Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 300 tons per month |
Delivery Time | 5-21 days |
Packaging Details | Spool package with Carton box, Coil package with polybag |
Product name | Thermocouple K extension wire |
Color | bright |
Certificate | ISO9001 |
Temperature range | 32 to 392F (0 to 200C) |
EMF tolerance | +/- 2.2C or +/- .75% |
Grade | Extension Grade Type K |
Positive | Ni-cr |
Negative | Ni-si |
Special Limits of Error | +/- 1.1C or 0.4% |
Brand Name | DLX |
Model Number | Type k Thermocouple extension wire |
Certification | CE,ROHS |
Place of Origin | China |
View Detail Information
Explore similar products
0.5mm Platinum Rhodium Type S Thermocouple Extension Wire
TP TN 0.1mm Copper Type T Thermocouple Extension Wire
0.12mm Thermocouple Extension Wire
Type J Thermocouple Extension Wire
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Supply Ability | 300 tons per month |
Delivery Time | 5-21 days | Packaging Details | Spool package with Carton box, Coil package with polybag |
Product name | Thermocouple K extension wire | Color | bright |
Certificate | ISO9001 | Temperature range | 32 to 392F (0 to 200C) |
EMF tolerance | +/- 2.2C or +/- .75% | Grade | Extension Grade Type K |
Positive | Ni-cr | Negative | Ni-si |
Special Limits of Error | +/- 1.1C or 0.4% | Brand Name | DLX |
Model Number | Type k Thermocouple extension wire | Certification | CE,ROHS |
Place of Origin | China | ||
High Light | Type B Thermocouple Extension Cable ,PVC Sheath Thermocouple Extension Cable ,Bright Thermocouple Extension Wire |
Type K / J / E / N / T / R / S / B Thermocouple Extension Cable with PVC Sheath for -20~100℃ Temperature Range
Thermocouple compensation wire temperature measurement principle
The function of compensating wires for thermocouples is to extend the thermoelectric electrode, that is, move the cold end of the thermocouple, and connect it with the display instrument to form a temperature measurement system. The product is mainly used in various temperature measurement devices and has been widely used in departments such as petroleum, chemical, metallurgy, and power.
Generally speaking, thermocouples may be several tens of meters away from the thermometer, and the temperature at the cold end (outlet) of the thermocouple is different from the ambient temperature of the thermometer (even up to several tens of degrees).
If ordinary copper wires are used, according to the principle of thermocouples, the junction will generate thermoelectric potential, which will result in measurement errors.
The voltage drop problem of long-distance transmission wires is due to the high input impedance of the thermometer, the small transmission current (micro A level) generated by the thermocouple (millivolt level), and the small voltage drop loss on the wire, which is generally within the error range. So there is a thermocouple transmitter that inputs thermocouple signals and outputs 4-20mA, which allows for long-distance transmission without compensating for wires.
If a compensating wire is used (which must match the thermocouple graduation number), the metal material used can generate the smallest possible thermoelectric potential at the wiring point and minimize temperature measurement errors as much as possible. That is to say, move the cold end of the thermocouple to the thermometer.
Equipped with thermoelectric Even graduation number |
common(G)
|
heat resistant(H)
|
||
Common
|
Precision(S)
|
Common
|
Precision(S)
|
|
S
|
SC-G
|
SC-GS
|
SC-H
|
--
|
N
|
NC-G
|
NC-GS
|
NC-H
|
NC-HS
|
K
|
NC-G
|
NC-GS
|
NC-H
|
--
|
KC2-G
|
KG2-GS
|
KC2-H
|
KC2-HS
|
|
KX-G
|
KX-GS
|
KX-H
|
KX-HS
|
|
E
|
EX-G
|
EX-GS
|
EX-H
|
EX-HS
|
J
|
JX-G
|
JX-GS
|
JX-H
|
JX-HS
|
T
|
TX-G
|
TX-GS
|
TX-H
|
TX-HS
|
ASTM | ANSI | IEC | DIN | BS | NF | JIS | GOST |
(American Society for Testing and Materials) E 230 | (American National Standard Institute) MC 96.1 | (European Standard by the International Electrotechnical Commission 584)-1/2/3 | (Deutsche Industrie Normen) EN 60584 -1/2 | (British Standards) 4937.1041, EN 60584 - 1/2 | (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 | (Japanese Industrial Standards) C 1602 - C 1610 | (Unification of the Russian Specifications) 3044 |
Working Temperature Range
Diameter/mm | Long time Working temperature /ºC | Short period Working temperature /ºC |
0.3 | 700 | 800 |
0.5 | 800 | 900 |
0.8,1.0 | 900 | 1000 |
1.2,1.6 | 1000 | 1100 |
2.0,2.5 | 1100 | 1200 |
3.2 | 1200 | 1300 |
|
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2016
Total Annual:
1000000-120000000+
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Changzhou DLX Alloy Co., Ltd. was established in 2016 and has passed ISO9001 international quality management system certification and SGS certification. Our factory is becoming a high-tech enterprise specializing in the research and production of special alloy materials. The production process incl... Changzhou DLX Alloy Co., Ltd. was established in 2016 and has passed ISO9001 international quality management system certification and SGS certification. Our factory is becoming a high-tech enterprise specializing in the research and production of special alloy materials. The production process incl...