China factories

China factory - Tunkia Co., Ltd.

Tunkia Co., Ltd.

  • China
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter
China TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

  1. China TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

  1. MOQ: negotiation
  2. Price: Negotiation
  3. Get Latest Price
Name Fluke Multifunction Calibrator
Accuracy 0.02% ; 0.05%
Origin China
Application Clamp ammeters
Features wide range, multi value and high precision
Model TD1050A
Packaging Details Standard
Payment Terms negotiation
Place of Origin China
Brand Name TUNKIA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Name Fluke Multifunction Calibrator Accuracy 0.02% ; 0.05%
Origin China Application Clamp ammeters
Features wide range, multi value and high precision Model TD1050A
Packaging Details Standard Payment Terms negotiation
Place of Origin China Brand Name TUNKIA
TD1050A Calibration Device for Clamp Meter
 

Introduction

  • TD1050A, a calibration device for clamp ammeters. The optional accuracy are 0.02% and 0.05%.

  • The device calibrates the AC/DC clamp ammeters by single coil with high accuracy and easy traceability, and has the functions of AC/DC current output, resistance simulation, frequency/phase adjustment, power detection.

  • Meet the requirements of JJF 1075-2015 Calibration Specification for Clamp Ammeter. (Tunkia is involved in drafting)

Features

  • Calibrate AC/DC clamp ammeters by single coil: The AC/DC current source connect to a single coil semi-circular copper ring with a diameter of 1m, can directly output AC/DC high current up to 2200 A (or 1100 A). Suitable for calibrating AC/DC clamp ammeters with high accuracy.

  • Place the clamp meter in the center of the copper ring when calibrating. The diameter of the copper bar in the center position is smaller than the other positions, which is convenient for the access of small size clamp meters.

  • Easy to open the copper ring, and thread a standard current transformer or I-V converter into the ring for calibrating the device itself regularly.

  • Reserved terminals for high current, to provide current for the calibration of DC shunts.

  • Value Adjustment Method: Fixed-point, rotary encoder, and step.

  • Frequency and Phase (Option): The AC output frequency and the phase between voltage and current is variable.

  • Power Output (Option): Test DC power, active power, reactive power, apparent power and power factor.

  • Proprietary Software (Option): Support the calibration of the checked ammeters by semi-automatic or full-automatic, data management and report export.

Application

Calibrated Types

Accuracy of Calibrated Device

0.02% Calibrator

0.05% Calibrator

AC/DC Ammeters

0.1 and below

0.2 and below

AC/DC Voltmeters

0.1 and below

0.2 and below

DC Resistance

0.2 and below

0.2 and below

AC/DC Power

0.2 and below

0.5 and below

DC Shunts

0.1 and below

0.2 and below

 

Specification

 

AC Voltage Output

Range Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)①

Max. Load

Current (mA)

0.02% 0.05% 0.02% 0.05%
10 V 0.005 0.01 120 + 80 300 + 200 800
30 V 0.005 0.01 120 + 80 300 + 200 700
100 V 0.005 0.01 120 + 80 300 + 200 200
300 V 0.005 0.01 120 + 80 300 + 200 70
750 V 0.005 0.01 120 + 80 300 + 200 30
Remarks: ①: RD is the reading,RG is the range
  • Output Range of Voltage: 1 V ~ 825 V

  • Display: 6 digits

  • Resolution: 0.002 %*RG

  • Distortion: <0.5 %

  • Protection: Short-circuit protection, overload protection, overheating protection.

 

AC Current Output

Model Range Resolution Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load

Voltage (V)

0.02% 0.05% 0.02% 0.05%
Small current loop 100 mA 1 μA 0.01 0.01 120 + 80 300 + 200 10
300 mA 1 μA 0.01 0.01 120 + 80 300 + 200 10
1 A 10 μA 0.01 0.01 120 + 80 300 + 200 10
3 A 10 μA 0.01 0.01 120 + 80 300 + 200 10
10 A 100 μA 0.005 0.01 120 + 80 300 + 200 10
30 A 100 μA 0.005 0.01 120 + 80 300 + 200 5
100 A 1 mA 0.005 0.01 120 + 80 300 + 200 5
High current loop 250 A 1 mA 0.01 0.01 120 + 80 300 + 200 7
500 A 1 mA 0.01 0.01 120 + 80 300 + 200 7
1000 A 10 mA 0.005 0.01 120 + 80 300 + 200 7
2000 A② 10 mA 0.005 0.01 120 + 80 300 + 200 7
Remarks: ②: 2100 A for option
  • Output Range of Current: 10 mA ~ 1100 A (2100 A);

  • Range Switching: Automatic or Manual

  • Resolution: 0.002 %*RG

  • Distortion: <0.5 % (except 1 kA/2 kA); <1 % @ 1 kA/2 kA range

  • Protection: Short-circuit protection, overload protection, overheating protection.

 

Frequency

Type Range Adjust fineness Accuracy (k = 2)
Frequency

40.000 Hz ~ 400.000 Hz

(1 kHz can be customized)

0.001 Hz 0.005%*RD

 

DC Voltage Output

Range Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load

Current (mA)

0.02% 0.05% 0.02% 0.05%
200 mV 0.005 0.01 120 + 80 300 + 200 100
1 V 0.005 0.01 120 + 80 300 + 200 100
10 V 0.005 0.01 120 + 80 300 + 200 100
30 V 0.005 0.01 120 + 80 300 + 200 600
100 V 0.005 0.01 120 + 80 300 + 200 200
300 V 0.005 0.01 120 + 80 300 + 200 60
600 V 0.005 0.01 120 + 80 300 + 200 25
1000 V 0.005 0.01 120 + 80 300 + 200 20
  • Output Range of Voltage: 20 mV to 1100 V

  • Resolution: 0.002 % of range

  • Ripple Coefficient: <1 %

  • Protection: Short-circuit protection, overload protection, overheating protection.

 

DC Current Output

Model Range Resolution Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load

Voltage (V)

0.02% 0.05% 0.02% 0.05%
Small current loop 100 mA 1 μA 0.005 0.01 150 + 50 300 + 100 10
300 mA 1 μA 0.005 0.01 150 + 50 300 + 100 10
1 A 10 μA 0.005 0.01 150 + 50 300 + 100 10
3 A 10 μA 0.005 0.01 150 + 50 300 + 100 10
10 A 100 μA 0.005 0.01 150 + 50 300 + 100 10
30 A 100 μA 0.005 0.01 150 + 50 300 + 100 5
100 A 1 mA 0.005 0.01 150 + 50 300 + 100 5
High current loop 250 A 1 mA 0.005 0.01 150 + 50 300 + 100 5
500 A 1 mA 0.005 0.01 150 + 50 300 + 100 5
1000 A 10 mA 0.005 0.01 150 + 50 300 + 100 5
2000 A② 10 mA 0.005 0.01 150 + 50 300 + 100 5
Remarks: ②: 2100 A for option
  • Output Range of Voltage: 20 mA ~ 1100 A (2100 A);

  • Resolution: 0.002 %*RG

  • Range Switching: Automatic or Manual

  • Distortion: <0.5 % (except 1 kA/2 kA); <1 % @ 1 kA/2 kA range

  • Protection: Short-circuit protection, overload protection, overheating protection.

 

Power Output (Option)

Type Range Accuracy (k = 2), (%*FS)③
0.02% 0.05%
DC Power Combination of DC voltage and current range. 0.05 0.1
Active Power |cosφ|≥0.5 Combination of AC voltage and current range. 0.05 0.1
0.5 0.05 0.1
Reactive Power |sinφ|≥0.5 0.05 0.1
Power Factor -1.0000…0.0000…+1.0000 0.05 0.1
0.05 0.1
Remark: ③: FS = Voltage range × Current range

 

Resistance

Range Resolution Allowable Current

Accuracy (k = 2)

(ppm*RD + ppm*RG)

100 Ω 1 mΩ 300 + 200 300 + 200
1 kΩ 10 mΩ 300 + 200 300 + 200
10 kΩ 100 mΩ 300 + 200 300 + 200
100 kΩ 1 Ω 300 + 200 300 + 200
1 MΩ 10 Ω 300 + 200 300 + 200
10 MΩ 100 Ω 600 + 400 600 + 400
100 MΩ 1 kΩ 10 nA ~ 50 nA 3000 + 2000
  • Output Range of Resistance: 10 Ω ~ 110 MΩ

  • Display: 6 digits

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller,Other

  • Year Established:

    1998

  • Employee Number:

    300~500

  • Ecer Certification:

    Verified Supplier

TUNKIA Co., Ltd. is a unique company with top R&D strength in electromagnetics in China. Since its founding in 1998, Tunkia focus on electromagnetic measurement technology, gathered more than 400 personnel all over the world. At present, Tunkia has launched 32 categories and over 500 advanced el... TUNKIA Co., Ltd. is a unique company with top R&D strength in electromagnetics in China. Since its founding in 1998, Tunkia focus on electromagnetic measurement technology, gathered more than 400 personnel all over the world. At present, Tunkia has launched 32 categories and over 500 advanced el...

+ Read More

Get in touch with us

  • Reach Us
  • Tunkia Co., Ltd.
  • http://www.tunkia.cn/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement