China New Energy Vehicle Electrical Safety Testing Equipment
China New Energy Vehicle Electrical Safety Testing Equipment

  1. China New Energy Vehicle Electrical Safety Testing Equipment
  2. China New Energy Vehicle Electrical Safety Testing Equipment
  3. China New Energy Vehicle Electrical Safety Testing Equipment
  4. China New Energy Vehicle Electrical Safety Testing Equipment

New Energy Vehicle Electrical Safety Testing Equipment

  1. MOQ: 1
  2. Price: Customized
  3. Get Latest Price
Payment Terms T/T
Delivery Time 45 days
Supply Ability 10 sets/month
Packaging Details Plywood case
Potential Equalization No-load Output <12V
Potential Equalization Test Method Four-wire system
IS Rated Output Load Current 10VA(1000V/10mA) 10mA
IS Output Voltage Setting Range DC:100~1000V continuous adjustable
AC Withstand Voltage Test Type Cold withstand voltage test
AC Withstand Rated Output Load 200VA (AC: 5000V/40mA)
Applied Standard ISO 6469.1
Warranty Term One Year
Brand Name Sinuo
Model Number SNE6808C
Certification Calibration Certificate (Cost Additional)
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Delivery Time 45 days
Supply Ability 10 sets/month Packaging Details Plywood case
Potential Equalization No-load Output <12V Potential Equalization Test Method Four-wire system
IS Rated Output Load Current 10VA(1000V/10mA) 10mA IS Output Voltage Setting Range DC:100~1000V continuous adjustable
AC Withstand Voltage Test Type Cold withstand voltage test AC Withstand Rated Output Load 200VA (AC: 5000V/40mA)
Applied Standard ISO 6469.1 Warranty Term One Year
Brand Name Sinuo Model Number SNE6808C
Certification Calibration Certificate (Cost Additional) Place of Origin China
High Light 200VA Electrical Safety Testing Equipment10mA ev Electrical Safety Testing EquipmentISO6469 New Energy vehicle testing equipment

 

 

ISO 6469 New Energy Electric Vehicle Electrical Safety Testing Equipment

 

Complied Standards & Clauses


ISO 6469-1:2019 Electrically propelled road vehicles — Safety specifications — Part 1: Rechargeable energy storage system (RESS)

 

Equipment Overview


New energy vehicle safety inspection is controlled by the host computer control system, which is composed of vehicle test unit, components test unit, potential equalization test unit, and power battery test unit.

 

Technical Parameters


Potential Equalization
Test method/No-load output voltage Four-wire system
No-load output voltage <12V
Output current setting range DC:1.00~32.00A, continuously adjustable constant current output
Output current resolution 0.01A
Output current accuracy 1.00~9.99A: ± (1% of setting+0.20A)
10.00~32.00A: ± (1% of setting)
Grounding resistance setting range Upper limit: 0~630.0mΩ;
Lower limit: 0~630.0mΩ; 0=off
Grounding resistance measuring range 1.00A≤outpur current≤10.00A, 0.0~600.0mΩ
10.00A≤outpur current≤20.00A, 0.0~300.0mΩ
20.00A≤outpur current≤32.00A, 0.0~200.0mΩ
Grounding resistance measuring resolution 0.1 mΩ/1 mΩ
Grounding voltage measuring range 0~10V
Grounding voltage measuring resolution 0.001V
Resistance to zero 0.0~100.0 mΩ
Grounding voltage measuring accuracy ± (1% of reading+3 mΩ)
Test time setting range 0.0, 0.1~999.9s 0.0=Continuous output
Test time setting resolution 0.1S
Test time setting range accuracy ± (1% of setting+0.05s)
 
Insulation Resistance Test
Rated output load current 10VA(1000V/10mA) 10mA
Output voltage ripple Resistive load, 1000V/1mA, <5%
Output voltage setting range DC:100~1000V continuous adjustable
Output voltage setting resolution 1V
Output voltage setting accuracy ± (1% of setting+3V)
Insulation resistance setting range Upper limit: 0.0001~10GΩ; ∞ = no upper and lower limit judgement
Lower limit: 0.0001~10GΩ;
Insulation resistance measuring range 100~499V: 0.1MΩ~1000 MΩ
500V~1000V: 1.5MΩ~10000 MΩ
Insulation resistance measuring resolution 0.01 MΩ/0.1 MΩ/1 MΩ
Resistance compensation >30MΩ
Insulation resistance measuring range 0.05~99.99~999.9~3000MΩ
Insulation resistance measuring accuracy

100~499V: <100 MΩ: ± (5% of reading+0.5 MΩ)

100 MΩ~1000 MΩ: ± (10% of reading+5 MΩ)

500~1000V:1.5 MΩ~100MΩ:± (2% of reading+0.2 MΩ)

100 MΩ~1999 MΩ: ± (5% of reading+2 MΩ)

2000 MΩ~10000 MΩ: ± (10% of reading+5 MΩ)

  1000 MΩ~3000 MΩ:± (5% of reading+2digitals)
Delay time setting range 0.5~999.9s
Test time setting range 0.0, 0.1~999.9s, 0.0= Continuous output
Test time resolution 0.1S
Test time setting accuracy ± (1% of setting+0.05s)
 
AC Withstand Voltage
Withstand voltage test type Cold withstand voltage test
Rated output load 200VA (AC: 5000V/40mA )
Output voltage adjustment rate <2% (no load to full load)
Output voltage setting range AC:100-5000V ;50Hz/60Hz
Output voltage resolution 1V
Output voltage accuracy ±(1% setting value+3V)
Breakdown current measuring range 0.050~9.999~40.00mA
Breakdown current setting range Upper limit: 0.000-9.999- -40.00mA
Lower limit: 0.000-9.999- -40.00mA 0.000=close
Breakdown current measuring resolution 0.001mA/0.01mA
Zero current 0.000-2.000mA
Breakdown current measurement accuracy ±(1% of reading value + 0.005mA)
Rise time/slow down time 0.0-999.9s
Test time setting range

0.0, 0.1-999.9S

0,0=continuous output

Test time resolution 0.1S
Test time setting accuracy ±(0.1% setting value+0.05s)
Arc detection 1-9 gears (9 is the highest sensitivity)
 
DC Withstand Voltage
Withstand voltage test type Cold withstand voltage test
Output voltage setting range DC:100-6000V
Output voltage resolution 1V
Output voltage accuracy ±(1% setting value+5V)
Breakdown current setting range

Upper limit: 0.000-10.00mA;

Lower limit: 0.000-10.00mA , 0=off

Breakdown current measurement range 0.010-10.00mA
Breakdown current measurement resolution 0.001mA/0.01mA
Zero current 0-2 000mA
Breakdown current measurement accuracy ±(1% of reading value+5 digitals)
Rise time/slow down time 0.0-999.9s
Test time setting range

0.0-999.9S

0.0=continuous output

Test time resolution 0.1S
Test time setting accuracy ±(0.1% setting value+0.05s)
Arc detection 1-9 gears (9 is the highest sensitivity)
 
Leakage Current
Rated load power range Determined by the power of isolation transformer/built-in variable frequency power supply
Leak type setting Single phase: static leakage, dynamic leakage
Output voltage ratio

1.10 times input voltage (output by isolation transformer)/arbitrarily set voltage (output by variable frequency power supply)

 

Output voltage setting range AC:0.0-300.0V
Output voltage setting measuring range AC:5.0-300.0V
Output voltage measurement resolution 0.1V
Output voltage measurement accuracy ±(1.5% of reading value+3V)
Leakage current impedance  
Leakage current setting range

Upper limit: 0.000-5.000mA;

Lower limit: 0.000-5.000mA

0.000=off

Leakage current measurement range The current test range is 0.050-5.000mA
Leakage current measurement resolution 0.001mA
Zero current 0.000-2.000mA
Leakage current measurement accuracy ± (1.5% of reading value + 0.005mA)
Test time setting range

0.0, 0.5-999.9S

0.0=continuous output

Test time resolution 0.1S
Test time setting accuracy ± (0.1% setting value+0.05s)
 
Slow Charge Function (Optional)
Output voltage setting range AC:0.0-300.0V
Output voltage measurement range AC: 5.0~300.0V
Output voltage resolution 0.1V
Output voltage measurement accuracy ±(0.25% of reading value+0.25% of measuring range)
Charging current setting range

6.000-63.00A (that is, the upper limit of current)

Note: The lower limit of current cannot be set, it is fixed to 0

Measuring current setting range Upper and lower limits: 0.000-9.999-75.00A
Current measuring range 0.050~9.999~75.00A
Current measuring resolution 0.001A/0.01A
Current measuring accuracy ±(0.25% of reading value+0.25% of measuring range)
Power factor measuring range 0.100~1.000
Power factor measuring resolution 0.001
Power factor upper limit setting range 0.000~1.000
Power factor lower limit setting range 0.000~1.000
Power factor measuring accuracy ±(0.5% of reading value+0.01)
Delay time 0.2~999.9S
Test time setting range

0.0, 0.1-999.9S

0.0=continuous output

Test time resolution 0.1S
Test time accuracy ±(0.1% of setting value+0.05s)
 
Low voltage slow charge test (Optional)
Rated load power range Determined by the power of isolation transformer/built-in variable frequency power supply
Output voltage ratio

0.85 times input voltage (output by isolation transformer)/arbitrarily set voltage (output by variable frequency power supply)

 

Output voltage setting range AC:0.0-300.0V
Output voltage measurement range AC: 5.0~300.0V
Output voltage resolution 0.1V
Output voltage measurement accuracy ±(0.25% of reading value+0.25% of measuring range)
Charging current setting range

6.000-63.00A (that is, the upper limit of current)

Note: The lower limit of current cannot be set, it is fixed to 0

Delay time 0.2~999.9S
Test time setting range

0.0, 0.1-999.9S

0.0=continuous output

Test time resolution 0.1S
Test time accuracy ±(0.1% of setting value+0.05s)
 
Fast Charge Function (Optional)
Comprehensive measurement of charging output voltage DC:200.0-500.0V
Comprehensive measurement of charging output current ≤50A
Charge resolution 0.01KW.h
SOC 0~100%
Plug temperature setting range 0~100°C
Plug temperature resolution 1°C
Battery temperature measurement range 0~150°C
Test time setting range

0.0, 0.1-999.9min

0.0=continuous output

Test time resolution 0.1min
Test time accuracy ±(0.1% of setting value+0.05min)
 
Battery Pack /Whole Vehicle Insulation Test
Insulation resistance setting range

Upper limit 0.00-100.0MΩ 0=close,

lower limit 0.00- 100 00MΩ

Insulation resistance measurement range 0.20- 100.00MΩ
Insulation resistance measurement resolution 0.01 MΩ
Insulation resistance measurement accuracy ±(5% reading value + 0.03% of measuring range)
Test time setting range 4.0~999.9S
Test time resolution 0.1S
Test time setting accuracy ±(0.1% setting value+0.05s)
 
 

Questions & Answers


Q: What is for vehicle test unit:

A: It contains:

1. Fast charging port: DC withstand voltage, insulation resistance, DC grounding (potential equalization), fast charging function, whole vehicle insulation resistance, insulation test verification

2. Slow charging port: AC withstand voltage, insulation resistance, AC grounding, leakage current, slow charging function

 

Q: What is for components testing unit:

A: AC withstand voltage, insulation resistance.

 

A:What is for potential equalization unit:

Q:It contains:

1. The resistance between the negative grounding point of the battery and the PEU shell

2. The resistance between the negative ground point of the battery and the housing of the drive motor

3. The resistance between the battery negative ground point and the charger shell

4. The resistance between the negative ground point of the battery and the PTC

5. The resistance between the negative grounding point of the battery and the air-conditioning compressor housing

6. The resistance between the battery negative grounding point and the steering motor housing

7. The resistance between the negative ground point of the battery and the air pump casing

8. The resistance between the battery negative ground point and the fastening screw of the battery cover

 

 

A: What is for power battery PEESS unit:
Q: It contains:

By measuring the voltage value, the standard resistance is known, and the battery pack insulation is calculated according to the GT/18384.1-2015 formula.

The known standard tester for testing is built in the test system, and the test wiring changes during the whole test process are inside the test system, and the automatic switching is completed without manual wiring changes.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2019

  • Employee Number:

    <100

  • Ecer Certification:

    Verified Supplier

    Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...     Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...

+ Read More

Get in touch with us

  • Reach Us
  • Sinuo Testing Equipment Co. , Limited
  • Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China
  • https://www.evtestequipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement