China factories

China factory - WWHS Biotech.Inc(exclusive marketed by Dawin)

WWHS Biotech.Inc(exclusive marketed by Dawin)

  • China,Shenzhen
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China NIR-1000 Dry Fluorescence Immunoassay Analyzer For D-Dimer Cardiac Detection
China NIR-1000 Dry Fluorescence Immunoassay Analyzer For D-Dimer Cardiac Detection

  1. China NIR-1000 Dry Fluorescence Immunoassay Analyzer For D-Dimer Cardiac Detection
  2. China NIR-1000 Dry Fluorescence Immunoassay Analyzer For D-Dimer Cardiac Detection

NIR-1000 Dry Fluorescence Immunoassay Analyzer For D-Dimer Cardiac Detection

  1. MOQ: 2
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 60 Sets per Day
Delivery Time 10 Days
Packaging Details Carton
Product Name NIR-1000 Dry Fluoroimmunoassay Analyser
Work Temperature 5-40℃
Net Weight 2.0 KGS
Touch Screen 7" LCD Display
Wavelength Range 740nm
Test Item NIR-1000 is used cooperatively with immunofluorescence assay kits produced by WWHS
Quality Inspection Card 1 piece
Quality Inspection Information Card 1 piece
Excitation Light Source LED
Test Speed 240 times/hour
Manufacturer WWHS Biotech INC
Feature High Sensitivity, High Accuracy
Brand Name WWHS
Model Number NIR-1000
Certification ISO 13485, CE
Place of Origin CN

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 60 Sets per Day
Delivery Time 10 Days Packaging Details Carton
Product Name NIR-1000 Dry Fluoroimmunoassay Analyser Work Temperature 5-40℃
Net Weight 2.0 KGS Touch Screen 7" LCD Display
Wavelength Range 740nm Test Item NIR-1000 is used cooperatively with immunofluorescence assay kits produced by WWHS
Quality Inspection Card 1 piece Quality Inspection Information Card 1 piece
Excitation Light Source LED Test Speed 240 times/hour
Manufacturer WWHS Biotech INC Feature High Sensitivity, High Accuracy
Brand Name WWHS Model Number NIR-1000
Certification ISO 13485, CE Place of Origin CN
High Light Dry Fluorescence Immunoassay AnalyzerFluorescent Immunoassay Analyzer

WWHS NIR-1000 Dry Fluorescent Immunoassay Analyser For D-Dimer Cardiac Detection

 

The D-Dimer Rapid Quantitative Test along with WWHS Fluorescence Immunoassay Analyzer (FIA) is intended for vitro quantitative determination of D-Dimer in human whole blood or plasma.

 

Description of WWHS NIR-1000 Dry Fluoroimmunoassay Analyser

High Accuracy

When the instrument tests the calibrated fluorescence test card, the deviation between the measured fluorescence value and the calibration value of the fluorescence test card is ±3.0%.

Repeatability

The variable coefficient of fluorescence value of fluorescence test cards of different intensities repeatedly measured by the instrument CV≤2.0%

 

WWHS Assay List

 

Cardiac          
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
1 cTnI WB/Serum/Plasma 12min. 0.1-40ng/ml <0.3ng/ml several heart diseases including myocardial infarction and heart failure.
2 Myo WB/Serum/Plasma 12min. 5-400ng/ml <58ng/ml acute myocardial infarction (AMI) in early stage.
3 CK-MB WB/Serum/Plasma 12min. 1-200ng/ml <5ng/ml acute myocardial infarction (AMI) in early stage.
4 NT-proBNP WB/Serum/Plasma 10min. 20-35000pg/ml Under 75:0~347pg/mL,
Over 75:0~449pg/mL
heart failure .
5 D-Dimer WB/Plasma 10min. 40-10000ng/ml <500ng/ml disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
6 cTnI+Myo+CKMB WB/Serum/Plasma 12min. same with single item same with single item Triple marker of myocardial infarction.
7 ST2 WB/Serum/Plasma 10min. 10-400ng/ml <35ng/ml heart failure .
8 Lp-PLA2 WB/Serum/Plasma 10min. 10-900ng/ml <175ng/ml Risk evaluation of ACS and atherosclerotic ischemic stroke patients.
9 S100-β WB/Serum/Plasma 10min. 0.05-10ng/ml <0.2ng/ml Cerebral infarction, cerebral injury.
Inflammation          
10 CRP / hs-CRP WB/Serum/Plasma 3min. 0.5-200mg/L CRP<10mg/L,hs-CRP<1mg/L nonspecficity inflammatory marker.
11 SAA Serum 5min. 1-200mg/L <10mg/L inflammation&infection.
12 PCT WB/Serum/Plasma 10min. 0.2-100ng/ml <0.5ng/ml Sepsis
13 CRP+SAA WB/Serum/Plasma 5min. same with single item same with single item inflammation&infection.
14 IL-6 WB/Serum/Plasma 10min. 5-4000pg/ml 10pg/ml diabetes,rheumatoid arthritis,etc
Thyroid Hormone          
15 TSH Serum/Plasma 15min. 0.3-100mU/L 0.35-5mU/L hyperthyroidism and hypothyroidism
16 TT3 Serum/Plasma 15min. 0.5-10nmol/L 1.3-3.1nmol/L thyroid dysfunction
17 TT4 Serum/Plasma 15min. 5-300nmol/L 66-181nmol/L thyroid dysfunction
18 FT3 Serum/Plasma 15min. 1-100pmol/L 4-10pmol/L thyroid dysfunction
19 FT4 Serum/Plasma 15min. 5-300pmol/L 19-39pmol/L thyroid dysfunction
Tumor Marker          
20 AFP Serum/Plasma 15min. 2.5-200ng/ml <20ng/ml pregnancy cancer
21 CEA Serum/Plasma 15min. 1-200ng/ml <5ng/ml colon cancer, colorectal cancer,etc.
22 NSE Serum/Plasma 15min. 1-400ng/ml <16ng/ml non-small cell lung cancer
23 FOB fecal specimens 10min. 50-1000ng/ml <100ng/ml Abnormal recessive gastrointestinal bleeding
24 PG II Serum/Plasma 15min. 1-100ug/L PGI/PGII>3.0 gastric abnormalities
25 PG I Serum/Plasma 15min. 2.5-200ug/L >70ng/ml gastric abnormalities
26 TPSA Serum/Plasma 15min. 0.5-40ng/ml <4ng/ml prostate cancer
27 FPSA Serum/Plasma 15min. 0.1-10ng/ml <1ng/ml prostate cancer
28 CA12-5 Serum/Plasma 15min. 20-500U/ml <35U/ml ovarian cancer
29 CA15-3 Serum/Plasma 15min. 10-400U/ml < 25 U/mL breast cancer
30 HE4 Serum/Plasma 15min. 50-2000pmol/L <140 pmol/L ovarian cancer
31 CA19-9 Serum/Plasma 15min. 10-400U/ml < 27 U/mL pancreatic cancer
32 β-HCG Serum/Plasma 15min. 5-400mIU/ml <10 mIU/mL Early pregrancy, ectopic HCG cancer,incomplete abortion
33 CK19(Cyfra21-1) Serum/Plasma 15min. 0.5-50ng/ml <2.5ng/ml non-small cell lung cancer
Fertility          
34 HCG / β-HCG Serum/Plasma 10min. 5-20000mIU/ml <5 mIU/mL early pregrancy.
35 AMH Serum/Plasma 10min. 0.1-16ng/ml Male: 20-60 years old, 0.92-13.89 ng/mL
Female: 20-29 years old, 0.88-10.35 ng/mL
30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL
ovarian reserve level
Gastrointestinal            
36 FOB fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
37 TRF fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
38 FOB+TRF fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
Infection            
39 C.Pneumonia WB/Serum/Plasma 15min. qualitative qualitative CP infection
40 M.Pneumonia WB/Serum/Plasma 15min. qualitative qualitative MP infection
41 Covid-19 Antigen nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
42 Covid-19 Ab IgG/IgM WB/Serum/Plasma 15min. qualitative qualitative respiratory tract
43 FluA nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
44 FluB nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
Renal Injury            
45 CysC WB/Serum/Plasma 5min. 0.4-9mg/L 0.5-1.1mg/L renal function
46 NGAL Urine 10min. 10-1500ng/mL <132ng/mL acute kidney injury.
Other            
47 FERR Serum 5min. 10-500ng/ml Male:24ng/mL~335ng/mL,
Female:11ng/mL~307ng/mL
iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia
48 HbA1c WB 10min. 4%-14% 4%-6% diabetes
49 VD Serum/Plasma 15min. 8-70ng/mL 19-57ng/mL fetation

 

 

 

 

Notice

 

1) The test card can be used only once at room temperature, do not reuse or use test card out of expiry date.

2) Return all reagents and sample into room temperature before use.

3) Be careful when prepare sample, wear glove and mask.

4) The whole blood need add anticoagulants, not frozen; serum sample can store in frozen, avoid repeated freezing and thawing.

5) This product is only for in vitro rapid diagnostic human use, can be quantified, not only qualitative testing.

6) The product test results for reference only, for confirmation, please refer to the relevant national standard methods.

 

Reagent Storage and expiry date

 

Storage: Store at 4-30 ℃ in dark, sealed, dry place, no frozen.

Expiry date: 12 months; date of production is on box.


Package and Delivery

 

Packing Details : Standard carton package or as demand.
Delivery Details : 5-15days after payment

We support a variety of transportation modes, including land

transportation, sea transportation, air transportation, DHL, Fedex,TNT and other international logistics express.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2016

  • Total Annual:

    3000-5000

  • Employee Number:

    50~80

  • Ecer Certification:

    Site Member

As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...

+ Read More

Get in touch with us

  • Reach Us
  • WWHS Biotech.Inc(exclusive marketed by Dawin)
  • Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
  • https://www.fiapoct.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement