China factories

China factory - Delta Technology (Chongqing) Co., Ltd.

Delta Technology (Chongqing) Co., Ltd.

  • China,Chongqing ,Chongqing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Oltc High Quality Electrical Testing on Load Tap Changer Tester
China Oltc High Quality Electrical Testing on Load Tap Changer Tester

  1. China Oltc High Quality Electrical Testing on Load Tap Changer Tester
  2. China Oltc High Quality Electrical Testing on Load Tap Changer Tester
  3. China Oltc High Quality Electrical Testing on Load Tap Changer Tester
  4. China Oltc High Quality Electrical Testing on Load Tap Changer Tester
  5. China Oltc High Quality Electrical Testing on Load Tap Changer Tester
  6. China Oltc High Quality Electrical Testing on Load Tap Changer Tester

Oltc High Quality Electrical Testing on Load Tap Changer Tester

  1. MOQ: 1 set
  2. Price: USD1.0
  3. Get Latest Price
Payment Terms Western Union, T/T, L/C
Supply Ability 100 sets each month
Delivery Time 10 days
Packaging Details OLTC is packed in veneer case
Item Name Oltc High Quality Electrical Testing on Load Tap Changer Tester
Functions Automatic Transformer on Load Tap Changer Tester
Features Transformer on Load Tap Changer Tester
Current Source Charge 3A/1A, 0.6A/0.2A
Power Supply AC 220V, 50Hz/60Hz
Temperature -10-40°C
Humidity <85%RH
Application Field Electrical Industry, Oil Laboratory, etc.
Delivery Lead Time 7 Days After The Order Is Confirmed
Shipping Method Suggest to Ship by Air or Express
Protection Functions Power-off Protection, Over-Voltage Protection
Max. Voltage of The Port 24V
Max. Range of Transition Resistance 100ohm
Measuring Range 1A: 0.4-20ohm, 0.2A: 10-100ohm
Record Time of Waveform 300ms
Sample Rate 30K
OEM Service Yes, available, for free
Brand Name Delta
Model Number OLTC
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, T/T, L/C Supply Ability 100 sets each month
Delivery Time 10 days Packaging Details OLTC is packed in veneer case
Item Name Oltc High Quality Electrical Testing on Load Tap Changer Tester Functions Automatic Transformer on Load Tap Changer Tester
Features Transformer on Load Tap Changer Tester Current Source Charge 3A/1A, 0.6A/0.2A
Power Supply AC 220V, 50Hz/60Hz Temperature -10-40°C
Humidity <85%RH Application Field Electrical Industry, Oil Laboratory, etc.
Delivery Lead Time 7 Days After The Order Is Confirmed Shipping Method Suggest to Ship by Air or Express
Protection Functions Power-off Protection, Over-Voltage Protection Max. Voltage of The Port 24V
Max. Range of Transition Resistance 100ohm Measuring Range 1A: 0.4-20ohm, 0.2A: 10-100ohm
Record Time of Waveform 300ms Sample Rate 30K
OEM Service Yes, available, for free Brand Name Delta
Model Number OLTC Certification ISO9001
Place of Origin China

Oltc High-Quality Electrical Testing on Load Tap Changer Tester

Introduction:

  • Oltc High-Quality Electrical Testing on Load Tap Changer Tester can record switch operation waveform in the overall process. The longest time is 6.4s.

  • Oltc High-Quality Electrical Testing on Load Tap Changer Tester can test various parameters such as transition waveform, transition time, transition resistance, and three-phase synchronization one time and analyze results automatically.

  • Oltc High-Quality Electrical Testing on Load Tap Changer Tester has power-off protection, over-voltage protection, perpetual clock, and high-speed printing.

Features:

  • Test transformers of type Y0 Y Δ and display resistance value directly.
  • Automatically analyze waveform faults and mark the fault.
  • Automatically adjust resistance value and time range according to sampling data.
  • Transformer type Δ is able to display to synchronization status of three phases.
  • Be able to test with winding or without winding.
  • Four terminal connection modes provide high accuracy of resistance measurement.
  • Continuous test to save time of power off.
  • Make a word report.
  • 800×480 colorized LCD with touch screen and high-speed printer.
  • Store 1000 groups of data and also can be saved by USB flash disk.

 

Parameters:

Item Name Oltc High-Quality Electrical Testing on Load Tap Changer Tester
Three-phase constant current source charge Three-phase constant current source charge
Maximum voltage of the port 24V
Maximum range of transition resistance 100Ω
Measuring range 1A: 0.4Ω~20Ω                            0.2A: 10Ω~100Ω
Record time of waveform 300ms
Sample rate 30k
Resolution of time 0.1ms
Resolution of resistance 0.1Ω
Accuracy of transition resistance ±5% Reading±0.1Ω
Accuracy of transient time ±0.5% Reading±0.2mS
Temperature -10-40°C
Humidity <85%RH

 

 

Oltc High-Quality Electrical Testing on Load Tap Changer Tester ​Real Picture:

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Year Established:

    2012

  • Total Annual:

    10000000-100000000

  • Employee Number:

    100~300

  • Ecer Certification:

    Verified Supplier

Delta Technology (Chongqing) Co., Ltd. is a high-tech enterprise focusing on R&D, production, and sales of Electric Testing Equipment and Fire Resistance Testing Equipment. Safety is important to the electrical, construction, and transportation industries, thus, Delta Technology aims t... Delta Technology (Chongqing) Co., Ltd. is a high-tech enterprise focusing on R&D, production, and sales of Electric Testing Equipment and Fire Resistance Testing Equipment. Safety is important to the electrical, construction, and transportation industries, thus, Delta Technology aims t...

+ Read More

Get in touch with us

  • Reach Us
  • Delta Technology (Chongqing) Co., Ltd.
  • No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010
  • https://www.electrictest-equipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement