Payment Terms | T/T |
Delivery Time | 30 days |
Supply Ability | 30 sets/month |
Packaging Details | Plywood Case |
Applied Standard | IEC60695-11-5 |
Control Method | PLC and touch screen |
Burner Diameter | φ0.5±0.1mm |
Flame Height | 12±1mm adjustable |
Gas Source Type | >95% butane gas or propane gas |
Flame Heating Time | From 100°±5°C to 700°±3°C is 23.5S±1s |
Burning Angle | Tilt 45° or vertical |
Burning Time | 0-9999X0.1S |
Brand Name | Sinuo |
Model Number | SN773 |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
UL 1581 VW-1/ FT2 Horizontal And Vertical Flame Test Flammability Test Chamber
UL94 Horizontal And Vertical Flammability Testing Equipment 500W 50W
IEC60695-2-13 Glow Wire Testing Equipment Heat Resistance Test Apparatus
ISO 6941 Electric Vehicle Textile Fabric Flammability Test Equipment
Product Specification
Payment Terms | T/T | Delivery Time | 30 days |
Supply Ability | 30 sets/month | Packaging Details | Plywood Case |
Applied Standard | IEC60695-11-5 | Control Method | PLC and touch screen |
Burner Diameter | φ0.5±0.1mm | Flame Height | 12±1mm adjustable |
Gas Source Type | >95% butane gas or propane gas | Flame Heating Time | From 100°±5°C to 700°±3°C is 23.5S±1s |
Burning Angle | Tilt 45° or vertical | Burning Time | 0-9999X0.1S |
Brand Name | Sinuo | Model Number | SN773 |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | Lighting Flammability Testing Equipment ,IEC60695 Flammability Testing Equipment ,Electric Vehicle needle flame test apparatus |
IEC60695-11-5 Needle Flame Test Equipment
Complied Standards & Clauses
IEC 60695-11-5 “Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance”
Equipment Overview
Samples and Restrictions: Lighting equipment, low-voltage apparatus, household appliance, machine tool electric appliance, electrical machine, electric tool, electronic instrument, electrotechnical instrument, electrical connector, etc., and its parts and components, as well as their insulating materials, engineering plastics or other solid combustible materials.
Application: Simulate the effect of small flames due to fault conditions, use simulation technology to assess fire hazard.
Test Principle: The needle flame tester uses a needle burner with a specified size (Φ0.9mm), passes through a specific gas (butane), and ignites the test sample at a 45° angle. Then the fire hazard of the small flame caused by the fault condition inside the equipment is evaluated according to whether the test product is ignited and the burning duration and burning length.
Structure: Chamber structure, with fume hood.
Power supply: single-phase AC220V±10%, 50/60Hz, or match client's local power supply requirements.
Use Environment: Ambient temperature: 10℃~35℃, relative humidity: 30%~60%, there should be no high concentration dust, no corrosive gas , no flammable and explosive atmosphere around.
Technical Parameters
Model | SN773 | |
Control and Operation Mode | PLC control, operated on 7-inch color touch screen, with infrared remote control | |
Burner Diameter | φ0.5±0.1mm, outer diameter ≤φ0.9mm, length ≥35mm, stainless steel | |
Gas Source Type | >95% butane gas or propane gas (bottled lighter gas can be used) | |
Flame Height | 12±1mm adjustable (with flame height gauge) | |
Flame Heating Time | From 100°±5°C to 700°±3°C is 23.5S±1s | |
Burning Angle | Tilt 45° (when testing) or vertical (when adjusting flame height) | |
Receiving Tray | The 10mm thick pine board is covered with a layer of 12~30g/m³ of silk paper, 200±5mm below the sample | |
Flame Applying Time/ Burning Time | 0-9999X0.1S | |
Temperature Measurement Distance | Distance between burner tip center and test sample: 8±1mm | |
Temperature Calibration | Temperature measuring copper head: Φ4±0.01mm, mass 0.58±0.01g | |
Thermocouple: American original Omega φ0.5 armored nickel-chromium/nickel aluminum wire, K type, temperature resistance 1100° | ||
Temperature measurement distance 6±0.5mm | ||
Air Volume Adjustment | Flame height can be adjusted by adjusting the flow meter | |
Testing Procedure | Automatic control of test program, independent ventilation | |
Lighting | Equipped with a light, with control | |
Test Chamber and Dimensions | >0.5 cubic, black matte background, with exhaust fan, dimensions: 1100*550*1200mm, 130kg |
Company Details
Business Type:
Manufacturer
Year Established:
2019
Employee Number:
<100
Ecer Certification:
Verified Supplier
Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te... Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...
Get in touch with us
Leave a Message, we will call you back quickly!