Supply Ability | 100 Piece/Pieces per Month |
Packaging Details | EXPORTING PACKING |
Type | Vacuum |
Poles Number | 3 |
Standard | GBJ, JB,IEC |
Rated Current | 630A,1250A, 1600A |
Rated Voltage | 11kv 33 Kv |
Mechanical life | 10000 |
keywords | 11kv/33kv 630a vacuum circuit breaker |
Port | NINGBO |
Place of Origin | Zhejiang, China |
Brand Name | XK |
Certification | ISO9001 / GB / IEC |
Model Number | ZN63-6137 |
View Detail Information
Explore similar products
12KV Ac Indoor Vcb Panel / Three Phase Vcb Breaker 630A 1250A 1600A Optional
12KV 24KV Outdoor Vcb Breaker High Voltage Three Phase IEC Standard
630A 12kV Vacuum Circuit Breaker / High Power Vac Breaker IEC Standard
High Efficiency Vacuum Type Circuit Breaker Outdoor Permanent Magnetic ZW32
Product Specification
Supply Ability | 100 Piece/Pieces per Month | Packaging Details | EXPORTING PACKING |
Type | Vacuum | Poles Number | 3 |
Standard | GBJ, JB,IEC | Rated Current | 630A,1250A, 1600A |
Rated Voltage | 11kv 33 Kv | Mechanical life | 10000 |
keywords | 11kv/33kv 630a vacuum circuit breaker | Port | NINGBO |
Place of Origin | Zhejiang, China | Brand Name | XK |
Certification | ISO9001 / GB / IEC | Model Number | ZN63-6137 |
High Light | vcb circuit breaker ,indoor vcb panel |
Vacuum Arc Recovery Phenomenon:
High vacuum possesses extremely high dialectic strength. At current zero the cathode spot extinguishes within 10–8 second and after this the original dielectric strength is established very soon. This quick return of high dielectric strength is, of course, due to the fact that the vaporized metal which is localized between the contacts, diffuses rapidly due to absence of gas molecules. The metal molecules are blown at high speeds to the glass walls and condense there. After arc interruption the recovery strength during the first few microseconds is 1 kV/µs for an arc current of 100 A, as compared with 50 V/µs in case of air gap.
Because of the attributes of vacuum interrupters, vacuum circuit breakers can be employed without reservations for fault clearing in any location on a system. They are capable of handling the severe recovery transients associated with short line faults or faults close to a transformer without any difficulty. All forms of load switching can be performed with the same ease.
Item | Unit | Data | |||
Rated voltage | KV | 12 | |||
Maximum working voltage | KV | 12 | |||
Rated Current | A | 630-1250 | 630-1600 | 630-1600 | |
Rated short circuit breaking current | KA | 20 | 25 | 31.5 | |
Rated short-circuit switching current | KA | 50 | 63 | 80 | |
Rated peak withstand current | KA | 50 | 63 | 80 | |
4S rated short-circuit withstand current | KA | 20 | 25 | 31.5 | |
Rated insulation level | 1min Power frequency withstand voltage | KV | 42(fracture 48) | ||
lmpulse withstand voltage | KV | 75(fracture 84) | |||
Rated short-circuit current breaking times | Times | 50 | |||
Rated Operating Mechanism Closing Voltage(DC) | V | AC,DC 110,220 | |||
Rated Operating Mechanism Opening Voltage(DC) | V | AC,DC 110,220 | |||
Contact opening distance | mm | 11±1 | |||
Overtravel(the length of contact spring compression) | mm | 3.5±0.5 | |||
Closing/Opening Time Difference Among Three Phase | ms | ≤2 | |||
Contact closing bounce time | ms | ≤2 | |||
Average opening speed | m/s | 0.9-1.2 | |||
Average closing speed | m/s | 0.5-0.8 | |||
Tripping Time | Maximum operating voltage | S | ≤0.05 | ||
Minimum operating voltage | S | ≤0.08 | |||
Closing time | S | 0.1 | |||
The main circuit resistance of each phase | 630≤50 | 1250≤45 | 1600≤40 | ||
Allowed Consumpted thickness of Contacts | mm | 3 |
Q1. Can we have our logo or company name to be printed on your products or the package?
Yes,you can.Logo and company name can be printed on our products by silk screen printing.You can send us the artwork by email in JPEG or TIFF format.
Q2. What is lead time?
Usually 3-15 working days, On-Time delivery
Q3. Why us?
All products comply with the requirements of GB national standards, IC, ANSI and other international standards, and the requirements of company's technology standards.
Q4. How do you make our business long-term and good relationship?
1. Our high quality and competitive price are the most important factors to maintain long-term and good relation -ship with our customers.
2. Good service is our basic principle for every customers.
Q5. Can I have a visit to your factory before the order?
Sure,welcome to visit our factory.
Company Details
Business Type:
Manufacturer
Year Established:
2011
Total Annual:
5M-10M
Employee Number:
>100
Ecer Certification:
Active Member
Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products. Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switch... Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products. Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switch...
Get in touch with us
Leave a Message, we will call you back quickly!