China factories

China factory - TS Lightning Protection Co.,Limited

TS Lightning Protection Co.,Limited

  • China,Heyuan ,Guangdong
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China ESE Active Lightning Conductor For House Protection NF C 17 - 102 Compliant
China ESE Active Lightning Conductor For House Protection NF C 17 - 102 Compliant

  1. China ESE Active Lightning Conductor For House Protection NF C 17 - 102 Compliant
  2. China ESE Active Lightning Conductor For House Protection NF C 17 - 102 Compliant
  3. China ESE Active Lightning Conductor For House Protection NF C 17 - 102 Compliant

ESE Active Lightning Conductor For House Protection NF C 17 - 102 Compliant

  1. MOQ: Negotiable
  2. Price: Negotiable if good quantity
  3. Get Latest Price
Packaging Details 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton
Delivery Time Around 7 working days upon receipt of payment
Payment Terms 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead
Supply Ability 1000 pcs/month
Classification Active Lightning Conductor
Efficiency 30 microsec
Material Stainless Steel
lightning current withstanding Iimp ≥ 200kA
Standards NF C 17-102 & UNE21.186
Weight(g) 3,000
Brand Name TSTLP
Model Number SMT-ESE30/LSC3
Certification CE approval / Patent
Place of Origin Guangdong, P.R.C.

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton Delivery Time Around 7 working days upon receipt of payment
Payment Terms 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead Supply Ability 1000 pcs/month
Classification Active Lightning Conductor Efficiency 30 microsec
Material Stainless Steel lightning current withstanding Iimp ≥ 200kA
Standards NF C 17-102 & UNE21.186 Weight(g) 3,000
Brand Name TSTLP Model Number SMT-ESE30/LSC3
Certification CE approval / Patent Place of Origin Guangdong, P.R.C.
High Light early streamer emission lightning conductorlightning conductor for house

Active lightning conductor for house lightning protection NFC17-102 compliant

 

  • What's Active Lightning Conductor ?

lightning conductor generating a streamer earlier than a simple rod lightning conductor when compared in the same
conditions
NOTE – An active lightning conductor is made up of a striking point, an emission device, a fixing element and a
connection to the down conductors.

 

  • Technical Data

 

  • SMT-ESE30 Active Lightning Conductor OPERATING PRINCIPLES
Detection of download leader Continuous measuring of electric field gradient (ΔE/Δt)
Upward streamer development conditions ESE Technology optimizing the streamer development conditions
Upward streamer emission Sparking by High Voltage Impulses
Internal circuits 3 Independent working unit
Central rod Full electrical continuity
Metal housing Superior Stainless Steel
On-site testing capabilities Proprietary Active Lightning Conductor tester
Maintenance Free (thanks to TSTLP advanced technology & superior material)
Warranty 10 years

 

SMT-ESE30 Active Lightning Conductor MECHANICAL SPECIFICATIONS
Fixing on SS/GI pole M20 Thread as international
Down conductor connection Specific clamp
PACKING
Dimensions 23*23*45 cm box/pc, 4pc in 49*50*50cm carton
Packing Contents TSTLP® E.S.E. active lightning conductor Head, Nut, Hex key;
Approx Gross Weight 4,000 g
Environmental sustainability Totally recyclable

 

  • RADIUS PROTECTION - Ese Lightning Conductor

The protection radius of TSTLP ese lightning conductor is related to its height (h) relative to the surface to be protected, to its efficiency and to the selected protection level

for h ≥ 5 m;

and

Rp = h × Rp(5)/5 for 2 m ≤ h ≤ 5 m

Rp (h) (m): is the protection radius at a given height h

h (m) : is the height of the active lightning conductor tip over the horizontal plane through the furthest point of the object to be protected

r (m) : 20 m for protection level I

30m for protection level II

45m for protection level III

60m for protection level IV

Δ (m) Δ = ΔT x 106

Field experience has proved that Δ is equal to the efficiency obtained during the active lightning conductor evaluation tests

 

  • Radius Protection Table of SMT-ESE30 Active lightning conductor

 

  • TSTLP Active lightning conductor Protection of A Building

Installation procedures for TSTLP Active Lightning Conductor is governed by NF C 17-102 (UNE 21.186) and follows a series of simple rules catering for all types of structure

 

 

  1. ESE Active Lightning Conductor
  2. Elevation pole
  3. Copper conductor
  4. Copper clamp
  5. Lightning counter
  6. Test clamp
  7. Earth clamp
  8. Protection sheath
  9. Inspection housing
  10. Copper earthing
  11. Rod to conductor clamp
  12. Earth rod
  • TSTLP Active lightning conductor for house, high-volatge lines... protection

 

PDF Datasheet Download - TSTLP SMT-ESE30.pdf

 

Tag: active lightning conductor, lightning conductor for house

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2013

  • Total Annual:

    5,000,000-6,000,000

  • Employee Number:

    150~200

  • Ecer Certification:

    Active Member

       TSTLP ~ BRING YOU SAFER FUTURE NO LIGHTNING ACCIDENT IS ALLOWED Your Suitable ISO 9001:2015 Q.M.S. Certified Lightning Protection Manufacturer for Medium-High-End World Market. ONE company that focuses on HIGH-Quality Lightning Protection Produc...        TSTLP ~ BRING YOU SAFER FUTURE NO LIGHTNING ACCIDENT IS ALLOWED Your Suitable ISO 9001:2015 Q.M.S. Certified Lightning Protection Manufacturer for Medium-High-End World Market. ONE company that focuses on HIGH-Quality Lightning Protection Produc...

+ Read More

Get in touch with us

  • Reach Us
  • TS Lightning Protection Co.,Limited
  • Hongdiyuan Industrial Park, Wufeng Avenue, Linjiang Town, Jiangdong New District, Heyuan, Guangdong, P.R.C.
  • https://www.ese-lightningrod.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement