China Chitinase-3-Like Protein 1 Sandwich Human ELISA Kit 2 Hours Assay Length
China Chitinase-3-Like Protein 1 Sandwich Human ELISA Kit 2 Hours Assay Length

  1. China Chitinase-3-Like Protein 1 Sandwich Human ELISA Kit 2 Hours Assay Length

Chitinase-3-Like Protein 1 Sandwich Human ELISA Kit 2 Hours Assay Length

  1. MOQ: Negotiation
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability Western Union, T/T
Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package
Lead Time Within 48 hours
In Stock Yes
OEM Acceptable
Assay Principle Sandwich
Sample Serum,plasma,urine,tissue,cell culture supernatant
Storage 2-8°C
Brand Name BT Lab
Model Number Cat.No E2063Hu
Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability Western Union, T/T Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package Lead Time Within 48 hours
In Stock Yes OEM Acceptable
Assay Principle Sandwich Sample Serum,plasma,urine,tissue,cell culture supernatant
Storage 2-8°C Brand Name BT Lab
Model Number Cat.No E2063Hu Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China
High Light enzyme immunoassay kitenzyme assay kits

Human High Specificity and Sensitivity Chitinase-3-like Protein 1 ELISA Assay Kit 2 Hours Assay Length

 

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

CV(%) = SD/mean x 100

Intra-Assay: CV<8%

Inter-Assay: CV<10%

 

Intended Use

This sandwich kit is for the accurate quantitative detection of human Chitinase-3-like Protein 1 (also known as YKL-40/CHI3L1) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

 

Cat.No E2063Hu

Standard Curve Range: 1ng/ml - 400ng/ml

Sensitivity: 0.61ng/ml

Size: 96 wells

 

Reagent Provided

Components Quantity
Standard Solution (480ng/ml) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (25x) 20ml x1
Biotinylated human YKL-40/CHI3L1 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

 

 

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (480ng/ml) with 120μl of standard diluent to generate a 240ng/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (240ng/ml) 1:2 with standard diluent to produce 120ng/ml, 60ng/ml, 30ng/ml and 15ng/ml solutions. Standard diluent serves as the zero standard(0 ng/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:

 

240ng/ml Standard No.5 120μl Original Standard + 120μl Standard Diluent
120ng/ml Standard No.4 120μl Standard No.5 + 120μl Standard Diluent
60ng/ml Standard No.3 120μl Standard No.4 + 120μl Standard Diluent
30ng/ml Standard No.2 120μl Standard No.3 + 120μl Standard Diluent
15ng/ml Standard No.1 120μl Standard No.2 + 120μl Standard Diluent

 

Standard Concentration Standard No.5 Standard No.4 Standard No.3 Standard No.2 Standard No.1
480ng/ml 240ng/ml 120ng/ml 60ng/ml 30ng/ml 15ng/ml

 

 Wash Buffer Dilute 20ml of Wash Buffer Concentrate 25x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2010

  • Ecer Certification:

    Active Member

Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc... Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Korain Biotech Co., Ltd
  • #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
  • https://www.elisatest-kit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement