China factories

China factory - Vican Explosion Proof Technology Co.,ltd

Vican Explosion Proof Technology Co.,ltd

  • China,Ningbo ,Zhejiang
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Electrical Explosion Proof Junction Box , Stainless Steel Junction Box With
China Electrical Explosion Proof Junction Box , Stainless Steel Junction Box With

  1. China Electrical Explosion Proof Junction Box , Stainless Steel Junction Box With

Electrical Explosion Proof Junction Box , Stainless Steel Junction Box With

  1. MOQ: 10
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union,Paypal
Supply Ability 5000 pieces per month
Delivery Time 10-15 days
Packaging Details carton
Material Stainless steel
Type junction box
Application hazardous location
Product Name explosion proof junction box
Ex Marking Exe II T6 Gb, Ex tD A21 IP65
Outlets custom
Brand Name Vican
Model Number V-BJX-12
Certification CNEX,ISO,CE,RoHS
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union,Paypal Supply Ability 5000 pieces per month
Delivery Time 10-15 days Packaging Details carton
Material Stainless steel Type junction box
Application hazardous location Product Name explosion proof junction box
Ex Marking Exe II T6 Gb, Ex tD A21 IP65 Outlets custom
Brand Name Vican Model Number V-BJX-12
Certification CNEX,ISO,CE,RoHS Place of Origin China
High Light explosion proof outlet boxhazardous location junction box

 

Electrical explosion proof junction box / flameproof junction box with terminals

 

Description:

Explosion proof junction box with the GB3836 explosion-proof 2000 regulation, flameproof, made its mark is ExdIIB explosion. Applicable to contain type IIA, IIB, the corresponding temperature classes with explosive air mixture of district 1, 2 division places.

Explosion-proof box as flameproof explosion-proof parts, can be used as a control, lighting or power line cable branch connection with, also can be used as tankers power circuit

 

Technical Parameters:

Execution standards GB3836.1, GB3836.2, GB3836.3, GB12476.1, IEC60079
Rated voltage AC 380V/220V/110V/36V/24V
Rated current 20A-200A
Explosion-proof mark ExeII T6 ExtD A21
Protection level IP65
Anti-corrosion grade WF2
Introduction port specification G1/2"~G2.5"

 


Application: 

 

Designed for Explosive atmosphere Zone land Zone 2

Designed for Groups IIA, IIB, IIC

Designed for Combustible dust Zone20, Zone 21, Zone22

Designed for Temperature classesT6

Apply to oil drilling platforms, offshore oil platform, oil derrick, etc for the dangerous sites

Used in electrical control system assendorder and status, monitor

 

 

The gas field is divided into three areas: Zone 0, Zone 1 and Zone 2:

 

Zone 0: A site where explosive mixtures in an explosive atmosphere occur continuously in the form of gases, vapors or mists or exist for long periods of time.

Zone 1: A site where explosive mixtures of gas, vapour or mist may occur in an explosive atmosphere during normal operation. Zone 1 is a typical application site for explosion-proof electrical equipment.

Zone 2: In normal operation, explosive mixtures in the form of gases, vapors or mists are unlikely to occur in explosive atmospheres, and if present, are only occasional and short-lived locations. Usually, "short time" means that the duration is no more than 2 hours.

 

The dust site is divided into three areas: 20, 21 and 22:

 

Zone 20: Combustible dust continuously or frequently occurs during normal operation in an amount sufficient to form a mixture of flammable dust and air and/or a location and container interior that may form an uncontrollable and extremely thick dust layer.

Zone 21: During normal operation, there may be a place where the amount of dust is sufficient to form a mixture of flammable dust and air but not zoned 20. This area includes locations directly adjacent to the charge or discharge of dust, where dust layers and flammable concentrations of flammable dust and air may be produced under normal operating conditions.

Zone 22: Under abnormal conditions, flammable dust clouds occur occasionally and are only present for a short period of time, or flammable dust occasionally accumulates or may present a dust layer and produce a flammable dust air mixture but not zoned into Zone 21. If it is not guaranteed to exclude flammable dust accumulation or dust layer, it should be divided into 21 zones.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Exporter,Seller

  • Year Established:

    2007

  • Total Annual:

    5 million-10 milion

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

Vican Explosion Proof Technology Co.,ltd, is an explosion-proof electrical high-tech enterprise, strong technical force, advanced technology, and sound quality assurance system, has passed ISO9001, international quality system certification, products designed and manufactured according to nat... Vican Explosion Proof Technology Co.,ltd, is an explosion-proof electrical high-tech enterprise, strong technical force, advanced technology, and sound quality assurance system, has passed ISO9001, international quality system certification, products designed and manufactured according to nat...

+ Read More

Get in touch with us

  • Reach Us
  • Vican Explosion Proof Technology Co.,ltd
  • Room 403, Building 1, No.89 CuiBai Road, Haishu District,Ningbo ,China.
  • https://www.explosionproofpanel.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement