Product Specification
Payment Terms | L/C, T/T | Supply Ability | 100 SETS/Month |
Delivery Time | within 30 days after order confirmation according to required qty | Packaging Details | polywood case, carton |
Material | porcelain | Rated voltage | 12KV |
Rated frequency | 50HZ | Rated current | 630HZ |
Brand Name | XK | Model Number | RH-B 11KV/630A |
Certification | ISO9001 / GB / IEC | Place of Origin | China |
High Light | transformer disconnect switch ,outdoor disconnect switch |
High-Voltage Protective Equipment
Gang-Operated, Air-Break Disconnect Switch Picture The first device encountered in a substation is typically a disconnect switch.
The most commonly used switch in small to medium substations is a gang-operated, air-break disconnect switch. "Gang-operated" because the three separate switches for each phase are operated as a group from a single control; "air-break" because the switch operates in air rather than in another medium, such as oil.
The purpose of this switch is to disconnect the substation from the incoming line, not to disconnect the transformer from the load. It is like a large safety switch with no load breaking capability. It can only break, or "interrupt" the relatively small "magnetizing current" of the substation transformer. (This is the small amount of current needed to set up the magnetic field in the transformer core.) A substation must first be disconnected from its secondary or load side before the primary or high voltage side can be disconnected using the disconnect switch. High Voltage Power Fuses Picture
Outdoor AC switch disconnector 11kv/400A - 33kv/600A used in 3 phase AC 50/60Hz power circuit, it is used as switching on and switching off at the voltage with no load. It apply to IEC standard. IEC60964:1996, IEC62271-102:2002.
Features:Manufacture according IEC standards.Up to 36kV,900A,200kV BIL.Three phase disconnector.Porcelain and polymer type insulator.Manual and electric drivers.
Company Details
Business Type:
Manufacturer
Year Established:
2011
Total Annual:
5M-10M
Employee Number:
>100
Ecer Certification:
Active Member
Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products. Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switch... Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products. Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switch...
Get in touch with us
Leave a Message, we will call you back quickly!