China IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka
China IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka

  1. China IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka
  2. China IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka
  3. China IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka
  4. China IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka

IP40 Indoor Mini Circuit Breaker 10KA SB6H 4P 3p 40a 10ka

  1. MOQ: 100PCS
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/P, T/T
Supply Ability 100000pcs per Month
Delivery Time 15days or Depends on ordering QTYS
Breaking capacity 4.5KA
Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P
Application Household
Standard IEC/EN60898-1, IEC/EN 60947-2
Rated Current 10A,20A,40A,63A
Terminal connection type Cable, Busbar
Color White enclosure, Green handle
Type Miniature circuit breaker
Brand Name YOKG
Model Number SB6H
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/P, T/T Supply Ability 100000pcs per Month
Delivery Time 15days or Depends on ordering QTYS Breaking capacity 4.5KA
Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P Application Household
Standard IEC/EN60898-1, IEC/EN 60947-2 Rated Current 10A,20A,40A,63A
Terminal connection type Cable, Busbar Color White enclosure, Green handle
Type Miniature circuit breaker Brand Name YOKG
Model Number SB6H Certification CE
Place of Origin China
High Light IP40 Indoor Mini Circuit Breaker4P Mini Circuit Breaker 10KAIP40 MCB 3p 40a 10ka

Indoor IP40 Mini Circuit Breaker SB6H 3P,4P 10KA MCB

 

Instantaneous tripping characteristic:

Circuit breaker SB6 are designed for protection of distribution and branch circuits, having different load;

♦ Curve B----Device should not work in 0.1 second at current 3 In; at current 5 In should work in less than 0.1S

♦ Curve C---- Device should not work in 0.1 second at current 5 In; at current 10 In should work in less than 0.1S

♦ Curve D---- Device should not work in 0.1 second at current 10 In; at current 20 In should work in less than 0.1S

 

Specifications:

Poles 1P,1P+N, 2P, 3P, 3P+N, 4P
Electrical specification
Rated current(A) In 1-63
Rated frequency(Hz) 50/60
Rated working voltage(V) Ue 1P:230/400~, 2/3/4P: 400~
Rated insulated voltage(V) Ui 500
Impulse withstand voltage(KV) Uimp 6
Rated short-circuit breaking capacity(KA) Icn

 

4.5

Instantaneous tripping type B,C,D
Maximum working voltage Umax 440
Minimum working voltage Umin 12
Dielectric test voltage (kv) 2
Service life Mechanical standard value 10000
(O-C) Electrical Standard value 4000
Control and indication:
Shunt release (SHT) Optional
Undervoltage release(UVT) Optional
Auxiliary contact(AUX) Optional
Alarm contact(ALT) Optional
Contact position indicator Default
Fault indication None
Connection and installation:
Ambient temperature (with daily average≤35℃) -5℃~+40℃
Protection degree All sides IP40
Connection terminal IP20
Wire(㎟) 16
Busbar(㎟) 16
Mounting Cable/Busbar
Pollution degree 2
Reference temperature for setting of thermal element(℃) 30
Storage temperature(℃) -25℃~+70℃
Tightening torque 3.0
Connection Top and Bottom
Dimensions(mm) a(1P/2P/3P/4P) 17.5/35/52.5/70
b(1P/2P/3P/4P) 83/83/83/83
(WxHxL) c(1P/2P/3P/4P) 67/67/67/67

 

Application:

 

The Indoor Mini Circuit Breaker Can be used for: Short-circuit protection, Isolation function, Overload protection, Indication function of contact position, 35mm Din-rail installation, top incoming and bottom outgoing wiring type, or bottom incoming and top outgoing wiring type, able to select electrical accessories and achieve distant indication of MCB condition; breaking, closed, and fault tripping and select electrical accessories and realize under-voltage and over-voltage protection of MCB and distant shunt release

 

 

 Over-current operating characteristics:

No. Rated current of release (A) Initial state Test current Specified time Result to be obtained Remarks
1 1~63 code state 1.13 In t ≤ 1h Non-trip  
2 1~63 upon the previous test 1.45 In t < 1h trip setting current up to specified value steadily in 5s
3 In ≤ 32 code state 2.55 In 1s <t <60s trip  
In > 32 code state 2.55 In 1s <t <120s trip  
4 1~63 code state 3 In t ≤0.1s Non-trip B type
1~63 code state 5 In t <0.1s trip B type
1~63 code state 5 In t ≤0.1s Non-trip C type
1~63 code state 10 In t <0.1s trip C type
1~63 code state 10 In t ≤0.1s Non-trip D type
1~63 code state 20 In t <0.1s trip D type

 

 

The Number of Poles:

 

Dimensions:

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    1999

  • Total Annual:

    7.5 Million -8 Million

  • Employee Number:

    50~70

  • Ecer Certification:

    Verified Supplier

    We, Yueqing Zeyi electrical Co., Ltd. is intended on creating a professional contactor manufacturing enterprise. Adhere to this business concept, have been focusing on the contactor industry for nearly 20 years, concentrate on the design and manufacture of CJX2 (WC1) series products. N...     We, Yueqing Zeyi electrical Co., Ltd. is intended on creating a professional contactor manufacturing enterprise. Adhere to this business concept, have been focusing on the contactor industry for nearly 20 years, concentrate on the design and manufacture of CJX2 (WC1) series products. N...

+ Read More

Get in touch with us

  • Reach Us
  • YueQing ZEYI Electrical Co., Ltd.
  • Sifang Industrial Park, Beibaixiang Town, YueQing Wenzhou Zhejiang Province China
  • https://www.electric-contactor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement