Payment Terms | L/C, T/T, Western Union |
Supply Ability | 100 sets per month |
Delivery Time | 10 working days |
Packaging Details | carton, wooden case |
Display mode | LCD display |
Product Name | Large screen patient monitor |
Battery type | Lithium battery 11.1V/4.4Ah |
Recharge time | ≥4 hour |
Use time | 3 hour |
Environment temperature | 5℃~+40℃ |
Brand Name | STATEMED |
Model Number | STT15-MPM44 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Automated Portable Multi Parameter Patient Monitor / All In One Vital Sign
Small Volume Electronic Vital Sign Machine , CHD Room Vital Sign Monitoring
7 Inch Mobile Multi Parameter Patient Monitor With High Definition LCD Screen
Blood Pressure Multi Parameter Patient Monitor Light Weight Medical Equipment
Product Specification
Payment Terms | L/C, T/T, Western Union | Supply Ability | 100 sets per month |
Delivery Time | 10 working days | Packaging Details | carton, wooden case |
Display mode | LCD display | Product Name | Large screen patient monitor |
Battery type | Lithium battery 11.1V/4.4Ah | Recharge time | ≥4 hour |
Use time | 3 hour | Environment temperature | 5℃~+40℃ |
Brand Name | STATEMED | Model Number | STT15-MPM44 |
Certification | CE | Place of Origin | CHINA |
High Light | patient monitoring equipment ,vital signs monitoring devices |
Best sell multi parameter medical patient monitor
Battery
Battery type | Lithium battery 11.1V/4.4Ah |
Recharge time | ≥4 hour |
Use time | 3hours |
Work Environment
Environment temperature | Working 5℃~+40℃ |
Relative humidity | Working ≤85% |
Atmospheric pressure | Working 700hpa~1060hpa |
ECG
Lead | Standard Three leads | R,L,F, lead mode :Ⅰ,Ⅱ,Ⅲ | |||
Standard Five leads | R,L,F,N,C, | ||||
Sensitivity | 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,40mm/mV,erro≤±3% | ||||
Scan speed | 12.5,25,50mm/s three level,erro ≤±10% | ||||
Adjustable screen aspect ratio | 0.05~3.2 | ||||
Lead off condition detected | U=2V I=0.04uA | ||||
Active noise suppression | In patients who have not applied current | ||||
Tall T-wave suppression | 1.4mV | ||||
Inner voice | <30μVP-P | ||||
Input impedance | ≥2.5MΩ | ||||
Input loop current | ≤0.1μA | ||||
Endure electrode polarizing voltage | ±300mV | ||||
ECG signal input range | ±5mV | ||||
Measurement mode | Diagnosis mode,monitoring mode,operation mode | ||||
Frequency property | diagnosis mode 0.05~130HZ | ||||
CMRR | Diagnosis mode ≥80dB | ||||
HR measurement range | Adult 30~250bpm | ||||
HR accuracy | ±2% | ||||
HR sensitivity | >200μV | ||||
Heart rate calculation | Take 4 to 12 R-wave cycle averaged | ||||
Refresh time heart rate | 1S | ||||
Heart rate response time | 80-120 BPM:range 4-7s | ||||
Alarm range | 0~301bpm,upper and lower limit can be adjusted continuously | ||||
Alarm indicator | Audial and visual alarm | ||||
Heart rate too fast startup time of the alarm | Range :4-6s | ||||
Protection | Isolated immunity voltage 4000V,50/60HZImmunity of electronic surgical Anti-defibrillation | ||||
Protection and recovery for defibrillation effect | In the monitor and the surgical model ,ECG waveforms recovery to baseline in 5S. | ||||
Electrode polarization recovery time after the fibrillation | In the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S. | ||||
Surgical interference of electrical recovery time | In the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S. | ||||
No overshoot pacemaker pulse suppression: | |||||
Extent±2mV~±700mV,Pulse width 0.1ms~2ms | QRS wave | Display | |||
a)Single pacing pulse | 60 | 60±2bpm | |||
30 | 30±2bpm | ||||
0 | -- | ||||
b)With normal QRS-T pacing the pacing pulse | 60 | 60±2bpm | |||
30 | 30±2bpm | ||||
0 | -- | ||||
c)QRS has an invalid pacing mode pacing pulse. In all cases, overshoot (a0) pacing rate should be less than 5% overshoot and settling time must be less than 5μs. Rise and fall time of the pulse width should be 10% but not more than 100μs, and the pacing pulse starting time should be the starting point in the QRS complex prior to or shorter than 40ms at 40ms. | 60 | 60±2bpm | |||
30 | 30±2bpm | ||||
0 | -- | ||||
Beware of the room pacing pulses have the same ventricular pacing pulse amplitude and duration, and ventricular pacing pulses than 150ms to 250ms in advance | 60 | 60±2bpm | |||
30 | 30±2bpm | ||||
0 | -- | ||||
Typical minimum input slew rate | 50V/s RTI |
Shipping:
A. If the quantity of the order is not very big, we could send to you by express delivery. Such as TNT, UPS, DHL, Fedex.
B. If the order is so big, we will advise you use Air Shipping or Sea Shipping through your nominated forwarder FOB China Port.
C. Freight collect if bulk shipment.
Certificate:
Welcome To STATEMED!
Professional supplier,your best choice!
Reasonal price,high quality!
Company Details
Business Type:
Manufacturer,Agent,Exporter,Trading Company,Seller
Year Established:
2002
Total Annual:
1-1.5 million
Employee Number:
1~200
Ecer Certification:
Active Member
State (Beijing) Medical Technology Co., Ltd. established in 2002, is a High-tech medical products enterprise combining R&D, production ,sales and after-sale together, specialized in Medical Ultrasonic Instruments, ENT Workstation, Medical Endoscope Imaging Systems, Colposcope, Spectral Instrumen... State (Beijing) Medical Technology Co., Ltd. established in 2002, is a High-tech medical products enterprise combining R&D, production ,sales and after-sale together, specialized in Medical Ultrasonic Instruments, ENT Workstation, Medical Endoscope Imaging Systems, Colposcope, Spectral Instrumen...
Get in touch with us
Leave a Message, we will call you back quickly!