China Weather Proof Zone Control Station , Anti Dust Control Box For Dangerous Area
China Weather Proof Zone Control Station , Anti Dust Control Box For Dangerous Area

  1. China Weather Proof Zone Control Station , Anti Dust Control Box For Dangerous Area

Weather Proof Zone Control Station , Anti Dust Control Box For Dangerous Area

  1. MOQ: 10
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union,Paypal
Supply Ability 5000 pcs per month
Delivery Time 7-15 days
Packaging Details carton,wooden carton
Material Cast Aluminum
Type control station
Application hazardous location
Product Name explosion proof control station
Ex Marking Exe II T6 Gb, Ex tD A21 IP65
Outlets custom
Brand Name Vican
Model Number V-LBZ-18
Certification CNEX,ISO,CE,RoHS
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union,Paypal Supply Ability 5000 pcs per month
Delivery Time 7-15 days Packaging Details carton,wooden carton
Material Cast Aluminum Type control station
Application hazardous location Product Name explosion proof control station
Ex Marking Exe II T6 Gb, Ex tD A21 IP65 Outlets custom
Brand Name Vican Model Number V-LBZ-18
Certification CNEX,ISO,CE,RoHS Place of Origin China
High Light explosion proof push button stationemergency stop control station

 

 

weather proof zone control station and anti-dust control box for dangerous area

 

 

 

Description:

 

  The explosion proof custom control stations can be built to customer specifications with door-mounted pushbuttons, pilot lights, selector switches, or potentiometers. Any combination of devices can be assembled in one of 20 sizes of aluminum enclosures. Custom Push-Button Stations are for applications requiring only operator interface and/or pilot light indication. Stations are available in one-hole to nine-hole arrangements. Operators can be purchased separately. Custom Control Stations Control stations are used to house control components and have the ability to add operators on the cover. The enclosures are available in 20 shapes and sizes that fit any application. Window Enclosures are available with square or rectangular windows. This provides convenient viewing of gauges, meters, or control device displays. Circuit Breakers provide overload and short-circuit protection on feeder or branch circuits, as well as lighting, heating, and motor circuits. The enclosure includes an external breaker operator handle that can be padlocked in on or off position. The circuit breaker can be used as a general service disconnect.

 

Techinical parameters:

 

Rated voltage AC220/380V
Rated current 10A
Using type AC-14, DC-13
Protection grade IP65
corrosion-proof grade WF1
Inlet thread G3/4"
Cable outer dia Φ9mm~Φ14mm
 

 

The dust site is divided into three areas: 20, 21 and 22:

 

Zone 20: Combustible dust continuously or frequently occurs during normal operation in an amount sufficient to form a mixture of flammable dust and air and/or a location and container interior that may form an uncontrollable and extremely thick dust layer.

Zone 21: During normal operation, there may be a place where the amount of dust is sufficient to form a mixture of flammable dust and air but not zoned 20. This area includes locations directly adjacent to the charge or discharge of dust, where dust layers and flammable concentrations of flammable dust and air may be produced under normal operating conditions.

Zone 22: Under abnormal conditions, flammable dust clouds occur occasionally and are only present for a short period of time, or flammable dust occasionally accumulates or may present a dust layer and produce a flammable dust air mixture but not zoned into Zone 21. If it is not guaranteed to exclude flammable dust accumulation or dust layer, it should be divided into 21 zones.

 

Applications:

 

1. Explosive gas mixture hazardous locations: Zone 1 and Zone 2.

2. Explosive gas mixtures: IIA, IIB, IIC.

3, flammable dust environment:20,21,22 area

4, explosion-proof signs: ExdeIIBT6, ExdeIICT6

5.often be used in chemical plant,gas station,oil station,workshop,warehouse, pharmaceuticals,smelting, shipbuilding, military, textile and other flammable and explosive places

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Exporter,Seller

  • Year Established:

    2007

  • Total Annual:

    5 million-10 milion

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

Vican Explosion Proof Technology Co.,ltd, is an explosion-proof electrical high-tech enterprise, strong technical force, advanced technology, and sound quality assurance system, has passed ISO9001, international quality system certification, products designed and manufactured according to nat... Vican Explosion Proof Technology Co.,ltd, is an explosion-proof electrical high-tech enterprise, strong technical force, advanced technology, and sound quality assurance system, has passed ISO9001, international quality system certification, products designed and manufactured according to nat...

+ Read More

Get in touch with us

  • Reach Us
  • Vican Explosion Proof Technology Co.,ltd
  • Room 403, Building 1, No.89 CuiBai Road, Haishu District,Ningbo ,China.
  • https://www.explosionproofpanel.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement