Product Name | Total Heat Recovery Unit Modular Air-Cooled Heat Pump |
Cooling Capacity(kW) | 58 |
Heating Capacity(kW) | 63 |
Max outgoing water temp.( °C) | 55 |
Refrigerant | R22 |
Circuit water pump | Optional |
Heat recovery capacity KW | 70.5 |
Brand Name | EuroKlimat |
Model Number | EKAC |
Certification | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
High Efficiency R22 Heat Recovery Unit Air Conditioning Chiller For Hotels /
Household R410A Total Heat Recovery Air Cooled Heat Pump Unit With 65 C Hot
Energy Saving Scroll Heat Recovery Unit 8 Ton Air Conditioner Heat Pump
Commercial Heat Recovery Unit Ground Source Heat Pump Cooling / Heating Hot
Product Specification
Payment Terms | T/T or L/C | Supply Ability | 5,000pcs per month |
Delivery Time | 10 working days after received your payment | Packaging Details | Plywood |
Product Name | Total Heat Recovery Unit Modular Air-Cooled Heat Pump | Cooling Capacity(kW) | 58 |
Heating Capacity(kW) | 63 | Max outgoing water temp.( °C) | 55 |
Refrigerant | R22 | Circuit water pump | Optional |
Heat recovery capacity KW | 70.5 | Brand Name | EuroKlimat |
Model Number | EKAC | Certification | ISO9001, ISO14001, OHSAS18001, CRAA, CQC |
Place of Origin | China | ||
High Light | air heat recovery unit ,waste heat recovery unit |
Low-Temperature High Efficiency Total Heat Recovery Unit Modular Air-Cooled Heat Pump
Specifications
Model | EKAC 210BRLHR |
EKAC 420BRLHR |
EKAC 360BRLHR |
EKAC 840BRLHR |
EKAC 1050BRLHR |
EKAC 1260BRLHR |
||
Air conditioning mode | Nominal cooling capacity | kW | 58 | 116 | 174 | 232 | 290 | 348 |
Nominal heating capacity | kW | 63 | 126 | 189 | 252 | 315 | 378 | |
Total power of nominal cooling capacity | kW | 16 | 32 | 48 | 64 | 80 | 96 | |
Total power of nominal heating capacity | kW | 17 | 34 | 51 | 68 | 85 | 102 | |
Water flow rate for nominal cooling capacity |
3 m /h |
10 | 20 | 30 | 40 | 50 | 60 | |
Water flow rate for nominal heating capacity |
3 m /h |
10.8 | 21.6 | 32.4 | 43.2 | 54.0 | 64.8 | |
Hot water mode | Nominal water flow | m3/h | 13.2 | 26.4 | 39.6 | 52.8 | 66 | 79.2 |
Nominal heating capacity | kW | 77 | 154 | 231 | 308 | 385 | 462 | |
Total power of nominal heating capacity | kW | 19 | 38 | 57 | 76 | 95 | 114 | |
Cooling + Heat recovery mode | Nominal cooling capacity | kW | 57 | 114 | 171 | 228 | 285 | 342 |
Nominal heat recovery capacity | kW | 70.5 | 141.0 | 211.5 | 282.0 | 352.5 | 423.0 | |
Total nominal power | kW | 13.5 | 27.0 | 40.5 | 54.0 | 67.5 | 81.0 | |
Nominal water supply capacity at heat recovery side | 3 m /h |
13.2 | 26.4 | 39.6 | 52.8 | 66.0 | 79.2 | |
Nominal water flow at evaporator side |
3 m /h |
10.3 | 20.6 | 30.9 | 41.2 | 51.5 | 61.8 | |
Power supply | 380V/3N~/50Hz | |||||||
Flow control | Electronic expansion valve | |||||||
Refrigerant | R22 | |||||||
Heat exchanger type |
Air conditioning side | braze-welded panel-type heat exchanger | ||||||
Hot water side | High-efficiency bucket heat exchanger | |||||||
Compressor | Type | High-efficiency bucket heat exchanger | ||||||
Lubricant | LubricantMineral oil (SUNISO 3GS) | |||||||
Qty. | Set | 2 | 4 | 6 | 8 | 10 | 12 | |
Fan | Type | |||||||
Qty. | Set | 2 | 4 | 6 | 8 | 10 | 12 | |
Water resistance | Air conditioning side | kPa | 45 | 45 | 45 | 45 | 45 | 45 |
Hot water side | kPa | 65 | 65 | 65 | 70 | 70 | 70 | |
Minimum diameter for water pipes | Air conditioning side | inch | ≥2 | ≥2-1/2 | ≥3 | ≥4 | ≥4 | ≥5 |
Hot water side | inch | ≥2-1/2 | ≥3 | ≥4 | ≥4 | ≥5 | ≥5 | |
Dimensions | L x H | mm | 2012x1840 | |||||
Width | 880 | 2125 | 3370 | 4615 | 5860 | 7015 | ||
Power cable specification | Section area of live line | mm2 | ≥10 | ≥35 | ≥70 | ≥95 | ≥120 | ≥150 |
Qty. of live lines | 3 | |||||||
Section area of null line | mm2 | ≥4 | ||||||
Qty. of null lines | 1 | |||||||
Section area of grounding line | mm2 | ≥10 | ≥16 | ≥35 | ≥50 | ≥60 | ≥75 | |
Qty. of grounding lines | 1 | |||||||
Net weight | kg | 610 | 1220 | 1830 | 2440 | 3050 | 3660 | |
Operation weight | kg | 630 | 1260 | 1890 | 2520 | 3150 | 3780 |
Note:
■ Air conditioning mode: Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172 m3/(h·kW);
outdoor ambient temperature 35°C. Test conditions for nominal heating capacity: outlet water temperature: 45°C; water flow: 0.172m3/(h·kW);
temperature of outdoor dry/wet bulb: 7°C/6°C.
■ Cooling + Heat recovery mode Test conditions for nominal cooling capacity: Hot water side: Outlet water temp. 45°C; nominal water flow for hot water mode.
Air conditioning side: Outlet water temp. 7°C; nominal water flow for heating mode.
■ Hot water mode: Test conditions for nominal water flow: temperature of outdoor dry/wet bulb: 20/15°C; Temperature of inlet/outlet water: 50/55°C.
■ Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter.
■ Water resistance at the hot water side includes water pressure drop of the unit and does not include the pressure drop at the Y-shaped filter and other components.
■ Pipes outside the unit need to be customized and installed on site. The diameter of the pipes must meet design requirements. EK does not provide the pipes.
■ Full heat recovery units and other units can be combined to form partial heat recovery modular system. Full heat recovery units can also be combined to form a
total heat recovery system. Modular units can be formed using the 1~16 basic modules. The above table lists the parameters for common module combinations.
Efficient Components and Optimized System Design
The EKAC series low-temperature high efficiency total heatrecovery modular air-cooled heat pump unit features stateof-the-art enhanced vapor injection (EVI) technologies, increasing refrigerant recycle by 20%. The evaporation capacity is improved by mid-pressure refrigerant intake. One compressor compresses refrigerant 2 times in each cycle.Half-M fins are used to improve the heat-exchange efficiency
of the heat exchanger. The unit features state-of-the-art cross diagonal convection angles for stainless steel braze-welded panel-type heat exchanger and stainless steel braze-welded panel-type economizer (used to increase the enthalpydifferentiation between the inlet and outlet of the evaporator). An EXV is used to precisely control the operation of the unit. Leading-edge Technology and Stronger
Cooling and Heating Capacities
The EKAC low-temperature high-efficiency modular aircooled heat pump unit features excellent heating COP
when the ambient temperature is low (20% higher than common air-cooled heat pump unit when the ambient
temperature is -10°C).The lower ambient temperature limit is expanded from -10°C of common units to -20°C. This greatly improves cooling performance in areas where the winter is cold, reducing or eliminating the need for auxiliary heaters.
Efficient and Energy Saving
Each modular unit has two power gears. When multiple modular units are combined, there could be many power gears. When working at a partial workload (99% of the operation time), the unit intelligently regulates the output based on the actual workload, making the operation efficiency even higher. With an optional 2-way valve water control feature, the unit can send out signals to cut off chilled water. This enables automatic flow control for pumps in line with the transducer, which helps save more energy.
Operation in Low Temperature Areas
The EKAC series low-temperature high-efficiency total heatrecovery unit features state-of-the-art EVI enthalpy increase technologies, and can provide effective heating and sufficient hot water when the ambient temperature is as low as -20°C. The unit can provide effective heating for areas that are extremely code in winter.
Safe and Comfortable
fast heating; hot water available as soon as you turn on the tap; absolutely safe as there is no emission of
harmful gas and the risk of electric shock is eliminated by separating water and electricity. The central hot water system can provide hot water with a stable temperature for multiple outlets, making bathing comfortable.
Lower Investment
Investments can be made in installments as the project rolls out. This reduces initial investment for new projects and making renovation project easy to complete.
Hybrid Connection Technology
Units of this series support modular connection with common air-cooled heat pump units to meet various
heat recovery requirements.
Smart Control
Units of this series are controlled by microcomputers. Each control module can control up to 16 units, making
unit combination easier. Temperature and level of water in the water tank are controlled automatically, and the
water pump starts/stops automatically. No dedicated operator is required, reducing the management cost by
easy smart control.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Seller,Other
Year Established:
1963
Total Annual:
>150 milion
Employee Number:
>1000
Ecer Certification:
Active Member
EUROKLIMAT (EK) was established in 1963 in Italy. For the past half a century, it has become famous as an energy-saving air-conditioning manufacturer in Italy and globally. Continuous innovation, new product development and top manufacturing quality are the driving... EUROKLIMAT (EK) was established in 1963 in Italy. For the past half a century, it has become famous as an energy-saving air-conditioning manufacturer in Italy and globally. Continuous innovation, new product development and top manufacturing quality are the driving...
Get in touch with us
Leave a Message, we will call you back quickly!