Payment Terms | L/C, T/T, Western Union |
Supply Ability | 300 set per month |
Delivery Time | 5-8 work days |
Packaging Details | Carton Packing |
Display | OLED display |
Communication | Optional Modbus communication function |
Closed loop control | The voltage / current feedback / power feedback |
Load type | Resistance and inductive load |
Control mode | Phase control mode and the zero position control |
Input signal | Five input signal types |
Brand Name | Noker |
Model Number | PS16E |
Certification | ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
Thyristor Electronic Solid State Relay Three Phase With True RMS Value Display
Overcurrent Protection Thyristor Power Module Three Phase Wide Current Range
Lightweight Thyristor Diode Module Single Phase 50 / 60Hz Power Frequency
5-200A Voltage Regulation Module / Soft Starter Thyristor Photoelectric
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 300 set per month |
Delivery Time | 5-8 work days | Packaging Details | Carton Packing |
Display | OLED display | Communication | Optional Modbus communication function |
Closed loop control | The voltage / current feedback / power feedback | Load type | Resistance and inductive load |
Control mode | Phase control mode and the zero position control | Input signal | Five input signal types |
Brand Name | Noker | Model Number | PS16E |
Certification | ISO9001 | Place of Origin | China |
High Light | voltage regulator module ,bridge rectifier module |
PS16E Series Up To 2000Amp OLED Display Closed Loop Resistance And Inductive Load Single Phase Thyristor Power Regulator
PS16E Series Up To 2000Amp OLED Display Closed Loop Resistance And Inductive Load Single Phase Thyristor Power Regulator is widely used in resistance and inductive Load heating control.
Features
1. Lightweight, compact mounted three phase thyristor regulator
2. The standard OLED digital setter can read and set the internal function parameters of the regulator (voltage, current, power, load impedance and each function parameter)
3. The phase control mode and the zero position control mode can be switched by the setter (in which the zero position control mode is divided into variable period zero crossing trigger and fixed period zero crossing trigger)
4. The new zero-crossing trigger with fixed period can control the inductive load and the primary side of transformer.
5.The voltage / current feedback / power feedback type can be selected (specify one) when the phase control mode is adopted.
6. Can add Modbus communication function, can be a variety of set values and voltage and current power and other parameters read to the upper computer
7. Selection of five input signal types (contact signal DC4--20mA, DC1--5V, DC 0--5V, DC 0--10V)
8. Rated current: 30A 50A 80A 100A 200A 250A 300A 400A 500A 1000A 1500A 2000A
9. Rated voltage: AC220V / AC380V
Specification
Phase number | Single phase |
Control mode | Phase control mode (phase shift trigger) |
Zero position control mode (variable period zero crossing trigger) | |
Feedback | No feedback, voltage feedback, current feedback, power feedback (when a feedback mode is specified for phase control) |
Rated voltage | AC 220V/ AC 380V |
Allowable voltage change | ±10% of Rated voltage |
Rated frequency | 50/60Hz |
Allowable frequency change | Rated frequency ±1Hz |
Rated current | 30A,50A,80A,100A,150A,200A,250A,300A,400A,500A,600A,800A,1000A,1500A,2000A |
Input Signal | DC 4--20mA input impedance: 120Ω |
DC 1--5V input impedance: 10k Ω | |
DC 0-- 5V input impedance: 10k Ω | |
DC 0--10V input impedance: 10k Ω | |
Output Range | No feedback, 0-- 98% output range of rated voltage |
Voltage feedback, 0-- 98% output range of rated voltage | |
Current feedback, 0-- 100% output range of rated voltage | |
Power feedback, 0-- 98% output range of rated voltage*0-- 100% output range of rated current | |
Output Precision | No feedback, rated voltage±10% |
Voltage feedback, rated voltage±3% | |
Current feedback, rated voltage±3% | |
Power feedback, rated power±3% | |
Load Type | Resistive load (phase shift trigger, Variable period zero crossing trigger) |
Inductive load (phase shift trigger) | |
Minimum load current | 0.5A above (98% output of rated voltage) |
Other function | Soft start, soft off(0--60S),Operation stop switch, external setters (slope, base point, manual, etc.) overcurrent protection, overvoltage protection, current limit, voltage limit |
Alarm action | 1. Overcurrent alarm: ALM alarm light, alarm parameters display, alarm contact output |
2. Overvoltage alarm: ALM alarm light, alarm parameters display, alarm contact output | |
3. Load breakage alarm Alm alarm lamp on, alarm parameters display, alarm contact output | |
4. Radiator overtemperature alarm: Alm alarm light on, alarm parameter display, alarm contact output | |
Alarm output number | One point |
Alarm contact capacity | AC250V 3A |
Cooling mode | Rated current 30A (including 30A) below self-cooling |
Rated current 50 A (including 50 A) above air cooling | |
Output setting range | Slope setting (internal), 0~100% of output range |
Operating ambient temperature | -10℃--55℃ |
Operating environment humidity | 30%RH--90%RH |
Insulation impedance | DC 500V,20MΩ |
Insulation strength | AC 2000V/min |
Materials and Coatings | Plate / spray coating |
Communication
Communication protocol | Modbus RTU(optional) |
Communication interface | RS485 |
Baud rate | 4800bps 9600bps 19200bps |
Setting unit
Setting item | 1. Run (run / stop) output mode (automatic / manual) |
2. Control mode (phase control / zero control) | |
3. Feedback type (no feedback / voltage feedback / current feedback / power feedback) | |
4. Manual output value (0 / 100%) slope setting (0 / 100%) | |
5. Current limit value (0 ~ 100% rated current) voltage limit value (0 ~ 100% rated voltage) | |
6. Over-current protection (on / off) overcurrent protection value (1.2 times rated current) | |
7. Over-voltage protection (on / off) overvoltage protection value (1.2 times rated voltage) | |
8. Soft start time (0 ~ 60s) soft turn-off time (0 ~ 60s) | |
9. Load off alarm (on / off) | |
10. Communication address, communication rate, communication parity check, host computer control (on / off) | |
11. Fixed period zero crossing control feedback (on / off) | |
Display item | Voltage value, current value, power value, load impedance value, input signal percentage, alarm code, various set values, various states |
Digital Display | OLED display (display resolution 128 × 64) measurement value, set value, alarm value, etc. |
Status Display | 4 LED status lights (red, green) running state, manual state, stop state, alarm state |
Shipment and Packaging
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2002
Total Annual:
3000000-8000000
Employee Number:
100~200
Ecer Certification:
Active Member
Noker Electric is an automation & drive focused global company, providing global customers with control, display, drive and system solutions & other related products and services, under the support of its excellent electrical and electronic technology as well as strong control technical forc... Noker Electric is an automation & drive focused global company, providing global customers with control, display, drive and system solutions & other related products and services, under the support of its excellent electrical and electronic technology as well as strong control technical forc...
Get in touch with us
Leave a Message, we will call you back quickly!