Payment Terms | L/C, T/T |
Supply Ability | 20000 Kits per Week |
Delivery Time | 7 Days |
Packaging Details | Colorful Paper Box |
Product Name | NT-proBNP Rapid Test Kit |
Storage | Room Temperature |
Sample Buffer | 25 Vials |
Manufacturer | WWHS BIOTECH INC |
Type | One Step Assay |
Application | Human |
Advantage | High Accuracy |
Format | Cassette |
Throughput | 3000 Tests/Day |
Formal Name | N-terminal prohormone of brain natriuretic peptide |
Annual Capacity | 5 Million a year |
Keywords | High Stability, High Sensitivity |
Brand Name | WWHS |
Certification | ISO 13485, CE |
Place of Origin | CN |
Model Number | NT-proBNP |
View Detail Information
Explore similar products
WWHS SARS-CoV-2 Antigen FIA Rapid Quantitative Test Kit POCT Assay
Ca125 Rapid Quantitative Test Kit Fluorescence Immunoassay Tumor Maker
FIA Quantitative PSA Rapid Test Kit Dry Fluoroimmunoassay Analyser
CYFRA21-1 Colloidal Gold POCT FIA Rapid Test Kit CE Approved IVD Assay
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 20000 Kits per Week |
Delivery Time | 7 Days | Packaging Details | Colorful Paper Box |
Product Name | NT-proBNP Rapid Test Kit | Storage | Room Temperature |
Sample Buffer | 25 Vials | Manufacturer | WWHS BIOTECH INC |
Type | One Step Assay | Application | Human |
Advantage | High Accuracy | Format | Cassette |
Throughput | 3000 Tests/Day | Formal Name | N-terminal prohormone of brain natriuretic peptide |
Annual Capacity | 5 Million a year | Keywords | High Stability, High Sensitivity |
Brand Name | WWHS | Certification | ISO 13485, CE |
Place of Origin | CN | Model Number | NT-proBNP |
High Light | NT-proBNP POCT Test Kit ,20T POCT Test Kit ,NT-proBNP Rapid Quantitative Test Kit |
【Product name】
N-terminal prohormone of brain natriuretic peptide (NT-proBNP) Rapid Quantitative Test(Fluorescence immunoassay)
【Package specification】
25 Tests/kit
【Intended use】
This kit is used for quantitative determination of N-terminal prohormone of brain natriuretic peptide (NT-proBNP) in human whole blood and plasma.
【Inspection principle】
The principle of immunofluorescence chromatography was applied to the kit. The NT-proBNP antigen in the sample was first bound with the conjugated compound of fluorescent labeled NT-proBNP monoclonal antibody, then moved and combined with another NT-proBNP monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.
【Main components】
Name | Quantity | Component |
Test card | 25 | It is composed of fluorescent pad (coated with fluorescent labeled N-terminal prohormone of brain natriuretic peptide (NT-proBNP) monoclonal mouse antibody), nitrocellulose membrane (coated with N-terminal prohormone of brain natriuretic peptide (NT-proBNP) monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing |
Sample buffer | 25(300μL/tube) | Phosphate buffer |
ID card | 1 | Record the standard curve information of this kit |
The components in different batches of kits cannot be used interchangeably.
【Storage conditions and validity】
The test card should be stored at 4℃~30℃, dry, dark and no freezing. It should be stored in sealed aluminum foil bag and valid for 18 months. The test card should be returned to room temperature (15℃~30℃) before opening. It should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.
The production date, batch number and expiration date are shown in the outer package of the product.
【Applicable instruments】
NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.
【Sample requirements】
【Test procedure】
【Reference interval】
Healthy subjects under 75 years old have assay values below 347pg/mL. Healthy subjects over 75 years old have assay values below 449pg/mL.
【Interpretation of results】
【Limitations of methods】
【Performance】
1. Analysis sensitivity
No more than 18pg/mL.
2. Accuracy
The relative deviation from the target value is within ±10%.
3. Precision
The within and between assay coefficient of variations are within 15%.
4. Linear range
Within the linear range (20-35000pg/mL), the linear correlation coefficient R≥0.990.
【Note】
1. This kit is only used for in vitro diagnosis.
2. The test card and sample diluent are disposable and cannot be reused.
3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃~30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.
4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.
5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.
WWHS Assay list | Cardiac | |||||
cat#. | Product Item | Specimen | Reaction Time | Measure Range | Clinical Range | Intended Use |
1 | cTnI | WB/Serum/Plasma | 12min. | 0.1-40ng/ml | <0.3ng/ml | several heart diseases including myocardial infarction and heart failure. |
2 | Myo | WB/Serum/Plasma | 12min. | 5-400ng/ml | <58ng/ml | acute myocardial infarction (AMI) in early stage. |
3 | CK-MB | WB/Serum/Plasma | 12min. | 1-200ng/ml | <5ng/ml | acute myocardial infarction (AMI) in early stage. |
4 | NT-proBNP | WB/Serum/Plasma | 10min. | 20-35000pg/ml | Under 75:0~347pg/mL, Over 75:0~449pg/mL | heart failure . |
5 | D-Dimer | WB/Plasma | 10min. | 40-10000ng/ml | <500ng/ml | disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc. |
6 | cTnI+Myo+CKMB | WB/Serum/Plasma | 12min. | same with single item | same with single item | Triple marker of myocardial infarction. |
7 | ST2 | WB/Serum/Plasma | 10min. | 10-400ng/ml | <35ng/ml | heart failure . |
8 | Lp-PLA2 | WB/Serum/Plasma | 10min. | 10-900ng/ml | <175ng/ml | Risk evaluation of ACS and atherosclerotic ischemic stroke patients. |
9 | S100-β | WB/Serum/Plasma | 10min. | 0.05-10ng/ml | <0.2ng/ml | Cerebral infarction, cerebral injury. |
Interpretation of Test Results
1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.
2. For samples whose cTnI concentration is lower than 0.1ng/mL and higher than 40ng/mL, test result is “<0.1ng/mL” and “>40ng/mL” respectively.
Notice
1) The test card can be used only once at room temperature, do not reuse or use test card out of expiry date.
2) Return all reagents and sample into room temperature before use.
3) Be careful when prepare sample, wear glove and mask.
4) The whole blood need add anticoagulants, not frozen; serum sample can store in frozen, avoid repeated freezing and thawing.
5) This product is only for in vitro rapid diagnostic human use, can be quantified, not only qualitative testing.
6) The product test results for reference only, for confirmation, please refer to the relevant national standard methods.
FAQ
1. What is fluorescent immunoassay analyzer?
The Biopanda Fluorescence Immunoassay Analyser is used by small labs for the detection of a range of biomarkers to assist with the diagnosis and monitoring of several medical conditions including cardiovascular disease, inflammation, kidney disease, thyroid conditions, and fertility.
2. Do you have CE certificate for immunoassay analyzer?
WBC analyzer belongs to IVD other/general, no need CE, Ec declaration is enough.
3. How does fluorescence immunoassay work?
Fluorescent Immunoassays are simply a different type of immunoassay. ... A modern fluorescent based immunoassay uses as the detection reagent a fluorescent compound which absorbs light or energy (excitation energy) at a specific wavelength and then emits light
or energy at a different wavelength.
4. What is indirect immunofluorescence assay?
Indirect immunofluorescence, or secondary immunofluorescence, is a technique used in laboratories to detect circulating autoantibodies in patient serum. It is used to diagnose autoimmune blistering diseases.
5. Is immunofluorescence an immunoassay?
Immunofluorescence assay (IFA) is a standard virologic technique to identify the presence of antibodies by their specific ability to react with viral antigens expressed in infected cells; bound antibodies are visualized by incubation with fluorescently labeled antihuman antibody.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2016
Total Annual:
3000-5000
Employee Number:
50~80
Ecer Certification:
Site Member
As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...
Get in touch with us
Leave a Message, we will call you back quickly!