China factories

China factory - WWHS Biotech.Inc(exclusive marketed by Dawin)

WWHS Biotech.Inc(exclusive marketed by Dawin)

  • China,Shenzhen
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic
China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic

  1. China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic
  2. China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic
  3. China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic
  4. China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic
  5. China High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic

High Accurate POCT Test Kit IL-6 FIA Rapid Quantitative Test Kit Diagnostic

  1. MOQ: 1000
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 20000 Kits per Week
Delivery Time 7 Days
Packaging Details Colorful Paper Box
Product Name IL-6 Rapid Quantitative Test Kit
Storage Room Temperature
Sample Buffer 25 Vials
Manufacturer WWHS BIOTECH INC
Type One Step Assay
Application Human
Advantage High Accurate
Format Cassette
Feature High Sensitivity, High Stability
Production Capacity 5 Million a Year
Brand Name WWHS
Certification ISO 13485, CE
Place of Origin CN
Model Number IL-6

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 20000 Kits per Week
Delivery Time 7 Days Packaging Details Colorful Paper Box
Product Name IL-6 Rapid Quantitative Test Kit Storage Room Temperature
Sample Buffer 25 Vials Manufacturer WWHS BIOTECH INC
Type One Step Assay Application Human
Advantage High Accurate Format Cassette
Feature High Sensitivity, High Stability Production Capacity 5 Million a Year
Brand Name WWHS Certification ISO 13485, CE
Place of Origin CN Model Number IL-6
High Light High Accurate POCT Test KitFIA POCT Test KitIL-6 Rapid Quantitative Test Kit

【Product name】

Diagnostic Kit for Interleukin-6(Immunochromatographic assay)

 

【Packing specification】

25 Tests/kit

 

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescently-labeled IL-6 monoclonal antibody), nitrocellulose membrane (coated with IL-6 monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing.
Sample diluent 25 (0.3mL/ tube) Phosphate buffer
ID card 1 With specific stand curve file

The components in different batches of kits cannot be used interchangeably.

 

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

 

【Test procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the ID card. The test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 100 µL of patient sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

【Performance】

1. Limits of detection

No higher than 5.00 pg/mL.

2. Accuracy

The relative deviation from the target value is limited to ±15.0%.

3. Repeatability

The within and between assay coefficient of variations are within 15.0%.

4. Linearity range

Within the linear range (5.00~ 4000.00)ng/mL, the linear correlation coefficient R≥0.990.

 

【Note】

1. The kit can be used for in vitro diagnosis only.

2. Test card and buffer solution are single-use and they cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.

5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.

6. The kit used should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.

 

 

WWHS Assay list  Inflammation        
cat#. Product Item Specimen Reaction Time Measure Range Clinical Range Intended Use
10 CRP / hs-CRP WB/Serum/Plasma 3min. 0.5-200mg/L CRP<10mg/L,hs-CRP<1mg/L nonspecficity inflammatory marker.
11 SAA Serum 5min. 1-200mg/L <10mg/L inflammation&infection.
12 PCT WB/Serum/Plasma 10min. 0.2-100ng/ml <0.5ng/ml Sepsis
13 CRP+SAA WB/Serum/Plasma 5min. same with single item same with single item inflammation&infection.
14 IL-6 WB/Serum/Plasma 10min. 5-4000pg/ml 10pg/ml diabetes,rheumatoid arthritis,etc

 

 

Interpretation of Test Results


1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.
2. For samples whose cTnI concentration is lower than 0.1ng/mL and higher than 40ng/mL, test result is “<0.1ng/mL” and “>40ng/mL” respectively.

 

 

Manual of WWHS POCT Test Kit Procedure


1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
2. Start Nir-1000 dry fluorescence immunoassay analyzer according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
4. Place the test card on a clean horizontal table and mark it horizontally.

 

WWHS NIR-1000 Smarter Operation

 

1. High Quality: Imported Major Components with Advanced German Technology

2.User-Friendly Design: 7 Inch touch screen, great touch feeling, simple graphic interface

3. Built-In Lithium Battery: High Mobility for first aid&amulance

4. Two Test Mode: Internal&External mode for different clinical needs

5. Smart Report: Auto Printing

6. Visual Results: Able to connect with LIH/HIS

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2016

  • Total Annual:

    3000-5000

  • Employee Number:

    50~80

  • Ecer Certification:

    Site Member

As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...

+ Read More

Get in touch with us

  • Reach Us
  • WWHS Biotech.Inc(exclusive marketed by Dawin)
  • Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
  • https://www.fiapoct.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement