Payment Terms | L/C, T/T, Western Union |
Supply Ability | 5000pcs per week |
Delivery Time | 7days |
Packaging Details | 120pcs per carton |
Standard | EN60898(IEC60898)IEC60947-2 |
Rated Voltage | 400V4P |
Rated current | 3/6/10/16/20/25/32/40/50/63A |
Rated Breaking Capacity | 10KA IEC60898(0.5~63A) |
Characteristic Curve | B,C,D |
Nominal Frequency | 50/60HZ |
Max Operating Voltage | >400VAC |
Insulation Voltage | >6KV |
Uimp | >10KA |
Mechanical Life | Not less than 20000 times |
Brand Name | FEEO |
Model Number | FE7-63 |
Certification | CE/CCC/RoHS |
Place of Origin | China |
View Detail Information
Explore similar products
short circuit protection IP20 63A AC Circuit Breaker
mcb Overload Protection Uimp 10KA 400V 2P AC Circuit Breaker
IEC60898 Standard 400V 3P IP20 PV Circuit Breaker
Electrical Life 6000 Times 415V 4P AC Circuit Breaker
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 5000pcs per week |
Delivery Time | 7days | Packaging Details | 120pcs per carton |
Standard | EN60898(IEC60898)IEC60947-2 | Rated Voltage | 400V4P |
Rated current | 3/6/10/16/20/25/32/40/50/63A | Rated Breaking Capacity | 10KA IEC60898(0.5~63A) |
Characteristic Curve | B,C,D | Nominal Frequency | 50/60HZ |
Max Operating Voltage | >400VAC | Insulation Voltage | >6KV |
Uimp | >10KA | Mechanical Life | Not less than 20000 times |
Brand Name | FEEO | Model Number | FE7-63 |
Certification | CE/CCC/RoHS | Place of Origin | China |
High Light | 400VAC 4P Solar Circuit Breaker ,400VAC Solar Circuit Breaker ,400VAC 4P Surge Circuit Breaker |
FE7-63 IP20 10KA IEC60898 230V-400V AC Circuit Breaker
FE7-63 have protective function as overload,
and are used in lighting distribution system in industry commerce and dwelling, and protect fractional electric motors.
And they also have many merits of high protective grade(up to IP20), high breaking capacity, reliable sensitive, action
convenient, multi pole assembling, long life ect.
The are mainly adapted to the circuit of AC 50Hz, 250V in single pole, 415V in double, three, four poles
for protecting overload and short circuit. Mean while,
they are also used in turning on or off the electric apparatus and lighting circuit under the normal conditions.
Specifications
Standard | EN60898 (IEC60898) / IEC60947-2 |
Rated Voltage | 230V/400V AC (1P) , 400V AC (2P,3P,4P) |
Rated Current | 3,6,10,16,20,25,32,40,50,63 |
Rated Breaking Capacity | 10KA IEC60898 (3~63A) |
Characteristic Curve | B,C,D |
Max Fuse That Can Be Connected To | 100AGL (>10KA) |
Selective Grade | 3 |
Working Ambient Temperature | -5℃~+40℃ |
Enclosed Protective Class | IP20 |
Nominal Frequency | 50/60HZ |
Maximum Operating Voltage (Ue) | ≥400V AC |
Insulation Voltage (Ui) | ≥6KV |
Voltage Testing Pulse (Uimp) | ≥10KA |
Maximum Cutting Capacity (Icu) | ≥10KA |
Electrical Life | Not less than 8000 times |
Mechanical Life | Not less than 20000 times |
Dimensions
Over current tripping characteristic
Item | Model | Rated Current(A) | Initial State | Test Current | Limited Time | Limited Time | Remark |
a | B,C,D | 1~63 | Cold State | 1.13In | t 1h | Non-tripping | |
b | B,C,D | 1~63 | Immediately after the previous test | 1.45In | t<1h | Tripping | The current rise steadily to a fixed value within 5s |
c | B,C,D | In≤32 | Cold State | 2.55In | 1s<t<60s | Tripping | |
In 32 | Cold State | 2.55In | 1s<t<120s | Tripping | |||
B | 1~63 | Cold State | 3In | t≤0.1s | Non-tripping | ||
5In | t<0.1s | Tripping | |||||
C | 5In | t≤0.1s | Non-tripping | ||||
10In | t<0.1s | Tripping | |||||
D | 10In | t≤0.1s | Non-tripping | ||||
10In | t<01s | Tripping |
Characteristics Curve
Current correction values used at different ambient temperatures
Current correction factor used at different altitudes
Rated Current (A) | Different altitude correction factors | ||
≤2000m | 2000m~3000m | >3000m | |
3,6,10,16,20,25,32,40,50,63 | 1.0 | 0.9 | 0.8 |
Wire Connection Terminals
Rated Current In(A) | Copper Wire Nominal Cross Sectional Area (mm) |
3,6 | 1 |
10 | 1.5 |
16,20 | 2.5 |
25 | 4 |
32 | 6 |
48 | 10 |
63 | 10 |
Accessories
Application
Item | Code | Application | Standard |
Auxiliary Contacts | OF | Offer auxiliary signal control auxiliary circuit | IEC60947-5-1 GB14048.5 |
Alarm Contacts | SD | Provide an alarm signal when the MCB trip off | IEC60947-2 GB14048.2 |
Shunt Tripper | HDMX | It will let the MCB trip off when the operating voltage exceed the rated voltage by 70%~110% | IEC60947-1 GB14048.1 |
Shunt Tripper + Auxiliary Contact | MX+OF | Remote break the circuit and let the auxiliary contacts control the circuit | IEC60947-1 GB14048.1 |
Over/under Voltage Release | MV+MN | It can peotect the MCB from under / over voltage | IEC60947-2 GB14048.2 |
Technical Data
Working Condition
Temperature: -5℃~+40℃
Altitude : under 2000m
Installation : 35mm DIN rail
Dimensions
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2010
Total Annual:
3000000-3200000
Employee Number:
50~100
Ecer Certification:
Active Member
YUEQING FEEO ELECTRIC CO.,LTD is a professional solar PV electric components manufacturer located in Yueqing City, China. We're specialized in DC circuit breakers, Surge Protective Devices, PV fuses, isolator switches, MC4 connectors etc.With CE, RoHS, CB, TUV certificates and authorized dealers... YUEQING FEEO ELECTRIC CO.,LTD is a professional solar PV electric components manufacturer located in Yueqing City, China. We're specialized in DC circuit breakers, Surge Protective Devices, PV fuses, isolator switches, MC4 connectors etc.With CE, RoHS, CB, TUV certificates and authorized dealers...
Get in touch with us
Leave a Message, we will call you back quickly!