Payment Terms | T/T |
Supply Ability | 20000 Kits per Week |
Delivery Time | 7 Days |
Packaging Details | Colorful Paper Box |
Warranty | 12 Months |
Application | Clinical Laboratory, ICU, Emergency Dept, Cardiology |
Reaction Time | 12 Minutes |
Manufacturer | WWHS Biotech INC |
Advantage | High Sensitivity |
Keywords | High Stability, High Sensitivity, High Accuracy |
Annual Capacity | 3 Million a year |
Format | Cassette |
Brand Name | WWHS |
Model Number | CK-MB |
Certification | CE |
Place of Origin | CN |
View Detail Information
Explore similar products
DD D-Dimer Rapid Quantitative Test , Blood Rapid Diagnostic Test Kit
CE NT-proBNP Rapid Test Kit IFA Colloidal Gold IVD Diagnostic
cTnI Cardiac Troponin I Rapid Test Kit For Dry Fluoroimmunoassay Analyser
High Accurate ST2 FIA Rapid Quantitative Test Kit POCT 20T Assay
Product Specification
Payment Terms | T/T | Supply Ability | 20000 Kits per Week |
Delivery Time | 7 Days | Packaging Details | Colorful Paper Box |
Warranty | 12 Months | Application | Clinical Laboratory, ICU, Emergency Dept, Cardiology |
Reaction Time | 12 Minutes | Manufacturer | WWHS Biotech INC |
Advantage | High Sensitivity | Keywords | High Stability, High Sensitivity, High Accuracy |
Annual Capacity | 3 Million a year | Format | Cassette |
Brand Name | WWHS | Model Number | CK-MB |
Certification | CE | Place of Origin | CN |
High Light | CK-MB Rapid Quantitative Test Kit ,High Sensitivity CK MB Test Kit ,FIA POCT CK MB Test Kit |
CK-MB Rapid Quantitative Test Kit WWHS FIA POCT Fluorescence Immunoassay
【Product name】
Creatine Kinase Isoenzyme MB (CK-MB) Rapid Quantitative Test (Fluorescence immunoassay)
【Packing specification】
25 Tests/kit
【Components】
Name | Quantity | Component |
Test cards | 25 | It is composed of fluorescent pad (coated with fluorescently-labeled CK-MB monoclonal mouse antibody), nitrocellulose membrane (coated with CK-MB monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing |
Sample diluent | 25 | Phosphate buffer |
ID card | 1 | With specific stand curve file |
The components in different batches of CK-MB Rapid Quantitative Test Kits cannot be used interchangeably.
【Applicable instrument】
Mod:NIR-1000 Dry Fluoroimmunoassay Analyser produced by WWHS Biotech.Inc.
【Sample requirements】
1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃ for 30 days.
4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.
【Reference interval】
The normal reference value is less than 5ng/mL in this assay. It is strongly recommended that each laboratory should determine its own normal and abnormal values.
【Limitation of rest method】
1. CK-MB Rapid Quantitative Test Kit is only used to detect human plasma/ serum and whole blood samples.
2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
3. The content of triglyceride in the sample shall not exceed 10mg/mL, the content of hemoglobin shall not exceed 10mg/mL, and the content of bilirubin shall not exceed 0.5mg/mL, and the relative deviation of the test results shall not exceed ±15%.
4. When the concentration of CK-MB in the sample is less than 300.00ng/mL ,there is no hook effect.
5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
6. When RF concentration of samples is less than 2000IU/mL, relative deviation of test result is limited to ±10.0%.
【Precautions】
1. CK-MB Rapid Quantitative Test Kit can be used for in vitro diagnosis only.
2. Test card and buffer solution are single-use and they cannot be reused.
3. Please check the integrity and validity of the CK-MB Rapid Quantitative Test Kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.
4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place CK-MB Rapid Quantitative Test Kit in the air for a long time to avoid dampness.
5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.
6. CK-MB Rapid Quantitative Test Kit used should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2016
Total Annual:
3000-5000
Employee Number:
50~80
Ecer Certification:
Site Member
As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...
Get in touch with us
Leave a Message, we will call you back quickly!