Packaging Details | By standard export box/carton |
Delivery Time | Around 7 working days upon receipt of payment |
Payment Terms | 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead |
Supply Ability | 2000 sets/month |
Un Available | 5v / 12v / 24v / 48v / 60v / 110v |
Uc Option | 6V / 14V / 26V / 55V / 65V / 170V |
Iimp | 2.5kA(per line) |
In(8/20) | 10kA (per line) |
Nominal current | 0.5A / 1A |
Dimension | 12x64.5x92mm |
Data Custom-Made | Available |
HS Code For Surge Protection | 8536300000 |
Model Number | TS-SP Series |
Certification | CE Compliance |
Place of Origin | Guangdong,China |
Brand Name | TSTLP |
View Detail Information
Explore similar products
Three Phase / 3 Pole Surge Protection Device 385Vac 60kA - 120kA Class 1
30kA Surge Protection Device For Home 220v / 230v / 320v / 380v / 440v
Hazardous Area Surge Protection Equipment For 4-20mA Measuring Control And Bus
Industrial Bus Control Industrial Surge Protector , RS422 / RS485 Voltage Surge
Product Specification
Packaging Details | By standard export box/carton | Delivery Time | Around 7 working days upon receipt of payment |
Payment Terms | 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead | Supply Ability | 2000 sets/month |
Un Available | 5v / 12v / 24v / 48v / 60v / 110v | Uc Option | 6V / 14V / 26V / 55V / 65V / 170V |
Iimp | 2.5kA(per line) | In(8/20) | 10kA (per line) |
Nominal current | 0.5A / 1A | Dimension | 12x64.5x92mm |
Data Custom-Made | Available | HS Code For Surge Protection | 8536300000 |
Model Number | TS-SP Series | Certification | CE Compliance |
Place of Origin | Guangdong,China | Brand Name | TSTLP |
High Light | 3 phase surge protector ,electrical surge protection devices |
Data Signal Surge Protector / 0~20mA & 4-20mA Surge Protection Device Types , 5v - 110v available
Relative Data Line Surge Protectors
TS-SP series Data Line Surge Protectors,which follows IEC 61643-21; GB 18802.21; YD/T 1542. are installed at LPZ 0A -2 or higher, or directly at the upstream near the protected devices Providing the protection for 2 single wires of unbalanced interfaces for measuring and controlling system.. Mainly used in lightning protection for measuring and controlling system. such as the field bus, input/output interface of the 0-20mA surge protection, 4-20mA control line. (TS-SP110 could also be used for telephone line,ADSL/ISDN line surge protection)
Model | TS-SP5 | TS-SP12 | TS-SP24 | TS-SP48 | TS-SP60 | TS-SP110 | |
Nominal voltage | Un | 5V | 12V | 24V | 48V | 60V | 110V |
Rated voltage (max. continuous voltage) | Uc | 6V-/ 4.2V~ | 14V-/ 10V~ | 26V-/ 19V~ | 55V-/ 39V~ | 65V- / 50V~ | 170V-/ 130V~ |
Nominal current | IL | 0.5A | 0.5A | 0.5A | 0.5A | 0.5A | 1A |
Lightning discharge current (10/350) | Iimp | 2.5kA (per line), 5kA (total) | |||||
Nominal discharge current (8/20) | In | 10kA (per line 20kA (total) | |||||
Voltage protection level at Iimp | Up | ≤30V (line-line) ≤17V (line-PG) | ≤60V(line-line) ≤30V(line-PG) | ≤90V(line-line) ≤45V(line-PG) | ≤150V (line-line) ≤75V (line-PG) | ≤200V (line-line) ≤100V (line-PG) | ≤600V (line-line) ≤300V (line-PG) |
Response time | tA | ≤1ns(line-line) ≤1ns(line-PG) | 25ns(line-line) 25ns(line-PG) | ||||
Bandwidth | fG | 1.6MHz (AD-PG) | 2.9MHz (AD-PG) | 5.1MHz (AD-PG) | 8.5MHz (AD-PG) | 10.8MHz (AD-PG) | 24.0MHz (AD-PG) |
Series impedance per line | R | 1.4 Ω | 1.9 Ω | 2.2 Ω | 2.2 Ω | 2.2 Ω | 0.4 Ω |
Capacitance | C | 3nF (line-line) 5nF (line-PG) | 1nF (line-line) 2nF (line-PG) | 0.7nF(line-line) 1.3nF(line-PG) | 0.3nF(line-line) 0.6nF (line-PG) | 0.3nF (line-line) 0.6nF (line-PG) | 0.2nF(line-line) 1.4nF (line-PG) |
Operating temperature range | -40°C...+80°C | ||||||
Relative humidity | ≤95% (25°C) | ||||||
Cross-sectional area | Max. 2.5mm2 flexible | ||||||
Mounting on | 35mm DIN rail | ||||||
Enclosure material | Yellow thermoplastic, UL94-V0 | ||||||
Standards | IEC 61643-21; GB 18802.21; YD/T 1542 | ||||||
Compliance | CE (LVD, EMC) |
Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the data surge protection device.
PDF Catalog Download - TS-SP Series SPD.pdf
PDF Catalog Download - TS-SC Series SPD.pdf
PDF Catalog Download - TS-SD5-SD24 SPD.pdf
PDF Catalog Download - TS-ITS-ME SERIES SPD.pdf
Tag: data surge protection devices, 20mA surge protection, surge protection device types
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2013
Total Annual:
5,000,000-6,000,000
Employee Number:
150~200
Ecer Certification:
Active Member
TSTLP ~ BRING YOU SAFER FUTURE NO LIGHTNING ACCIDENT IS ALLOWED Your Suitable ISO 9001:2015 Q.M.S. Certified Lightning Protection Manufacturer for Medium-High-End World Market. ONE company that focuses on HIGH-Quality Lightning Protection Produc... TSTLP ~ BRING YOU SAFER FUTURE NO LIGHTNING ACCIDENT IS ALLOWED Your Suitable ISO 9001:2015 Q.M.S. Certified Lightning Protection Manufacturer for Medium-High-End World Market. ONE company that focuses on HIGH-Quality Lightning Protection Produc...
Get in touch with us
Leave a Message, we will call you back quickly!