China ST2 Rapid Test Kits Used To Evaluate The Prognosis And Clinical Diagnosis Of
China ST2 Rapid Test Kits Used To Evaluate The Prognosis And Clinical Diagnosis Of

  1. China ST2 Rapid Test Kits Used To Evaluate The Prognosis And Clinical Diagnosis Of
  2. China ST2 Rapid Test Kits Used To Evaluate The Prognosis And Clinical Diagnosis Of

ST2 Rapid Test Kits Used To Evaluate The Prognosis And Clinical Diagnosis Of

  1. MOQ: 1000
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 50000 Kits per Week
Delivery Time 7 Days
Packaging Details Colorful Paper Box
Product Name ST2 Rapid Test Kit
Manufacturer WWHS Biotech INC
Package 25 Test
Storage 4-30℃
Reactivity Human
Application In WWHS NIR-1000
Advantage High Sensitivity
Feature High Accuracy
Formal Name Soluble Growth Stimlating Gene 2 Protein
Keywords High Stability
Brand Name WWHS
Model Number ST-2
Certification CE
Place of Origin CN

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 50000 Kits per Week
Delivery Time 7 Days Packaging Details Colorful Paper Box
Product Name ST2 Rapid Test Kit Manufacturer WWHS Biotech INC
Package 25 Test Storage 4-30℃
Reactivity Human Application In WWHS NIR-1000
Advantage High Sensitivity Feature High Accuracy
Formal Name Soluble Growth Stimlating Gene 2 Protein Keywords High Stability
Brand Name WWHS Model Number ST-2
Certification CE Place of Origin CN
High Light 25 Test ST2 Rapid Test Kits25 Tests/kit ST2 Rapid Test Kits

    【Product name】 ST2.pdf
       Diagnostic Kit for growth STimulation expressed gene 2(Immunochromatographic assay)
     【Package specification】
       25 Tests/kit
     【Intended use】

This kit is used for quantitative determination of ST2 in human whole blood, plasma and serum.
It is used to evaluate the prognosis and clinical diagnosis of patients with chronic heart failure.

【Test principle】
The ST2 Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of ST2. The ST2 antigen in the sample was first bound with the conjugated compound of fluorescent labeled ST2 monoclonal antibody, then moved and combined with another ST2 monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.
 【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescent labeled ST2 monoclonal antibody), nitrocellulose membrane (coated with ST2 monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25(400μL/tube) Phosphate buffer
ID card 1 With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.
 
【Storage conditions and validity】
The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.
The production date, batch number and expiration date are shown in the outer package of the product.
 
【Applicable instruments】
NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc
 
【Sample requirements】

  1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
  2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
  3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
  4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

 
【Test procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser and correctly select the corresponding sample type on the instrument.
  3. Take out the ID card, make sure that the batch number of the ID card is consistent with that of the test card, and insert the ID card into the ID card port of the instrument.
  4. Take out the test card from the aluminum foil bag and use it within 15 minutes.
  5. Place the test card on a clean horizontal table and mark it horizontally.
  6. Mix 100 µL of sample with 400µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  7. At 10 minutes after addition of samples, insert the test card into NIR-1000 dry fluoroimmunoassay analyser and click the “Instant test” button to read the results.

 
【Reference interval】
Healthy non-pregnant adults are expected to have serum ST2 values below 35.00ng/mL. It is strongly recommended that each laboratory should determine its own normal and abnormal values based on population.
 
【Interpretation of results】

  1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
  2. For samples with ST2 concentration lower than 10.00ng/mL and higher than 400.00ng/mL, the detection results are reported as "<10.00ng/mL" and "> 400.00ng/mL", respectively.

 

【Limitations of methods】

  1. This kit is only used to detect human plasma/whole blood samples
  2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
  3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
  4. When the concentration of ST2 in the sample is less than 4000ng/mL, there is no hook effect.
  5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
  6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

 

 

 
 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2016

  • Total Annual:

    3000-5000

  • Employee Number:

    50~80

  • Ecer Certification:

    Site Member

As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...

+ Read More

Get in touch with us

  • Reach Us
  • WWHS Biotech.Inc(exclusive marketed by Dawin)
  • Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
  • https://www.fiapoct.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement