China factories

China factory - Shanghai Korain Biotech Co., Ltd

Shanghai Korain Biotech Co., Ltd

  • China,Shanghai ,Shanghai
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China High Sensitive Canine ELISA Kits Immunosorbent Assay Kit For Accurate Quantitati
China High Sensitive Canine ELISA Kits Immunosorbent Assay Kit For Accurate Quantitati

  1. China High Sensitive Canine ELISA Kits Immunosorbent Assay Kit For Accurate Quantitati

High Sensitive Canine ELISA Kits Immunosorbent Assay Kit For Accurate Quantitati

  1. MOQ: Negotiation
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability Western Union, T/T
Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package
In Stock Yes
Known as SP
Discount Available
Assay Time 2 hours
Lead Time Within 48 hours
Customized Acceptable
Brand Name BT Lab
Model Number Cat.No E0288Ca
Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability Western Union, T/T Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package In Stock Yes
Known as SP Discount Available
Assay Time 2 hours Lead Time Within 48 hours
Customized Acceptable Brand Name BT Lab
Model Number Cat.No E0288Ca Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China
High Light sandwich elisa kitenzyme linked immunosorbent assay elisa

High Sensitive Canine SP Sandwich Immunosorbent Assay Kit For Accurate Quantitative Detection

 

Cat.No E0288Ca

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Dont add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-SP antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells ( Not blank control well ). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

 

Standard Curve Range: 0.2ng/ml - 70ng/ml

Sensitivity: 0.13ng/ml

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Specimen

Collection Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

 

Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

 

Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

 

Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

Tissue and other body fluids Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

Note

  • Sample concentrations should be predicted before being used in the assay. If the sample concentration is not within the range of the standard curve, users must contact us to determine the optimal sample for their particular experiments.
  • Samples to be used within 5 days should be stored at 2-8°C. Samples should be aliquoted or must be stored at -20°C within 1 month or -80°C within 6 months. Avoid repeated freeze thaw cycles.
  • Samples should be brought to room temperature before starting the assay.
  • Centrifuge to collect sample before use.
  • Samples containing NaN3 can’t be tested as it inhibits the activity of Horse Radish Peroxidase (HRP).
  • Collect the supernatants carefully. When sediments occurred during storage, centrifugation should be performed again.
  • Hemolysis can greatly impact the validity of test results. Take care to minimize hemolysis.

*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample matrix interference may falsely depress the specificity and accuracy of the assay.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2010

  • Ecer Certification:

    Active Member

Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc... Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Korain Biotech Co., Ltd
  • #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
  • https://www.elisatest-kit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement