Payment Terms | T/T, L/C |
Supply Ability | 60 Sets per Day |
Delivery Time | 10 Days |
Packaging Details | Carton |
Product Name | NIR-1000 Dry Fluoroimmunoassay Analyser |
Work Temperature | 5-40℃ |
Net Weight | 2.0 KGS |
Touch Screen | 7" LCD Display |
Wavelength Range | 740nm |
Test Item | NIR-1000 is used cooperatively with immunofluorescence assay kits produced by WWHS |
Quality Inspection Card | 1 piece |
Quality Inspection Information Card | 1 piece |
Excitation Light Source | LED |
Test Speed | 240 times/hour |
Manufacturer | WWHS Biotech INC |
Feature | High Sensitivity, High Accuracy |
Brand Name | WWHS |
Model Number | NIR-1000 |
Certification | ISO 13485, CE |
Place of Origin | CN |
View Detail Information
Explore similar products
WWHS NIR-1000 FIA Analyzer For NT-proBNP Cardiac Detection
NIR-1000 POCT Instrument FIA Analyzer For CK-MB Cardiac Detection
FIA Dry Fluorescence Immunoassay Analyzer 740nm NIR-1000
cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 60 Sets per Day |
Delivery Time | 10 Days | Packaging Details | Carton |
Product Name | NIR-1000 Dry Fluoroimmunoassay Analyser | Work Temperature | 5-40℃ |
Net Weight | 2.0 KGS | Touch Screen | 7" LCD Display |
Wavelength Range | 740nm | Test Item | NIR-1000 is used cooperatively with immunofluorescence assay kits produced by WWHS |
Quality Inspection Card | 1 piece | Quality Inspection Information Card | 1 piece |
Excitation Light Source | LED | Test Speed | 240 times/hour |
Manufacturer | WWHS Biotech INC | Feature | High Sensitivity, High Accuracy |
Brand Name | WWHS | Model Number | NIR-1000 |
Certification | ISO 13485, CE | Place of Origin | CN |
High Light | Dry Fluorescence Immunoassay Analyzer ,Fluorescent Immunoassay Analyzer |
WWHS NIR-1000 Dry Fluorescent Immunoassay Analyser For D-Dimer Cardiac Detection
The D-Dimer Rapid Quantitative Test along with WWHS Fluorescence Immunoassay Analyzer (FIA) is intended for vitro quantitative determination of D-Dimer in human whole blood or plasma.
Description of WWHS NIR-1000 Dry Fluoroimmunoassay Analyser
High Accuracy
When the instrument tests the calibrated fluorescence test card, the deviation between the measured fluorescence value and the calibration value of the fluorescence test card is ±3.0%.
Repeatability
The variable coefficient of fluorescence value of fluorescence test cards of different intensities repeatedly measured by the instrument CV≤2.0%
WWHS Assay List
Cardiac | ||||||
cat#. | Product item | Specimen | Reaction Time | Measure Range | Clinical Range | Itended Use |
1 | cTnI | WB/Serum/Plasma | 12min. | 0.1-40ng/ml | <0.3ng/ml | several heart diseases including myocardial infarction and heart failure. |
2 | Myo | WB/Serum/Plasma | 12min. | 5-400ng/ml | <58ng/ml | acute myocardial infarction (AMI) in early stage. |
3 | CK-MB | WB/Serum/Plasma | 12min. | 1-200ng/ml | <5ng/ml | acute myocardial infarction (AMI) in early stage. |
4 | NT-proBNP | WB/Serum/Plasma | 10min. | 20-35000pg/ml | Under 75:0~347pg/mL, Over 75:0~449pg/mL | heart failure . |
5 | D-Dimer | WB/Plasma | 10min. | 40-10000ng/ml | <500ng/ml | disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc. |
6 | cTnI+Myo+CKMB | WB/Serum/Plasma | 12min. | same with single item | same with single item | Triple marker of myocardial infarction. |
7 | ST2 | WB/Serum/Plasma | 10min. | 10-400ng/ml | <35ng/ml | heart failure . |
8 | Lp-PLA2 | WB/Serum/Plasma | 10min. | 10-900ng/ml | <175ng/ml | Risk evaluation of ACS and atherosclerotic ischemic stroke patients. |
9 | S100-β | WB/Serum/Plasma | 10min. | 0.05-10ng/ml | <0.2ng/ml | Cerebral infarction, cerebral injury. |
Inflammation | ||||||
10 | CRP / hs-CRP | WB/Serum/Plasma | 3min. | 0.5-200mg/L | CRP<10mg/L,hs-CRP<1mg/L | nonspecficity inflammatory marker. |
11 | SAA | Serum | 5min. | 1-200mg/L | <10mg/L | inflammation&infection. |
12 | PCT | WB/Serum/Plasma | 10min. | 0.2-100ng/ml | <0.5ng/ml | Sepsis |
13 | CRP+SAA | WB/Serum/Plasma | 5min. | same with single item | same with single item | inflammation&infection. |
14 | IL-6 | WB/Serum/Plasma | 10min. | 5-4000pg/ml | 10pg/ml | diabetes,rheumatoid arthritis,etc |
Thyroid Hormone | ||||||
15 | TSH | Serum/Plasma | 15min. | 0.3-100mU/L | 0.35-5mU/L | hyperthyroidism and hypothyroidism |
16 | TT3 | Serum/Plasma | 15min. | 0.5-10nmol/L | 1.3-3.1nmol/L | thyroid dysfunction |
17 | TT4 | Serum/Plasma | 15min. | 5-300nmol/L | 66-181nmol/L | thyroid dysfunction |
18 | FT3 | Serum/Plasma | 15min. | 1-100pmol/L | 4-10pmol/L | thyroid dysfunction |
19 | FT4 | Serum/Plasma | 15min. | 5-300pmol/L | 19-39pmol/L | thyroid dysfunction |
Tumor Marker | ||||||
20 | AFP | Serum/Plasma | 15min. | 2.5-200ng/ml | <20ng/ml | pregnancy cancer |
21 | CEA | Serum/Plasma | 15min. | 1-200ng/ml | <5ng/ml | colon cancer, colorectal cancer,etc. |
22 | NSE | Serum/Plasma | 15min. | 1-400ng/ml | <16ng/ml | non-small cell lung cancer |
23 | FOB | fecal specimens | 10min. | 50-1000ng/ml | <100ng/ml | Abnormal recessive gastrointestinal bleeding |
24 | PG II | Serum/Plasma | 15min. | 1-100ug/L | PGI/PGII>3.0 | gastric abnormalities |
25 | PG I | Serum/Plasma | 15min. | 2.5-200ug/L | >70ng/ml | gastric abnormalities |
26 | TPSA | Serum/Plasma | 15min. | 0.5-40ng/ml | <4ng/ml | prostate cancer |
27 | FPSA | Serum/Plasma | 15min. | 0.1-10ng/ml | <1ng/ml | prostate cancer |
28 | CA12-5 | Serum/Plasma | 15min. | 20-500U/ml | <35U/ml | ovarian cancer |
29 | CA15-3 | Serum/Plasma | 15min. | 10-400U/ml | < 25 U/mL | breast cancer |
30 | HE4 | Serum/Plasma | 15min. | 50-2000pmol/L | <140 pmol/L | ovarian cancer |
31 | CA19-9 | Serum/Plasma | 15min. | 10-400U/ml | < 27 U/mL | pancreatic cancer |
32 | β-HCG | Serum/Plasma | 15min. | 5-400mIU/ml | <10 mIU/mL | Early pregrancy, ectopic HCG cancer,incomplete abortion |
33 | CK19(Cyfra21-1) | Serum/Plasma | 15min. | 0.5-50ng/ml | <2.5ng/ml | non-small cell lung cancer |
Fertility | ||||||
34 | HCG / β-HCG | Serum/Plasma | 10min. | 5-20000mIU/ml | <5 mIU/mL | early pregrancy. |
35 | AMH | Serum/Plasma | 10min. | 0.1-16ng/ml | Male: 20-60 years old, 0.92-13.89 ng/mL Female: 20-29 years old, 0.88-10.35 ng/mL 30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL | ovarian reserve level |
Gastrointestinal | ||||||
36 | FOB | fecal specimens | 10min. | qualitative | qualitative | gastrointestinal hemorrhage. |
37 | TRF | fecal specimens | 10min. | qualitative | qualitative | gastrointestinal hemorrhage. |
38 | FOB+TRF | fecal specimens | 10min. | qualitative | qualitative | gastrointestinal hemorrhage. |
Infection | ||||||
39 | C.Pneumonia | WB/Serum/Plasma | 15min. | qualitative | qualitative | CP infection |
40 | M.Pneumonia | WB/Serum/Plasma | 15min. | qualitative | qualitative | MP infection |
41 | Covid-19 Antigen | nasal swab, throat swab or nasal wash/aspirate specimens | 15min. | qualitative | qualitative | respiratory tract |
42 | Covid-19 Ab IgG/IgM | WB/Serum/Plasma | 15min. | qualitative | qualitative | respiratory tract |
43 | FluA | nasal swab, throat swab or nasal wash/aspirate specimens | 15min. | qualitative | qualitative | respiratory tract |
44 | FluB | nasal swab, throat swab or nasal wash/aspirate specimens | 15min. | qualitative | qualitative | respiratory tract |
Renal Injury | ||||||
45 | CysC | WB/Serum/Plasma | 5min. | 0.4-9mg/L | 0.5-1.1mg/L | renal function |
46 | NGAL | Urine | 10min. | 10-1500ng/mL | <132ng/mL | acute kidney injury. |
Other | ||||||
47 | FERR | Serum | 5min. | 10-500ng/ml | Male:24ng/mL~335ng/mL, Female:11ng/mL~307ng/mL | iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia |
48 | HbA1c | WB | 10min. | 4%-14% | 4%-6% | diabetes |
49 | VD | Serum/Plasma | 15min. | 8-70ng/mL | 19-57ng/mL | fetation |
Notice
1) The test card can be used only once at room temperature, do not reuse or use test card out of expiry date.
2) Return all reagents and sample into room temperature before use.
3) Be careful when prepare sample, wear glove and mask.
4) The whole blood need add anticoagulants, not frozen; serum sample can store in frozen, avoid repeated freezing and thawing.
5) This product is only for in vitro rapid diagnostic human use, can be quantified, not only qualitative testing.
6) The product test results for reference only, for confirmation, please refer to the relevant national standard methods.
Reagent Storage and expiry date
Storage: Store at 4-30 ℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months; date of production is on box.
Package and Delivery
Packing Details : Standard carton package or as demand.
Delivery Details : 5-15days after payment
We support a variety of transportation modes, including land
transportation, sea transportation, air transportation, DHL, Fedex,TNT and other international logistics express.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2016
Total Annual:
3000-5000
Employee Number:
50~80
Ecer Certification:
Site Member
As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...
Get in touch with us
Leave a Message, we will call you back quickly!