China factories

China factory - Shanghai Korain Biotech Co., Ltd

Shanghai Korain Biotech Co., Ltd

  • China,Shanghai ,Shanghai
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Strong Specificity Human F5 Sandwich Enzyme Assay Kits 96 Wells Customized
China Strong Specificity Human F5 Sandwich Enzyme Assay Kits 96 Wells Customized

  1. China Strong Specificity Human F5 Sandwich Enzyme Assay Kits 96 Wells Customized

Strong Specificity Human F5 Sandwich Enzyme Assay Kits 96 Wells Customized

  1. MOQ: Negotiation
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability Western Union, T/T
Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package
Known as F5
Lead Time Within 48 hours
Target Protein Coagulation Factor 5
Uniprot No. P12259
Assay Length 2 hours
Custom Available
Brand Name BT Lab
Model Number Cat.No E4114Hu
Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability Western Union, T/T Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package Known as F5
Lead Time Within 48 hours Target Protein Coagulation Factor 5
Uniprot No. P12259 Assay Length 2 hours
Custom Available Brand Name BT Lab
Model Number Cat.No E4114Hu Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China
High Light enzyme immunoassay kitenzyme assay kits

Strong Specificity Human F5 Sandwich ELISA Kit Customized Coagulation Factor 5 ELISA Test Kit

 

Cat.No E4114Hu

Standard Curve Range: 1ng/ml - 400ng/ml

Sensitivity: 0.53ng/ml

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

 

Assay Principle

This ELISA Test Kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Human F5 antibody. F5 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Human F5 Antibody is added and binds to F5 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated F5 antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Human F5. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

 

Reagent Provided

Components Quantity
Standard Solution (480ng/ml) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (25x) 20ml x1
Biotinylated Human F5 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

 

Material Required But Not Supplied

  • 37°C±0.5°C incubator
  • Absorbent paper
  • Precision pipettes and disposable pipette tips
  • Clean tubes
  • Deionized or distilled water
  • Microplate reader with 450 ± 10nm wavelength filter

 

Precautions

  • Prior to use, the ELISA Test Kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The ELISA Test Kit should not be used beyond the expiration date.

 

Specimen Collection

Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

 

Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

 

Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

 

Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

Tissue Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

 

Note

  • Sample concentrations should be predicted before being used in the assay. If the sample concentration is not within the range of the standard curve, users must contact us to determine the optimal sample for their particular experiments.
  • Samples to be used within 5 days should be stored at 2-8°C. Samples should be aliquoted or must be stored at -20°C within 1 month or -80°C within 6 months. Avoid repeated freeze thaw cycles.
  • Samples should be brought to room temperature before starting the assay.
  • Centrifuge to collect sample before use.
  • Samples containing NaN3 can’t be tested as it inhibits the activity of Horse Radish Peroxidase (HRP).
  • Collect the supernatants carefully. When sediments occurred during storage, centrifugation should be performed again.
  • Hemolysis can greatly impact the validity of test results. Take care to minimize hemolysis.

*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample matrix interference may falsely depress the specificity and accuracy of the assay.

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2010

  • Ecer Certification:

    Active Member

Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc... Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Korain Biotech Co., Ltd
  • #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
  • https://www.elisatest-kit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement