Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Wide Range Fluke Multi Calibrator High Precision Multi Value TD1880","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/c5\/1b\/00e40e0e2060681ea613795be65d-200x200-1\/wide_range_fluke_multi_calibrator_high_precision_multi_value_td1880.jpg","attrs":{"Model Number":"TD1880","Place of Origin":"China","Brand Name":"TUNKIA","Minimum Order Quantity":"negotiation"}}
{"title":"High Precision Fluke Multifunction Calibrator TD1880 For Electrical Measuring","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/3f\/94\/550d08acffc9ce4af727670a2a98-200x200-1\/high_precision_fluke_multifunction_calibrator_td1880_for_electrical_measuring.jpg","attrs":{"Place of Origin":"China","Brand Name":"TUNKIA","Minimum Order Quantity":"negotiation","Price":"negotiation"}}
{"title":"TD1600 Fluke Multifunction Calibrator High Precision Single Phase AC Calibrator","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/eb\/79\/b8e5536c61ac1e12b172c7049f07-200x200-1\/td1600_fluke_multifunction_calibrator_high_precision_single_phase_ac_calibrator.jpg","attrs":{"Model Number":"TD1600","Name":"Fluke Multifunction Calibrator","Features":"wide range, multi value and high precision","Accuracy":"0.02% ; 0.05%"}}
{"title":"TD1880 Fluke Multifunction Calibrator High Precision Multi Product Calibrator","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/ec\/fc\/a1ceac2edeea48e82c86d8e0c4b4-200x200-1\/td1880_fluke_multifunction_calibrator_high_precision_multi_product_calibrator.jpg","attrs":{"Place of Origin":"China","Brand Name":"TUNKIA","Minimum Order Quantity":"negotiation","Price":"negotiation"}}
{"title":"Single Phase AC Voltage Calibrator 45Hz - 70Hz Precision Calibrator TD1600","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/83\/87\/449c485bbc377a003eeae49d55af-200x200-1\/single_phase_ac_voltage_calibrator_45hz_70hz_precision_calibrator_td1600.jpg","attrs":{"Model Number":"TD1600","Name":"Fluke Multifunction Calibrator","Features":"wide range, multi value and high precision","Accuracy":"0.02% ; 0.05%"}}
{"title":"TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/a4\/a5\/3eaa5cc289349c95c6f53f537de9-200x200-1\/td1050a_calibration_device_easy_traceability_for_ac_dc_clamp_meter.jpg","attrs":{"Name":"Fluke Multifunction Calibrator","Accuracy":"0.02% ; 0.05%","Origin":"China","Application":"Clamp ammeters"}}
{"title":"AC Electrical Power Calibrator TA2100 Multi Value High Precision","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/35\/5b\/0d6076322614f75bb607e23dd5d7-200x200-1\/ac_electrical_power_calibrator_ta2100_multi_value_high_precision.jpg","attrs":{"Model Number":"TA2100","Name":"Fluke Multifunction Calibrator","Features":"wide range, multi value and high precision","Application":"Clamp ammeters"}}
TD1880, a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC/DC voltage, current, phase adjustment and power, and also has the functions of pulse output and simulating DC resistance, thermocouple (TC), thermal resistance (RTD) and capacitance. Applied to calibrate 6 and below digits multimeters or other electrical measuring instruments.
Reference
JJG 124-2005 Verification Regulation of Amperemeters, Voltmeters, Wattmeters and Ohmmeters.
JJF 1587-2016 Calibration Specification for Multimeters
JJF 1284-2011 Calibration Specification of Calibrators for Electrical Meters
JJF 1638-2017 Calibration specification of multifunctional standard source
Features
Electrical Parameters Output: Voltage is up to 1100 V, current is up to 30 A at a frequency 10 Hz ~ 500 kHz.
The output current has high stability (the typical value is better than 10 ppm/h) and high accuracy (the typical value is 50 ppm/a), and its measurement accuracy is higher than the international similar products.
Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).
Output Switch: The output can be turned on/off arbitrarily by one-touch operation.
TC and RTD simulation: Support for simulation of up to 8 types of TC and 6 types of RTD.
Strong load capacity of AC, can drive various types of analogue meters and digital meters, so the applicable range of measured instruments is very wide.
The protection of voltage and current sources ensures high reliability under complex conditions.
Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.
Transmitter Measurement (Option): Measure the secondary DC signal of the transmitters.
Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.
Combination of DC voltage range and DC current range.
Accuracy
DC voltage accuracy + DC current accuracy.
AC Power
(45 Hz ~ 65 Hz)
Range
Combination of 30 V...300 V range and 10 mA…30 A range.
Accuracy
Range of 10 mA…30 mA: 0.05 %*FS
Range of 100 mA…30 A: 0.02 %*FS
Power Factor
-1.0000…0.0000…+1.0000
Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)
Capacitance
Range
Accuracy (k = 2) (%*RD+ nF or μF)
Resolution
Allowable Frequency
1.1 nF ~ 3.2999 nF
0.5 + 0.04 nF
0.1 pF
10 Hz ~ 3 kHz
3.3 nF ~ 10.9999 nF
0.25 + 0.04 nF
0.1 pF
10 Hz ~ 1 kHz
11 nF ~ 32.9999 nF
0.25 + 0.4 nF
0.1 pF
10 Hz ~ 1 kHz
33 nF ~ 109.999 nF
0.25 + 0.4 nF
1 pF
10 Hz ~ 1 kHz
110 nF ~ 329.999 nF
0.25 + 0.3 nF
1 pF
10 Hz ~ 1 kHz
330 nF ~ 1.09999 μF
0.25 + 1 nF
10 pF
10 ~ 600 Hz
1.1 μF ~ 3.29999 μF
0.25 + 3 nF
10 pF
10 ~ 300 Hz
3.3 μF ~ 10.9999 μF
0.25 + 10 nF
100 pF
10 ~ 150 Hz
11 μF ~ 32.9999 μF
0.40 + 30 nF
100 pF
10 ~ 120 Hz
33 μF ~ 109.999 μF
0.45 + 100 nF
1 nF
10 ~ 80 Hz
110 μF ~ 329.999 μF
0.45 + 300 nF
1 nF
0 ~ 50 Hz
330 μF ~ 1.09999 mF
0.45 + 1 μF
10 nF
0 ~ 20 Hz
1.1 mF ~ 3.29999 mF
0.45 + 3 μF
10 nF
0 ~ 6 Hz
3.3 mF ~ 10.9999 mF
0.45 + 10 μF
100 nF
0 ~ 2 Hz
11 mF ~ 30 mF
0.75 + 30 μF
100 nF
0 ~ 0.6 Hz
Resistance
Range
Allowable Current
Accuracy (k = 2), ppm*RD +Ω
24 Hours
90 Days
1 Year
10 Ω
1 mA ~ 150 mA
20 + 0.01
32 + 0.01
40 + 0.01
20 Ω
1 mA ~ 150 mA
15 + 0.015
24 + 0.015
30 + 0.015
100 Ω
1 mA ~ 80 mA
12 + 0.015
20 + 0.015
25 + 0.015
300 Ω
1 mA ~ 40 mA
12 + 0.02
20 + 0.02
25 + 0.02
1 kΩ
1 mA ~ 20 mA
12 + 0.02
20 + 0.02
25 + 0.02
3 kΩ
0.1 mA ~ 6 mA
12 + 0.2
20 + 0.2
25 + 0.2
10 kΩ
0.1 mA ~ 2 mA
12 + 0.2
20 + 0.2
25 + 0.2
30 kΩ
10 μA ~ 600 μA
15 + 1
24 + 1
30 + 1
100 kΩ
10 μA ~200 μA
15 + 1
24 + 1
30 + 1
300 kΩ
1 μA ~ 60 μA
17 + 10
28 + 10
35 + 10
1 MΩ
1 μA ~ 20 μA
17 + 10
28 + 10
35 + 10
3 MΩ
250 nA ~ 6 μA
30 + 150
48 + 150
60 + 150
10 MΩ
250 nA ~ 2 μA
65 + 250
104 + 250
130 + 250
30 MΩ
25 nA ~ 600 nA
125 + 2.5 k
200 + 2.5 k
250 + 2.5 k
100 MΩ
25 nA ~ 200 nA
250 + 3 k
400 + 3 k
500 + 3 k
300 MΩ
2.5 nA ~ 60 nA
1,5 k + 0.1 M
2.4 k + 0.1 M
3 k + 0.1 M
1000 MΩ
1 nA ~ 20 nA
7.5 k + 0.5 M
12 k + 0.5 M
15 k + 0.5 M
Output Range of Resistance: 0 Ω ~ 1100 MΩ; Resolution: 0.0004 %*RG; Display: 7 digits
Thermal Resistance (RTD)
Type
Temperature Range (°C)
Accuracy (k = 2) (°C)
90 Days
1 Year
Pt385, 100 Ω
-200 ~ 0
0.05
0.05
0 ~ 300
0.08
0.08
300 ~ 850
0.12
0.12
Pt385,200 Ω
-200 ~ 250
0.04
0.04
250 ~ 630
0.10
0.15
Pt385,500 Ω
-200 ~ -30
0.36
0.40
-30 ~ 630
0.10
0.11
Pt385,1000 Ω
-200 ~ 0
0.027
0.03
0 ~ 300
0.054
0.060
300 ~ 600
0.063
0.070
CU50
-50 ~ 150
0.09
0.09
CU100
-50 ~ 150
0.045
0.045
Thermocouple (TC)
Type
Temperature Range (°C)
Accuracy (k = 2) (°C)
90 Days
1 Year
B
410 ~ 600
0.30
0.35
600 ~ 900
0.30
0.31
900 ~ 1800
0.26
0.30
E
-200 ~ 0
0.10
0.11
0 ~ 600
0.07
0.08
600 ~ 1000
0.09
0.10
J
-200 ~ -100
0.12
0.13
-100 ~ 750
0.09
0.09
750 ~ 1200
0.10
0.10
K
-200 ~ -100
0.15
0.20
-100 ~ 1000
0.10
0.10
1000 ~ 1370
0.12
0.12
N
-200 ~ -100
0.20
0.25
-100 ~ 400
0.12
0.12
400 ~ 1300
0.10
0.12
R
-50 ~ 50
0.30
0.40
50 ~ 300
0.28
0.32
300 ~ 1000
0.22
0.23
1000 ~ 1750
0.25
0.25
S
-50 ~ 50
0.30
0.40
50 ~ 300
0.31
0.34
300 ~ 1000
0.24
0.24
1000 ~ 1750
0.22
0.23
T
-200 ~ -100
0.17
0.25
-100 ~ 0
0.08
0.11
0 ~ 400
0.08
0.08
Pulse
Frequency Range: 1 Hz ~ 2 MHz, TTL Level
Resolution: 0.001 %*RG
Accuracy: ±(0.002 %*RD + 20 μHz)
Jitter: <20 ns
DC Small Signal Measurement (Option)
Range: 1 V, 10 V, 2 mA, 20 mA
Measuring Range: ± (0 ~12 V);± (0 ~ 24 mA)
Accuracy: ±(0.006 %*RD + 0.004 %*RG)
Notes: Applied to measure the secondary DC signal of the transmitters.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Seller,Other
Year Established:
1998
Employee Number:
300~500
Ecer Certification:
Verified Supplier
TUNKIA Co., Ltd. is a unique company with top R&D strength in electromagnetics in China. Since its founding in 1998, Tunkia focus on electromagnetic measurement technology, gathered more than 400 personnel all over the world. At present, Tunkia has launched 32 categories and over 500 advanced el... TUNKIA Co., Ltd. is a unique company with top R&D strength in electromagnetics in China. Since its founding in 1998, Tunkia focus on electromagnetic measurement technology, gathered more than 400 personnel all over the world. At present, Tunkia has launched 32 categories and over 500 advanced el...