Payment Terms | L/C, T/T, Western Union |
Supply Ability | 500 pcs per day |
Delivery Time | 5-20days |
Packaging Details | carton box standard, check the specification |
Material | Copper-free aluminum |
Item type | Explosion- proof lights |
Ip rating | 66 |
Input voltage(v) | AC100-277V/DC12-36V |
Warranty | 5 Years |
Working lifetime(hour) | 50000 |
Brand Name | CODT |
Model Number | EXPLOSION PROTECTION ES02 SERIES EXIT SIGN |
Certification | ATEX, IECEx,ETL,API,ABS |
Place of Origin | CHINA |
View Detail Information
Explore similar products
DC12-48V IP66 Fire Exit Emergency Lighting Explosion Proof
Class I Division 2 LED Exit Emergency Light Explosion Proof
Copper Free Aluminum Explosion Proof Exit Emergency Lights 100-277V
Explosion Proof Exit Sign Light Fixture 100-277V For Hazardous Locations
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 500 pcs per day |
Delivery Time | 5-20days | Packaging Details | carton box standard, check the specification |
Material | Copper-free aluminum | Item type | Explosion- proof lights |
Ip rating | 66 | Input voltage(v) | AC100-277V/DC12-36V |
Warranty | 5 Years | Working lifetime(hour) | 50000 |
Brand Name | CODT | Model Number | EXPLOSION PROTECTION ES02 SERIES EXIT SIGN |
Certification | ATEX, IECEx,ETL,API,ABS | Place of Origin | CHINA |
High Light | IP66 LED Exit Emergency Light ,LED Exit Emergency Light 12V ,36V explosion proof emergency exit lights |
IP66 Emergency Exit Light for Dangerous Place ES02 SERIES EXIT SIGN
ATEX Marking
Ⅱ 2 G Ex db IIB+H T6 Gb 2
Ⅱ 2 D Ex tb IIIC T70°C Db IP66
IP66
IECEx Marking
Ex db IIB+H T6 Gb
Ex tb IIIC T70°C Db
Housing: Die-casting aluminum
Indicator: Tempered glass
Bolts: Stainless steel
Mounting Sling: Stainless steel
Panel: Glass
Label content can be customizable.
Low working wattage for energy saving.
High leakproofness up to IP66.
3/4"NPT or M25 conduit hubs.
Mounting ways: pendant, wall and end bracket mountings.
Hinged-access door.
Optics beam angle can be wide and narrow.
Edge-lit sign.
Can be used outdoors.
Various languages and exit signs are available.
Emergency backup battery for exit sign and spot light for contingency period of 180 minutes.
Two top bright spot lights can be adjusted in horizontal and vertical directions.
Long lifespan up to 50,000 hours.
5-year warranty.
WARNING Risk of fire, electric shock or personal injury. Please turn o ffpower before installation!
READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING. KEEP THIS INSTRUCTIONS FOR FUTURE REFERENCE.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY QUALIFIED ELECTRICIAN WHO IS FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDOUS INVOLVED.
Fixtures must be wired in accordance with the National electrical code and all applicable local codes. Proper grounding is required for safety.
Risk of fire or electric shock. Exit light installation requires knowledge of luminaires and electrical systems. DO NOT open the enclosure when energized. DO NOT try to install if not qualified. Please contact a professional electrician.
Risk of fire or electric shock. Suitable for wet locations. Make sure the power is o ffprior to installation.
Risk of fire or electric shock. Suitable for non-insulated surface and frame.
DO NOT cover fixture with insulation liner or similar material.
DO NOT install in unstable, loose or breakable surfaces.
DO NOT let objects impact or exert force on the surface of the fixture.
EX-ES02C2 and EX-ES02C3: Junction Box or Emergency Backup Box
Type | Model Number | Input |
Junction Box | EX-ES02C2 | Max. AC800V CurrencyCable Cross Section: 2.5mm² 24A Cable Cross Section: 4.0mm² 32A Cable Cross Section: 6.0mm² 41A Cable Cross Section: 10mm² 57A Cable Cross Section: 16mm² 76A Cable Cross Section: 35mm² 125A Cable Cross Section: 70mm² 192A Cable Cross Section: 240mm² 400A |
Battery Box | EX-ES02C3 | |
Junction Box | EX-ES02C2 | |
Battery Box | EX-ES02C3 | |
Type A1: Luminaire
Housing | Model Number | Wattage | Lumens(Im) | Input |
Small Housing | EX-5W ES02AN50 | 5W | 650 | AC100-277V by driver and by IC |
EX-10W ES02AN50 | 10W | 1300 | ||
EX-1*8W ES02AN40 | 8W | 1040 | ||
Big Housing | EX-15W ES02A1N40 | 15W | 1950 | DC12-48V |
EX-20W ES02A1N40 | 20W | 2600 | ||
EX-2*8W ES02A1N40 | 16W | 2080 | ||
EX-3*8W ES02A1N40 | 24W | 3120 |
Type A2: Luminaire + Emergency Backup Battery
Housing | Model Number | Wattage | Lumens(Im) | Input |
Small Housing | EX-5W ES02A2N50 | 5W | 650 | AC100-277V by driver and by IC DC12-48V |
EX-10W ES02A2N50 | 10W | 1300 | ||
EX-1*8W ES02A2N40 | 8W | 1040 | ||
Big Housing | EX-15W ES02A2N40 | 15W | 1950 | |
EX-20W ES02A2N40 | 20W | 2600 | ||
EX-2*8W ES02A2N40 | 16W | 2080 | ||
EX-3*8W ES02A2N40 | 24W | 3120 |
Type B1: Emergency Backup + Luminaire (two pieces of spot light)
Housing | Model Number | Wattage | Lumens(Im) | Input |
Big Housing | EX-XXW ES02B1 | 7W-20W | 910-2600 | AC100-277V by driver and by ICEmergency backup for three hours |
Type B2: Recessed EXIT Signs
Model Number | Wattage | Marks | Input Voltage |
EX-5W ES02B2A | 5W | EXIT | AC100-277V by driver and by IC DC12-48V |
EX-5W ES02B2B | 5W | ← | |
EX-5W ES02B2C | 5W | ↑ | |
EX-5W ES02B2D | 5W | → | |
EX-5W ES02B2E | 5W | ↓ | |
EX-5W ES02B2F | 5W | ↖ | |
EX-5W ES02B2G | 5W | ↙ | |
EX-5W ES02B2H | 5W | → | |
EX-5W ES02B2I | 5W | ↗ | |
EX-5W ES02B2J | 5W | EXIT→ | |
EX-5W ES02B2K | 5W | ← EXIT |
Tpye B3: Pendant EXIT Sign + Emergency Backup Battery
Model Number | Wattage | Marks | Input Voltage |
EX-5W ES02B3A | 5W | EXIT | AC100-277V by driver and by IC DC12-48V |
EX-5W ES02B3B | 5W | ← | |
EX-5W ES02B3C | 5W | ↑ | |
EX-5W ES02B3D | 5W | → | |
EX-5W ES02B3E | 5W | ↓ | |
EX-5W ES02B3F | 5W | ↖ | |
EX-5W ES02B3G | 5W | ↙ | |
EX-5W ES02B3H | 5W | → | |
EX-5W ES02B3I | 5W | ↗ | |
EX-5W ES02B3J | 5W | EXIT→ | |
EX-5W ES02B3K | 5W | ← EXIT |
Type B4: Recessed EXIT Sign + Luminaire (two pieces of spot light) + Emergency Backup Battery
Model Number | Wattage | Marks | Input Voltage |
EX-7W ES02B4A | 7W | EXIT | AC100-277V by driver and by IC DC12-48V |
EX-7W ES02B4B | 7W | ← | |
EX-7W ES02B4C | 7W | ↑ | |
EX-7W ES02B4D | 7W | → | |
EX-7W ES02B4E | 7W | ↓ | |
EX-7W ES02B4F | 7W | ↖ | |
EX-7W ES02B4G | 7W | ↙ | |
EX-7W ES02B4H | 7W | → | |
EX-7W ES02B4I | 7W | ↗ | |
EX-7W ES02B4J | 7W | EXIT→ | |
EX-7W ES02B4K | 7W | ← EXIT |
Type B5: Pendant EXIT Sign + Luminaire (two pieces of spot light) + Emergency Backup Battery
Model Number | Wattage | Head | Exit | Marks | Input Voltage |
EX-XXW ES02B5A | 7W | 7-20W | 1-5W | EXIT | AC 100-277V (by driver or by IC) DC 12-48V |
EX-XXW ES02B5B | 7W | 7-20W | 1-5W | ← | |
EX-XXW ES02B5C | 7W | 7-20W | 1-5W | ↑ | |
EX-XXW ES02B5D | 7W | 7-20W | 1-5W | → | |
EX-XXW ES02B5E | 7W | 7-20W | 1-5W | ↓ | |
EX-XXW ES02B5F | 7W | 7-20W | 1-5W | ↖ | |
EX-XXW ES02B5G | 7W | 7-20W | 1-5W | ↙ | |
EX-XXW ES02B5H | 7W | 7-20W | 1-5W | → | |
EX-XXW ES02B5I | 7W | 7-20W | 1-5W | ↗ | |
EX-XXW ES02B5J | 7W | 7-20W | 1-5W | EXIT→ | |
EX-XXW ES02B5K | 7W | 7-20W | 1-5W | ← EXIT |
XX= Number “7~20”, represent how much wattage.
Type C&D: Emergency Light
Housing | Model Number | Wattage | Emergency Time | Input Voltage |
Model C | EX-3W ES02C | 3W | 180 mins | AC100-277V (by driver and by IC) |
EX-5W ES02C | 5W | 180 mins | ||
EX-10W ES02C | 10W | 180 mins | ||
Model D | EX-3W ES02D | 3W | 180 mins | AC100-277V (by driver and by IC) |
EX-5W ES02D | 5W | 180 mins | ||
EX-10W ES02D | 12W | 180 mins |
Model | Quantity/Carton | Length(cm) | Width(cm) | Height(cm) | Net Weight(kg) | Gross Weight(kg) |
ES02A | 1 PCS | 46 | 27 | 23 | 9.5 | 11.5 |
ES02B01 | 1 PCS | 66 | 51 | 26 | 18 | 21 |
ES02B02 | 1 PCS | 56 | 51 | 26 | 12 | 14.5 |
ES02B03 | 1 PCS | 46 | 51 | 26 | 11 | 13 |
ES02B04 | 1 PCS | 46 | 51 | 26 | 10.5 | 12.5 |
ES02C | 1 PCS | 44 | 43.4 | 28.6 | 9 | 11 |
ES02D | 1 PCS | 44 | 41.5 | 34 | 8.8 | 10.8 |
Wall Mounting with Bracket:
Wall Mounting with Arm:
Type B5
Q1. Can I have a sample order for led light?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2. What about the lead time?
A: 3-5 days for Sample preparing ,8-10 working days for mass production.
Q3. Do you have any MOQ limit for led light order?
A: Low MOQ, 1pc for sample checking is available.
Company Details
Business Type:
Manufacturer
Year Established:
2013
Total Annual:
5000000-1000000
Employee Number:
180~200
Ecer Certification:
Active Member
CODT TECHNOLOGY CO., LIMITED established in 2013. We offer the largest selection of rugged, cutting adage products to suit virtually and industrial application. With so many years of industrial LED lighting experience, we are here to help clients identify a lighting solution that meets your specific... CODT TECHNOLOGY CO., LIMITED established in 2013. We offer the largest selection of rugged, cutting adage products to suit virtually and industrial application. With so many years of industrial LED lighting experience, we are here to help clients identify a lighting solution that meets your specific...
Get in touch with us
Leave a Message, we will call you back quickly!