Payment Terms | L/C, D/P, T/T |
Supply Ability | 100000pcs per Month |
Delivery Time | 15days or Depends on ordering QTYS |
Packaging Details | Standard export packing or According to customer's demand |
Type | Residual Current |
Number of poles | 2P,4P |
Rated current | 16-100A |
Working type | AC, AC+S, A, A+S |
Rated working voltage | 2P:230VAC, 4P: 400VAC |
Place of origin | Wenzhou, China |
Brand Name | YOKG |
Model Number | PR8NM |
Certification | CE, KEMA |
Place of Origin | China |
View Detail Information
Explore similar products
RCCB ELCB Residual Current Circuit Breaker ID 2P Red Copper 4P 25A 40A 63A
Earth Leakage Circuit Breaker 10A 16A 20A 25A B Type 4P RCCB 32A 40A 63A
Earth Leakage Residual Current Circuit Breaker ID 2P 4P 25A 40A 63A RCCB
ID Series Magnetic RCCB Leakage Protector 2 Pole 30ma 10A 16A 20A 25A 32A 40A
Product Specification
Payment Terms | L/C, D/P, T/T | Supply Ability | 100000pcs per Month |
Delivery Time | 15days or Depends on ordering QTYS | Packaging Details | Standard export packing or According to customer's demand |
Type | Residual Current | Number of poles | 2P,4P |
Rated current | 16-100A | Working type | AC, AC+S, A, A+S |
Rated working voltage | 2P:230VAC, 4P: 400VAC | Place of origin | Wenzhou, China |
Brand Name | YOKG | Model Number | PR8NM |
Certification | CE, KEMA | Place of Origin | China |
High Light | PR8NM Leakage Protector ,Leakage Protector 4 pole 400V ,400V Residual Current Operated Circuit Breaker |
Leakage Protector PR8NM Residual Current Operated Circuit Breaker 2pole
Product Description:
16-100 A rated current 2 pole and 4 pole Leakage Protector are widely used in housing, tertiary sector and industry, 35mm din-rail installation is supproted. It is mainly used for controling electric circuits, it can be used for protecting people from indirect or direct contacts. Keep you away from fire hazard which caused by insulation faults during installation.
Specifications:
Poles | 2P,4P |
Electrical Specification | |
Rated current (A) In | 16-100A |
Rated working voltage (V) Ue | 2P:230, 4P:400 |
Rated insulated voltage (V) Ui | 500 |
Impulse withstand voltage (kV) Uimp | 6 |
Rated short circuit breaking capacity (kA) Inc/I△n | 6 |
Rated residual current (mA) I△n | 10,30,100,300 |
Rated residual making and breaking capacity (A) I△m | 1000 |
residual current working type | AC,AC+S, A, A+S |
residual current protection type | Electromagnetic |
Dielectric test voltage(kV) | 2.5 |
Service life Mechanical Standard value | 4000 |
(O-C) Electrical Standard value | 2000 |
Control And indication | |
Shunt release (SHT) | NONE |
Undervoltage release (UVT) | NONE |
Auxiliary contact(AUX) | NONE |
Contact position indicator | NONE |
Fault indication | DEFAULT |
Connection And Installation | |
Ambient temperature (with daily average ≤35℃) | -5℃ ~ +40℃ |
Protection degree All sides | IP40 |
connection terminal | IP20 |
Wire(m㎡) | 35 |
Busbar (m㎡) | 35 |
Mounting | Cable/Busbar |
Reference temperature for setting of thermal element | 30 |
Pollution degree | 2 |
Storage temperature(℃) | -25℃ ~ +70℃ |
Connection | Top |
Dimensions(mm) a(2P/4P) | 36/72 |
b(2P/4P) | 84/84 |
c(2P/4P) | 79.5/79.5 |
Selection:
♦ Detectable wave form
♦ AC type
♦ A type
RCCB for which tripping ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowing rising, Symbol
Tripping sensitivity:
♦ 30 mA--additional protection against direct contact
♦ 100mA--co-ordinated with the earth system according to the formula In<50/R, to provide protection against indirect contacts
♦ 300mA, protection against indirect contacts, as well we fire hazard
Tripping time:
♦ Instantaneous: It ensures instantaneous tripping (without time-delay)
♦ Short time delay : It ensures any tripping at least 10ms
♦ Selective : It ensures total discrimination with a nonselective RCD placed downstream
Connection Diagram:
The diagram of distribution line:
Package and delivery:
Certificates:
FAQ:
1. Could I have prices of your products?
Well welcome. Please feel free to send us any inquiry. You will get our reply in 24 hours.
2. Can we print our logo/website/company name on products?
Yes, OEM and ODM are available.
3. What's the lead time for regular order?
7-15 days for order quantity less than 2000pcs. For more quantity, we can negotiate about it.
4. Do you inspect the finished products?
Our products 100% self-inspection and testing before packing.
5. How about payment terms?
30% deposit, the rest payment balance against B/L copy.
Company Details
Business Type:
Manufacturer
Year Established:
1999
Total Annual:
7.5 Million -8 Million
Employee Number:
50~70
Ecer Certification:
Verified Supplier
We, Yueqing Zeyi electrical Co., Ltd. is intended on creating a professional contactor manufacturing enterprise. Adhere to this business concept, have been focusing on the contactor industry for nearly 20 years, concentrate on the design and manufacture of CJX2 (WC1) series products. N... We, Yueqing Zeyi electrical Co., Ltd. is intended on creating a professional contactor manufacturing enterprise. Adhere to this business concept, have been focusing on the contactor industry for nearly 20 years, concentrate on the design and manufacture of CJX2 (WC1) series products. N...