3500000
Ecer Certification:
Verified Supplier
"To do import substitution, to create national brand" is the journey that Uc Instruments is brave to climb and the goal of continuous progress. Guangzhou UC Instruments., Co. Ltd. was founded in March 2009 and has been recognized as a high-tech enterprise in Guangdong Province... "To do import substitution, to create national brand" is the journey that Uc Instruments is brave to climb and the goal of continuous progress. Guangzhou UC Instruments., Co. Ltd. was founded in March 2009 and has been recognized as a high-tech enterprise in Guangdong Province...