Payment Terms | T/T |
Supply Ability | 15 Sets / Month |
Delivery Time | 15 days |
Packaging Details | Plywood Case |
Applied Standard | IEC 62196-1Ed.4CDV 2020 |
Applied Clauses | Clause 14.1.5, 14.1.6 |
Operation Method | Manual Operation |
Weight Configuration | 165-750N |
Test Plugs | Customized |
Test Station | Single station |
Applied Figures | Fig13, fig14 |
Applied Table | Table 5 |
Brand Name | Sinuo |
Model Number | SN1013 |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
IEC62196 Electric Vehicle Connector Plug Drive Over Test Equipment 5000N
IEC62196 EV Connector Testing Equipment Plugs Temperature Rise Test System
EV Glow Wire Test Apparatus PLC Control IEC 62196 Glow Wire Test Equipment
IEC 62196 Electric Vehicle Air Saturated Test Chamber 304 Stainless Steel
Product Specification
Payment Terms | T/T | Supply Ability | 15 Sets / Month |
Delivery Time | 15 days | Packaging Details | Plywood Case |
Applied Standard | IEC 62196-1Ed.4CDV 2020 | Applied Clauses | Clause 14.1.5, 14.1.6 |
Operation Method | Manual Operation | Weight Configuration | 165-750N |
Test Plugs | Customized | Test Station | Single station |
Applied Figures | Fig13, fig14 | Applied Table | Table 5 |
Brand Name | Sinuo | Model Number | SN1013 |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | Socket Interlock Withdraw Force Test Apparatus ,EV Switch Socket Force Test Apparatus |
IEC62196 EV Switch Socket Interlock Withdraw Force Test Apparatus
Complied Standards & Clauses for Switch Socket Interlock Withdraw Force Test Apparatus
IEC 62196-1:2020 clause 14.1.5, 14.1.6, fig13, fig14.
IEC 62196-1:2014 clause 17.2.
Equipment Overview for Switch Socket Interlock Withdraw Force Test Apparatus
Test purpose: The structure of the charging interface should allow the charging gun to be easily inserted and pulled out, and should prevent the charging gun from falling out of the socket during normal use. Verify that the maximum force required to pull the charging cable out of the appliance socket is within the range specified in the standard.
Test Principle: Maximum pull-out force of the socket: Apply the maximum pull-out force specified in the standard (the total force of the main weight, additional weight, hook (clamping device), and test plug) to the test plug, and the plug should come out of the socket.
Structure: This device is composed of the clamping device installed under the top plate A, the main weight F, the additional weight G and the test plug C. The device frame is compatible with GB/T20234.1 Figure 5 and GB11918.4 Figure 102, including mechanical load test of horizontal horizontal charging interface, locking device test and insertion force test.
Note: The adjustable clamp is adopted, which can be switched vertically and horizontally, and can clamp various products; the D clamp is replaced by a ring, which is more convenient to operate and use; the main weight is directly counterweighted without a bracket.
Technical Parameters for Switch Socket Interlock Withdraw Force Test Apparatus
A Maximum withdrawal force
The maximum withdrawal force of the socket-outlet shall meet the requirements of Table 1.
Apply the maximum withdrawal force specified in the standard (total force of the principal weight, supplementary weight, hook (clamping device) to the test plug, when the supplementary weight is dropped from a height of 50mm, the plug should come out of the socket.
User should select an appropriate weight for the test according to the following table:
Sample type (AC A) | Withdrawal N | Principal weight N | Supplementary weight N |
6-40 | 165 | 148.5 | 16.5 |
41-80 | 300 | 270 | 30 |
81-150 | 440 | 396 | 44 |
151-250 | 660 | 396+148.5+49.5 | 66 |
Sample type (DC A) | |||
Any | 750 | 396+148.5+49.5+15 | 75 |
Clause 17.2 A | |||
<59 | 150 | 135 | 15 |
60-99 | 275 | 247.5 | 27.5 |
100-125 | 400 | 270+90 | 40 |
Note: The principal weight already contains the test plug and hook weight |
B Minimum withdrawal force
Insert the gauge with the minimum withdrawal force specified in the standard (that is, the test pin (single pin) that meets the requirements of this standard, the total mass of the pin should be equal to the value specified in the table) into each individual socket in the socket-outlet. The gauge must not be removed from the socket within 30 seconds.
Nominal pin diameter mm | Diameter of gauge mm +0 -0.01 | Minimum total force N |
5 | 4.80 | 2.5 |
6 | 5.80 | 5 |
7 | 6.80 | 5 |
8 | 7.80 | 10 |
10 | 9.80 | 15 |
12 | 11.80 | 20 |
Note: The minimum withdrawal force already includes the weight of the gauge |
C Structure features
This device is mainly composed of the installation fixture, the clamping device, principal weight, supplementary weight and the test plug. Based on experience, the pull clamp is changed to a counterweight, the weight hook is directly connected to the test plug, and the fixture for holding the sample is configured. The specific shape is shown in figure 1.
D Test plug
The test plug, according to the relevant standard sheets, shall have finely ground contacts of hardened steel, having a surface roughness not exceeding 0,8 µm over their active length and spaced at the nominal distances, with a tolerance of ±0,05 mm.
The dimension of the plug contacts or the distance between contact surfaces for other types of plug contacts shall be in accordance with the minimum dimension(s) given in the relevant standard sheets, with a tolerance of +0,010mm
The test plugs are not included in this test apparatus, please use those test plugs that client already ordered separately as following:
No.: | Standard | Figure No.: | Name | QTY |
1 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-I sheet 1 | Test-plug1:32A,250 V AC VEHICLE INLET | 1 |
2 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-Ilb sheet 1 | Test-plug1:63 A, 480 V THREE-PHASE OR 70 A, 250 V SINGLE PHASE | 1 |
3 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-Ild sheet 1 | Test-VEHICLE INLET2: 63 A, 480 V THREE-PHASE OR 70 A, 250 V SINGLE PHASE | 1 |
4 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-Ilf sheet 1 | Test-VEHICLE INLET3: 63 A, 480 V THREE-PHASE OR 70 A, 250 V SINGLE PHASE | 1 |
5 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-Illa sheet 1 | Test-Plug 4: 16 A, 250 V SINGLE-PHASE PLUG WITH 1 PILOT CONTACT | 1 |
6 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-Illb sheet 1 | Test-Plug 6: 32 A, 250 V SINGLE-PHASE PLUG WITH 2 PILOT CONTACTS | 1 |
7 | IEC62196-2/Ed.3/CDV © IEC(E) | STANDARD SHEET 2-Illc sheet 1 | Test-Plug 8: 63 A, 480 V THREE-PHASE PLUG WITH 2 PILOT CONTACTS | 1 |
8 | IEC62196-3/Ed.2/CDV © IEC(E) | STANDARD SHEET 3-Ib Sheet 1 | Test VEHICLE CONNECTOR 10 | 1 |
9 | IEC62196-3/Ed.2/CDV © IEC(E) | STANDARD SHEETS CONFIGURATION BB VEHICLE COUPLER 250 A 900 V DC STANDARD SHEET 3-Iia Sheet 1 | Test VEHICLE CONNECTOR 11 | 1 |
10 | IEC62196-3/Ed.2/CDV © IEC(E) | STANDARD SHEET 3-IIIa Sheet 2 | Test VEHICLE INLET 12 | 1 |
11 | IEC62196-3/Ed.2/CDV © IEC(E) | STANDARD SHEET 3-Iva VEHICLE INLETMODES 2, 3 AND 4 Sheet 2 | Test VEHICLE INLET 13 | 1 |
12 | IEC62196-3/Ed.2/CDV © IEC(E) | STANDARD SHEET 3-Ivb VEHICLE INLET ALL MODES Sheet 1 | Test VEHICLE INLET 14 | 1 |
E Test pins
The test pins are not included in this test apparatus, please use those test pins that client already ordered separately as following:
Nominal pin diameter mm | Diameter of gauge mm +0 -0.01 | Minimum total force N |
5 | 4.80 | 2.5 |
6 | 5.80 | 5 |
7 | 6.80 | 5 |
8 | 7.80 | 10 |
10 | 9.80 | 15 |
12 | 11.80 | 20 |
Note: The minimum withdrawal force already includes the weight of the gauge |
Configuration and Details for Switch Socket Interlock Withdraw Force Test Apparatus
Gauge configuration:
Made of S136, the pin is the minimum value of the standard size, the tolerance is +0.01 0 mm, the spacing is ±0.05mm, and the finish is 0.8um
16A maximum pull-out force matching socket gauge*1;
32A maximum pull-out force matching socket gauge*1;
DC maximum pull-out force matching socket gauge*1;
Weight configuration:
165: 148.5N main weight x1+16.5N additional weight x1;
300N: 270N main weight x1+30N additional weight x1;
440N: 396N main weight x1+44N additional weight x1;
660N: 594N main weight x1+66N additional weight x1;
750N: 675N main weight x1+75N additional weight x1;
Note: The weight of the main weight includes the weight of the hook, and the weight of the weight is realized by superposition and combination.
Test content:
7.11.8: Charging interface mechanical load test
7.15.1.1: Locking device test
7.17: Insertion force test (extraction force part)
Test hold time: 60s, the jack drives the tray up and down to lift the weight to achieve
Number of tests: 4 times, once in each 90° direction around the horizontal axis, manually
Test load:
AC charging gun: 100N
DC charging gun: 140N
1.0 kg
Test reference figure:
Company Details
Business Type:
Manufacturer
Year Established:
2019
Employee Number:
<100
Ecer Certification:
Verified Supplier
Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te... Sinuo Testing Equipment Co., Limited established in 2019, but Sinuo has rich experience in manufacturing test euipment, test system and offering overall laboratory construction of electronic and electrical products. Sinuo's main products include electrical vehicle te...
Get in touch with us
Leave a Message, we will call you back quickly!