Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Payment Terms | L/C, T/T |
Supply Ability | 15,000pcs per month |
Delivery Time | 10 working days after received your payment |
Packaging Details | Carton |
Product Name | horizontal concealed fan coil unit |
Installation | Ceiling |
Cooling Capacity(kW) | 2.15-13.7 |
Heating Capacity(kW) | 3.58-22.16 |
Air Flow(m3/h) | 279-1952 |
Aluminum Fins | Shutter-type hyperbolic and hydrophilic fins |
Test Pressure (Mpa) | 3.3 |
Brand Name | EuroKlimat |
Model Number | EKCW-A |
Certification | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
Vertical Single phase Exposed Chilled Water Fan Coil Unit Floor Standing
Floor Standing / Ceiling Exposed Chilled Water Fan Coil Unit
High Efficiency DC Brushless Horizontal Concealed Fan Coil Unit
Package Chilled Water Horizontal Exposed Fan Coil Unit Ceiling installation
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 15,000pcs per month |
Delivery Time | 10 working days after received your payment | Packaging Details | Carton |
Product Name | horizontal concealed fan coil unit | Installation | Ceiling |
Cooling Capacity(kW) | 2.15-13.7 | Heating Capacity(kW) | 3.58-22.16 |
Air Flow(m3/h) | 279-1952 | Aluminum Fins | Shutter-type hyperbolic and hydrophilic fins |
Test Pressure (Mpa) | 3.3 | Brand Name | EuroKlimat |
Model Number | EKCW-A | Certification | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Place of Origin | China | ||
High Light | chilled water fan coil unit ,commercial fan coil units |
Dual pipe 4 rows large temperature horizontal concealed fan coil unit ESP 50 pa
Specifications
Model Performance |
EKCW 200AA |
EKCW 300AA |
EKCW 400AA |
EKCW 500AA |
EKCW 600AA |
EKCW 800AA |
EKCW 1000AA |
EKCW 1200AA |
EKCW 1400AA |
||
Rated air flow (m3/h; under static pressure of 12 Pa, 30 Pa, and 50 Pa) |
H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
M | 279 | 418 | 558 | 697 | 836 | 1115 | 1394 | 1673 | 1952 | ||
L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | 1190 | ||
Rated cooling capacity (W) | Total heating/cooling capacity | H | 2125 | 3385 | 4390 | 4902 | 6207 | 8096 | 10165 | 11066 | 13744 |
Sensible heating/cooling capacity | H | 1233 | 2059 | 2848 | 3353 | 4179 | 5572 | 7125 | 7961 | 9770 | |
Rated heating capacity (W) | H | 3576 | 5427 | 6915 | 8335 | 12238 | 13216 | 16587 | 18339 | 22160 | |
Rated input power (W) | Static pressure of 12 Pa | H | 32 | 46 | 56 | 73 | 93 | 133 | 164 | 188 | 229 |
Static pressure of 30 Pa | H | 41 | 53 | 72 | 86 | 107 | 142 | 183 | 217 | 239 | |
Static pressure of 50 Pa | H | 46 | 65 | 77 | 90 | 115 | 162 | 187 | 227 | 279 | |
Working current (A) | Static pressure of 12 Pa | H | 0.15 | 0.21 | 0.26 | 0.33 | 0.42 | 0.61 | 0.74 | 0.85 | 1.04 |
Static pressure of 30 Pa | H | 0.20 | 0.24 | 0.33 | 0.39 | 0.48 | 0.65 | 0.83 | 0.99 | 1.09 | |
Static pressure of 50 Pa | H | 0.21 | 0.29 | 0.35 | 0.41 | 0.52 | 0.74 | 0.85 | 1.03 | 1.27 | |
Sound dB(A) | Static pressure of 12 Pa | H | 33.5 | 32.5 | 38.5 | 41.5 | 44.5 | 45.0 | 48.0 | 49.0 | 51.0 |
Static pressure of 30 Pa | H | 39.5 | 40.0 | 43.0 | 44.0 | 46.0 | 46.0 | 50.5 | 50.5 | 51.5 | |
Static pressure of 50 Pa | H | 42.0 | 43.0 | 45.0 | 46.0 | 47.5 | 48.5 | 50.5 | 52.5 | 53.0 | |
Water flow (m3/h) | 0.21 | 0.33 | 0.43 | 0.48 | 0.60 | 0.79 | 0.99 | 1.07 | 1.32 | ||
Water resistance (cooling) (kPa) | 5 | 13 | 22 | 10 | 16 | 16 | 25 | 20 | 29 | ||
Water resistance (heating) (kPa) | 4 | 9 | 18 | 8 | 13 | 13 | 20 | 17 | 24 | ||
Coil | Type | Mechanically expanded quality copper tubes specially designed for air conditioners with shutter-type hyperbolic aluminum fins | |||||||||
Working pressure | 1.6MPa | ||||||||||
Test pressure | Airtightness test under pressurized water: 3.3 MPa | ||||||||||
Fan | Type | Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates | |||||||||
Qty. | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Motor | Type | Single-phase ball-bearing capacitive motor with a high precision and low operation sound | |||||||||
Qty. | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | ||
Power supply | 220V~/50Hz | ||||||||||
Protection grade | IP20 | ||||||||||
Insulation grade | B | ||||||||||
Inlet/outlet water pipe | Pipe diameter | Rc3/4 taper pipe with internal thread | |||||||||
Condensate water pipe | Pipe diameter | Diameter R 3/4 taper pipe with external threads | |||||||||
Net weight (no electric heater) | No return air plenum | kg | 11.8 | 14.3 | 16.8 | 17.9 | 19.1 | 28.4 | 31.4 | 34.3 | 41.3 |
With return air plenum | kg | 14.8 | 17.9 | 20.8 | 22.2 | 23.7 | 34.4 | 37.8 | 41.5 | 49.5 | |
Electric heater (optional) |
Power supply | 220V~/50Hz | 380V/3N~/50Hz | ||||||||
Electric heating capacity | kW | 1.0/2.0 | 1.0/2.0/3.0 | 2.0/3.0/4.0 | 2.0/3.0/4.0 | 2.0/3.0/4.0 | 3.0/4.0/5.0 | 3.0/4.0/5.0 | 4.0/5.0/6.0 | 5.0/6.0/7.0 | |
Net weight (with electric heater) | No return air plenum | kg | 14.9 | 17.5 | 20.5 | 21.8 | 23.2 | 33.4 | 36.6 | 40.1 | 47.8 |
With return air plenum | kg | 17.9 | 21.1 | 24.5 | 26.1 | 27.8 | 39.4 | 43.0 | 47.3 | 56.0 |
Note:
■ Working conditions for cooling: inlet air temperature - dry/wet bulb 27°C/19.5°C; temperature of inlet/outlet water - 5°C/15°C.
■ Working conditions for heating: inlet air temperature - dry bulb 21°C; inlet water temperature 60°C; water flow - equal to that for cooling
operation.
■ Rated air flow is measured under standard atmosphere using dry coils (dry bulb 20°C).
■ Sound pressure grade and sound level are measured in a semi-silent room as per GB/T 19232-2003.
■ H, M and L represent high, medium and low fan speed respectively.
■ Static pressure refers to outlet static pressure.
■ All performance parameters in the above table are measure with a power supply of 220V~/50Hz.
■ The right/left orientation of connection pipes are exchangeable on site (cooling/heating capacity needs to be multiplied by a correction factor
of 0.93 after exchange).
1.Compact Exterior
With a compact, graceful and robust design, this
super-thin unit can be concealed in a small space
inside the ceiling.
2.Low Noise
The unit features a forward-pitched low-speed centrifugal fan with wide impellers. The fan has a good
dynamic balance and a stable performance, and minimizes the operation sound while ensuring enough air
flow and the static pressure of outlet air by using efficient sound-dampening and heat-insulation material.
3.Efficient and Energy Saving
To maximize heat transfer and exchange efficiency, the unit features heat exchange coils made of quality
copper tubes, efficient hyperbolic aluminum shutter fins, precise mechanic tube expansion and a fan with
wide impellers and a high air supply capacity.
4.Easy and Flexible Installation
The unit features a symmetric design and can be easily installed. The left and right connection pipes are
exchangeable. For units with a return air plenum, the air return mode can be customized.
5.Safe and Leakage-proof
The condensate water collector are molded as a whole (no welding line or dots) and entirely coated with
fireproof material to prevent leakage. A specially designed pitch on the collector also helps ensure smooth
discharge of condensate water.
6.Easy Maintenance
The unit features a single-phase capacitive motor with a low operation sound and a long service life thanks
to a quality precision ball bear that is hermetic, fully lubricated, rustproof and durable. All wires leading out of
the motor are protected against damage using flexible metal tubes.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Seller,Other
Year Established:
1963
Total Annual:
>150 milion
Employee Number:
>1000
Ecer Certification:
Active Member
EUROKLIMAT (EK) was established in 1963 in Italy. For the past half a century, it has become famous as an energy-saving air-conditioning manufacturer in Italy and globally. Continuous innovation, new product development and top manufacturing quality are the driving... EUROKLIMAT (EK) was established in 1963 in Italy. For the past half a century, it has become famous as an energy-saving air-conditioning manufacturer in Italy and globally. Continuous innovation, new product development and top manufacturing quality are the driving...
Get in touch with us
Leave a Message, we will call you back quickly!