China factories

China factory - Wuxi Superclean Equipment CO., LTD

Wuxi Superclean Equipment CO., LTD

  • China
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China PLC None Dust Prefabricated Free Room Sandwich Board Clean Sanitizer Cleanroom
China PLC None Dust Prefabricated Free Room Sandwich Board Clean Sanitizer Cleanroom

  1. China PLC None Dust Prefabricated Free Room Sandwich Board Clean Sanitizer Cleanroom

PLC None Dust Prefabricated Free Room Sandwich Board Clean Sanitizer Cleanroom

  1. MOQ: 1 Set
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 1 Plant/Plants per Month
Delivery Time 14-30 Workdays
Packaging Details wooden packge
Core Components: PLC, Motor
Filter efficiency: 0.9999
Function: Electronic clean room
Floor: PVC\Epoxy Floor
Showroom Location: None
After Warranty Service: Online support
Certification CE, ISO, UL
Place of Origin Jiangsu, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 1 Plant/Plants per Month Delivery Time 14-30 Workdays
Packaging Details wooden packge Core Components: PLC, Motor
Filter efficiency: 0.9999 Function: Electronic clean room
Floor: PVC\Epoxy Floor Showroom Location: None
After Warranty Service: Online support Certification CE, ISO, UL
Place of Origin Jiangsu, China
High Light PLC None Dust Free Roomsandwich board Dust Free Clean RoomPrefabricated Sanitizer Cleanroom

E-Clean Dust-Free Cleanrooms

E-Clean builds and designs dust-free cleanrooms ranging from FS209E levels 100 to 100,000, which equate to ISO 14644 levels 5 to 8. For 300,000-level cleanrooms, a sub HEPA filter may be used. For levels 100-100,000, we recommend installation of a system of primary, secondary, and high-efficiency HEPA filters. The airflow rates of the secondary and high-efficiency filters should be less than or equal to the specified airflow rate of the cleanroom. Secondary filters should be concentrated around the barotropic section of the air handling system, while the high-efficiency filters should be concentrated around the end of the air handling system

 

 

 

Additional Considerations for Dust-Free Cleanrooms

Dust-free cleanrooms maintain a positive pressure environment and control the number of dust particles in the air via an advanced filtration system. In addition to the filtration system, the level of cleanliness in a cleanroom is determined by internal and external environmental factors, such as the amount of people and equipment contained within the cleanroom and the amount of traffic passing through the room. The amount of air changes per hour (air change rate or ACR), air velocity, method of airflow, fan size and fan speed are just some of the variables that we consider when designing a world-class cleanroom solution for your enterprise.

 

Our dust-free cleanroom series can be designed and built to suit clients who require high-quality air filtration in the electronics, semiconductor, precision fabrication, LCD manufacturing, optics, circuitry, and other related industries.

 

 

lmportant Practices for Maintaining your Cleanroom
(1) When cleaning the walls of your cleanroom, use ESD cleanroom wipes.
(2) Use a solution of 90% deonized water and 10% isopropyl alcohol for surface cleaning.(3)Only use detergents that have been approved for use in cleanroom environments.(4) Make sure to remove all garbage and other waste from the cleanroom daily.
(5) Regularly vacuum your cleanroom, and keep a log of all cleaning and vacuuming activities in your cleanroom with a "CeanroomCleaning Log" that indludes columns for name, time and area cleaned.
(6) When cleaning the floor of your cleanroom, make sure to shut off the air purification system and use a mop approved for use incleanrooms.
(7) When vacuuming your cleanroom, use a vacuum that contains a HEPA filter.(8) Regularly clean and maintain all windows and doors.
(9) Vacuum and mop your dleanroom daily; and clean walls, windows, and doors weekly.(10)The undersurfaces of elevated floors must also be cleaned regularly.
(11) Clean the columns and supports of elevated floors once every quarter.
(12) When wiping surfaces, always wipe downwards. Start cleaning your cleanroom from the location farthes
t from the entrance,
moving towards the entrance as you clean.

 

 

Dust-Free Cleanroom Management System
(1) Purpose: Enact a management system for the production process that will alow supervision and management of cleanliness whilepreventing contact with contaminants in order to have a significant positive effect on product quality.
(2) Scope: Applicable to anyone or any thing that comes in or around the cleanroom or related facilities.(3) Working Procedures:
(a) Employees with access to the cleanroom are required to take a physical exam and produce proof of gooc
health annually.
(b)The number of people in the cleanroom at any time may not exceed the quotient of (total are in square meters / 4).
(c) Refer to "Cleanroom Area Apparel Management System " for information about the apparel allowed in the cleanroom.(d)Disinfect the cleanroom with UV light for one hour daily when the cleanroom is unoccupied. Disinfect with formaldahydefumigation for 30 minutes once per month. Keep a log of both of these activities.
(e) All people entering and exiting the cleanroom must follow the procedures outlined below:
Enter Controlled Area-Remove Shoes→Remove Clothing=→Wash Hands→Put on Cleanroom Apparel→Disinfect Hands→AirShower→Enter Cleanroom
Approach Cleanroom Exit-→Exit Cleanroom→Remove Cleanroom Apparel→Put on Original Clothes-Put on Shoes-Exit Controld Area(f)Designate one person to be responsible for stocking and replenishing hand disinfectant. Use 0.3% benzalkonium bromide hand
disinfectant.
(g) Employ pass bowes to transfer any material nto a cleanroom, whether from the outside environment or from one cleanroom toanother. This minimizes the amount of imes that the door to the deanroom is opened, which in turn minimizes air contaminants in thecleanroom.
(h) Sanitize all tables, workstations, benches, and the cleanroom floor daily. Clean the walls of the deanroom weekly, and keep adetailed log of all of these activities.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Total Annual:

    1000000-1000000

  • Ecer Certification:

    Active Member

With more than a decade of experience in the cleanroom and industrial purification equipment sectors, Wuxi Superclean Equipment CO., LTD. is an industry leading company located west of Shanghai in the city of Wuxi, Jiangsu, China. Our offers certified cleanroom design, manufacture, and installation ... With more than a decade of experience in the cleanroom and industrial purification equipment sectors, Wuxi Superclean Equipment CO., LTD. is an industry leading company located west of Shanghai in the city of Wuxi, Jiangsu, China. Our offers certified cleanroom design, manufacture, and installation ...

+ Read More

Get in touch with us

  • Reach Us
  • Wuxi Superclean Equipment CO., LTD
  • https://www.dustfreecleanroom.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!