Payment Terms | T/T |
Supply Ability | 30000 Kits per Week |
Delivery Time | 7 Days |
Packaging Details | Colorful Paper Box |
Prodcut Name | C.Pneumonia Rapid Test Kit |
Type | One Step Assay |
Reactivity | Human |
Formal Name | Chlamydia Pneumoniae IgM |
Storage | At Room Temperature |
Pack | 20 Test |
Usage | Infection |
Advantage | High Accurate |
Brand Name | WWHS |
Model Number | C.Pneumonia |
Certification | CE |
Place of Origin | CN |
View Detail Information
Explore similar products
FIA Real Time PCR Kits Thyroid Stimulating Hormone TSH Test Kit
Total Triiodothyronine T3 Real Time PCR Kits One Step Assay Room Temperature
Wide Range Diagnostics PSA Rapid Test Kit POCT IVD Tumor Marker Detection
CEA Real Time PCR Kits High Accuracy 25 Vials Sample For Tumor Detection
Product Specification
Payment Terms | T/T | Supply Ability | 30000 Kits per Week |
Delivery Time | 7 Days | Packaging Details | Colorful Paper Box |
Prodcut Name | C.Pneumonia Rapid Test Kit | Type | One Step Assay |
Reactivity | Human | Formal Name | Chlamydia Pneumoniae IgM |
Storage | At Room Temperature | Pack | 20 Test |
Usage | Infection | Advantage | High Accurate |
Brand Name | WWHS | Model Number | C.Pneumonia |
Certification | CE | Place of Origin | CN |
C.Pneumonia Immunoassay System IVD Rapid Test Kit IFA and Colloidal Gold Diagnostic WWHS Reagent Cassette
Intended Use
Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae is a colloidal gold immunochromatographic assay for the qualitative determination of IgM Antibody to Chlamydia Pneumoniae (Cpn-IgM) in human whole blood,serum or plasma, it acts as chlamydia pneumonia infection auxiliary diagnosis reagent in clinical diagnosis. Meanwhile it is a screening reagent. All positive sample must be confirmed by other methodologies.This test is intended for healthcare professional use only.
About NIR-1000 Dry Fluoroimmunoassay Analyser
It is a fluorescence immunochromatographic analysing system with internal temperature control, which can help diagnose conditions such as infection, diabetes, cardiovascular diseases, renal injury and cancers, etc.
* Immunofluorescence technology
* Testing time less than 15 minutes
* Easy-to-use touch-screen platform,multi-language system
* Reagents stored at room temperature for 12 months
* Dry immune technology, maintenance free
Smarter Operation
1. High Quality: Imported Major Components with Importing Advanced Technology
2. User-Friendly Design: 7 Inch touch screen, great touch feeling, simple graphic
interface
3. Built-In Lithium Battery: High Mobility for first aid&amulance
4. Two Test Mode: Internal&External mode for different clinical needs
5. Smart Report: Auto Printing
6. Visual Results: Able to connect with LIH/HIS
Note:
1) Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in
result. Each user should obtain their own standard curve.
2) If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
3) If specimens generate values higher than the highest standard, dilute the specimens and repeat the assay
WWHS Inflammation Assay List
cat#. | Product item | Specimen | Reaction Time | Measure Range | Clinical Range | Itended Use |
10 | CRP / hs-CRP | WB/Serum/Plasma | 3min. | 0.5-200mg/L | CRP<10mg/L,hs-CRP<1mg/L | nonspecficity inflammatory marker. |
11 | SAA | Serum | 5min. | 1-200mg/L | <10mg/L | inflammation&infection. |
12 | PCT | WB/Serum/Plasma | 10min. | 0.2-100ng/ml | <0.5ng/ml | Sepsis |
13 | CRP+SAA | WB/Serum/Plasma | 5min. | same with single item | same with single item | inflammation&infection. |
14 | IL-6 | WB/Serum/Plasma | 10min. | 5-4000pg/ml | 10pg/ml | diabetes,rheumatoid arthritis,etc |
Quality Control
A procedural control is included in the test. A colored line appearing in the control region (C) is the internal procedural
control. It confirms sufficient specimen volume and correct procedural technique.
Control standards are not supplied with this kit; however, it is recommended that a positive control and a negative control control be tested as a good laboratory practice to confirm the test procedure and to verify proper test performance.
F
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2016
Total Annual:
3000-5000
Employee Number:
50~80
Ecer Certification:
Site Member
As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...
Get in touch with us
Leave a Message, we will call you back quickly!