Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 500 Piece/Pieces per week |
Delivery Time | To be negotiated |
Packaging Details | Factory high quality packing carton or wooden case |
product name | XGW-12 European style inflatable cabinet cable branch box |
Protection level | IP33 IK10 |
Material | customized |
Application | Power Transmission |
Loop resistance | ≤100 |
Rated current | 50Hz |
Rated voltage | 12kV |
Features | Fully insulated and fully sealed |
structure type | Fixed |
Rated bus current | 630(A) |
Brand Name | Baikong |
Model Number | XGW-12 |
Certification | ISO9001,3C |
Place of Origin | Sichuan,China |
View Detail Information
Explore similar products
IP33 IK10 High Voltage Cable Branch Cabinet Ring Net Inflatable Medium Voltage
50Hz 12kV ISO9001 Inflatable Cable Branch Cabinet Fully Sealed Medium Voltage
630A Cable Branch Medium Voltage Products European Style 35kV
10KV Cable Branch Medium Voltage Products For Power Transmission 50Hz 45kV/Min
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 500 Piece/Pieces per week |
Delivery Time | To be negotiated | Packaging Details | Factory high quality packing carton or wooden case |
product name | XGW-12 European style inflatable cabinet cable branch box | Protection level | IP33 IK10 |
Material | customized | Application | Power Transmission |
Loop resistance | ≤100 | Rated current | 50Hz |
Rated voltage | 12kV | Features | Fully insulated and fully sealed |
structure type | Fixed | Rated bus current | 630(A) |
Brand Name | Baikong | Model Number | XGW-12 |
Certification | ISO9001,3C | Place of Origin | Sichuan,China |
High Light | European style cable branch box ,Cable Branch Box 630A ,Fixed Structure AC Switchgear |
630A 12kV 50Hz Cable Junction Box Cable Branch Box Fixed Structure Medium Voltage Products
Overview
XGW-12 box-type switching station (outdoor ring net box) is equipped with ZBF series box-type gas-insulated metal-enclosed switchgear. It is suitable for three-phase AC 50Hz, rated voltage 12kV power system, used for splitting and combining load current and overload current, and used for electric energy distribution, control and protection in the power system. As a ring network and terminal power supply equipment, it is widely used in the construction and transformation of urban and rural networks.
This box-type opening and closing has the characteristics of small size, compact structure, convenient combination, beautiful appearance, safe and reliable operation, convenient maintenance, and small on-site installation workload.
The main technical parameters
Serial number | First name | Single bit | Refer to the number |
1 | Rated voltage | kV | 12 |
2 | Rated frequency | Hz | 50 |
3 | Rated current | A | 630 |
4 | Rated short-time power frequency withstand voltage (1min) (phase to phase, phase to ground) | kV | 42 |
5 | Rated short-time power frequency withstand voltage (1min) (isolation fracture) | kV | 48 |
6 | Rated short-time power frequency withstand voltage (1min) (auxiliary and control circuit) | kV | 2 |
7 | Rated lightning impulse withstand voltage (peak value) (phase to phase, phase to ground) | kV | 75 |
8 | Rated lightning impulse withstand voltage (peak value) (isolated fracture) | kV | 85 |
9 | Rated short-time withstand current (main circuit) | kA/s | 20/4 |
10 | Rated short-time withstand current (ground loop) | kA/s | 17.4/2 |
11 | Rated peak withstand current (main circuit) | kA | 50 |
12 | Rated peak withstand current (ground loop) | kA | 43.5 |
13 | Main circuit resistance (two adjacent units) | μΩ | ≤300 |
14 | Protection level | IP33 IK10 | |
15 | Internal arc test | Cable room 20 kA/0.5 s | |
Switch room 20 kA/0.5 s |
Use environment
lThe ambient air temperature does not exceed 40°C, and the average value measured within 24 hours does not exceed 35°C.
The minimum ambient air temperature is -15°C.
Maximum wind speed: 35m/s.
The altitude does not exceed 1000m.
The surrounding air is not significantly polluted by dust, smoke, corrosive and flammable gas, vapor or salt spray.
Humidity
Relative humidity: the daily average does not exceed 95%, and the monthly average does not exceed 90%.
Water vapor pressure: the daily average value does not exceed 2.2kPa, and the monthly average value does not exceed 1.8kPa.
Vibration or ground movement from outside the switchgear and control equipment can be ignored.
Compliance with standards
GB311.1-2012 Insulation coordination of high-voltage power transmission and transformation equipment
GB1984-2003 High voltage AC circuit breaker
GB3804-2004 3.6kV~40.5kV high voltage AC load switch
GB3906-2006 3.6kV~40.5kV AC metal-enclosed switchgear and control equipment
GB/T11022-2011 Common technical requirements for high-voltage switchgear and control equipment
GB16926-2009 AC high voltage load switch-fuse combination electrical appliance
GB1985-2004 High-voltage AC isolation switch and grounding switch
DL/T404-2000 3.6kV~40.5kV AC metal-enclosed switchgear and control equipment
DL/T593-2006 Common technical requirements for high-voltage switchgear and control equipment
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler
Year Established:
2020
Total Annual:
1000000-100000000
Employee Number:
30~100
Ecer Certification:
Active Member
Sichuan Baikong Electric Technology Co., Ltd. is located in Pengzhou, Chengdu, Sichuan Province—the hometown of the beautiful panda, the land of abundance, with a registered capital of 106800000 yuan. It is a member of the Standing Committee of the Foreign Trade Commission of the S... Sichuan Baikong Electric Technology Co., Ltd. is located in Pengzhou, Chengdu, Sichuan Province—the hometown of the beautiful panda, the land of abundance, with a registered capital of 106800000 yuan. It is a member of the Standing Committee of the Foreign Trade Commission of the S...
Get in touch with us