China factories

China factory - Sichuan Baikong Electric Technology Co., Ltd.

Sichuan Baikong Electric Technology Co., Ltd.

  • China ,Sichuan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 10Kv Automatic High Voltage Vacuum Contactor Group Switching
China 10Kv Automatic High Voltage Vacuum Contactor Group Switching

  1. China 10Kv Automatic High Voltage Vacuum Contactor Group Switching
  2. China 10Kv Automatic High Voltage Vacuum Contactor Group Switching

10Kv Automatic High Voltage Vacuum Contactor Group Switching

  1. MOQ: 1sets
  2. Price: $1000-$100000
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 500 Piece/Pieces per week
Delivery Time To be negotiated
Packaging Details Factory high quality packing carton or wooden case
product name High-voltage vacuum contactor automatic group switching capacitor cabinet
model HZS-BKS
Material customized
Power frequency withstand voltage Once/42Kv/1 min twice/2Kv/1min
Rated voltage level 3kv、6Kv、10Kv(50Hz)
Color customized
Size customized
Reactance rate 5%,6%,12%
Supply Capacity 500 Piece/Pieces per week
Features Long life and low loss
Brand Name Baikong
Model Number HZS-BKS
Certification ISO9001,3C
Place of Origin Sichuan,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Supply Ability 500 Piece/Pieces per week
Delivery Time To be negotiated Packaging Details Factory high quality packing carton or wooden case
product name High-voltage vacuum contactor automatic group switching capacitor cabinet model HZS-BKS
Material customized Power frequency withstand voltage Once/42Kv/1 min twice/2Kv/1min
Rated voltage level 3kv、6Kv、10Kv(50Hz) Color customized
Size customized Reactance rate 5%,6%,12%
Supply Capacity 500 Piece/Pieces per week Features Long life and low loss
Brand Name Baikong Model Number HZS-BKS
Certification ISO9001,3C Place of Origin Sichuan,China
High Light automatic High voltage vacuum contactorHigh voltage vacuum contactor group10Kv vacuum capacitor switch

High-voltage vacuum contactor automatic group switching capacitor cabinet

 

 

The main technical parameters

 

Altitude ≤ 2000m (please specify when ordering more than 2000m)
Relative humidity ≤ 95% (at 25℃)
Use environment There is no obvious powdery corrosive combustible gas around, no violent vibration, and the vertical tilt angle does not exceed 5 degrees.
Rated voltage 3kv,6Kv,10Kv (50Hz)
Compensation capacity The compensation capacity of a single capacitor cabinet does not exceed 2000kvar
Reactance rate 5%,6%,12%
Capacitor wiring Three-phase star type, neutral point is not grounded
Switching method Tracking load reactive power changes, fully automatic grouping and grading switching capacitors
Power frequency withstand voltage Once/42Kv/1 min twice/2Kv/ 1min
Ambient temperature -25℃----+45℃

 

 

Overview

 

HZS-BKS 10kV high-voltage reactive power automatic compensation device, according to the reactive load change of the distribution transformer, automatically switches the capacitor bank connected in parallel to the 3-20kV bus of the distribution transformer step by step to compensate the corresponding capacitive reactive power; It has the advantages of flexible site selection, easy installation, high degree of intelligence, high operating efficiency and long service life. It is suitable for real estate, chemical industry, metallurgical manufacturing, transportation, coal mining, and substation applications to improve power quality, reduce loss and energy saving, and improve the economic benefits of power supply enterprises.

HZS-BKS high-voltage grouping automatic reactive power compensation device automatically switches on and off the capacitor bank according to the voltage and reactive power of the power supply bus, and tracks the change of load for reactive power compensation, thereby providing power factor, improving power supply quality, and reducing power loss. Installed on the outlet bus side of a 35kv or 110kv substation, or installed in a 6, 10kv switchgear, and often installed in front of the control cabinet of a high-voltage motor in a working condition enterprise for on-site compensation.

This device is equipped with reactive power automatic compensation, automatic tracking of reactive power load changes, switching capacitor banks, improving power factor, and improving power quality; suppressing harmonic function, can be equipped with series reactor according to the harmonic situation given on-site to form an LC Circuit, suppression of harmonics; perfect capacitor bank protection, with over-voltage protection, under-voltage protection, over-current protection, zero-sequence voltage protection, capacitor branch unbalanced voltage protection

 

 

10kv reactive power compensation device structure

 

Reactive power compensation controller (PFC) and microcomputer capacitor protector (CXB), current transformer (CT), drop-out fuse (FU), lightning arrester (FV), discharge coil (TV), high-voltage AC vacuum contactor (KM) ), reactor (L), capacitor protection high-voltage fuse (according to capacitor bank configuration) and power capacitor bank (C) (according to user distribution load) and other parts.

 

 

Product one-time system diagram

 

 

working principle

 

The 10kv reactive power compensation device collects the A and C phase voltage signals by the system voltage transformer (PT), and the system current transformer (CT) collects the B phase current signal and transmits it to the HZS type reactive power compensation controller. After the controller sampling circuit, the analog signals of voltage and current are obtained, and then through A/D conversion, the digital quantities of voltage, current, etc. are obtained, and then the voltage, current, active power, and no Power, power factor, harmonic percentage and other parameters, and the system set point stored in the fixed memory (users can choose different control modes according to the above parameters. For example: according to reactive power + voltage, voltage, current, power factor Etc.) for comparison, the system decides under what circumstances to operate the capacitor bank, and performs the opening and closing of the capacitor bank through the high-voltage AC vacuum contactor, so as to achieve the purpose of automatically switching the capacitor bank and compensating the reactive power of the circuit. The supply and demand of reactive power on the network are automatically balanced on-site, which plays an important role in reducing line loss, improving power factor and system transmission capacity, and improving the quality of power supply in the distribution network.

 

 

Product advantages

 

01Strict component selection-focus on quality

Strict selection of component suppliers, must have professional production sites, office environment, and supplied products must have inspection certificates from domestic professional institutions, and have more than 8 years of production to be selected into the company's supplier list.

02Clean working environment-focus on the brand

Standardized production plant area, automated production process, adopts modern automatic control and automatic self-inspection production line, no crossover, no failure; all-round testing equipment and testing process, just to create high-quality products!

03Data monitoring-to create an electric safety steward

The self-developed data collection and monitoring system covers regional communications across the country, and provides 24-hour uninterrupted data collection. It has basic functions such as remote adjustment, remote control, telemetry, and remote signaling. It also has fault notification and compensation optimization, which is a real sense of safety. The smart housekeeper of electricity and comfortable use of electricity!

 

 

Conditions of Use

 

One: working environment conditions

A. Outdoor ambient air temperature: -35℃~+45℃

B. Relative humidity of ambient air: 20%~90% at 40℃;

C. Atmospheric pressure: 2000 meters above sea level and below.

Two: Surrounding environment requirements

A. Strong vibration and shock are not allowed;

B. No gases that corrode and damage insulation, conductive media, or dangerous media are allowed to exist, and no serious molds are allowed.

 

 

product model

 

Device model Compensation capacity (kvar) Number of groups Capacity of each group (kvar) Number of cabinets Cabinet size
Width * depth * height
HZS-BKS6-600/3-10 600 3 100+200+300 3 3000*1500*2650
HZS-BKS6-700/3-10 700 3 100+200+400 3 3000*1500*2650
HZS-BKS6-800/3-10 800 3 100+250+450 3 3000*1500*2650
HZS-BKS6-900/3-10 900 3 150+300+450 3 3000*1500*2650
HZS-BKS6-1000/3-10 1000 3 200+300+500 3 3000*1500*2650
HZS-BKS6-1100/3-10 1100 3 200+400+500 3 3000*1500*2650
HZS-BKS6-1200/3-10 1200 3 200+400+600 3 3000*1500*2650
HZS-BKS6-1300/3-10 1300 3 200+450+650 3 3000*1500*2650
HZS-BKS6-1400/3-10 1400 3 200+400+800 3 3000*1500*2650
HZS-BKS6-1500/3-10 1500 3 250+500+750 3 3000*1500*2650
HZS-BKS6-1600/3-10 1600 3 200+600+800 3 3000*1500*2650
HZS-BKS6-1700/3-10 1700 3 200+600+900 3 3000*1500*2650
HZS-BKS6-1800/3-10 1800 3 300+600+900 3 3000*1500*2650
HZS-BKS6-1900/4-10 1900 4 200+400+600+700 4 4000*1500*2650
HZS-BKS6-2000/4-10 2000 4 200+400+600+800 4 4000*1500*2650
HZS-BKS6-2100/3-10 2100 4 150+300+600+1050 4 4000*1500*2650
HZS-BKS6-2400/4-10 2400 4 200+400+800+1000 4 4000*1500*2650
HZS-BKS6-2700/4-10 2700 4 200+400+800+1300 4 4000*1500*2650
HZS-BKS6-3000/4-10 3000 4 200+400+800+1600 4 4000*1500*2650
HZS-BKS6-3600/5-10 3600 5 200+400+800+1000+1200 5 6000*1500*2650
HZS-BKS6-4200/5-10 4200 5 200+400+800+1200+1600 5 6000*1500*2650
HZS-BKS6-4800/5-10 4800 5 200+400+800+1600+1800 5 6000*1500*2650
HZS-BKS6-5400/5-10 5400 5 300+900+900+1500+1800 5 6000*1500*2650
HZS-BKS6-6000/5-10 6000 5 600+900+1500+1800+1800 5 6000*1500*2650
HZS-BKS6-6600/5-10 6600 5 900+1200+1200+1500+1800 5 6000*1500*2650
HZS-BKS6-7200/5-10 7200 5 900+1200+1500+1800+1800 5 6000*1500*2650
HZS-BKS6-7800/5-10 7800 5 1000+1200+1600+2000+2000 5 6000*1500*2650
HZS-BKS6-8400/5-10 8400 5 1000+1600+1800+2000+2000 5 6000*1500*2650
HZS-BKS6-9000/5-10 9000 5 1000+2000+2000+2000+2000 5 6000*1500*2650

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Year Established:

    2020

  • Total Annual:

    1000000-100000000

  • Employee Number:

    30~100

  • Ecer Certification:

    Active Member

Sichuan Baikong Electric Technology Co., Ltd. is located in Pengzhou, Chengdu, Sichuan Province—the hometown of the beautiful panda, the land of abundance, with a registered capital of 106800000 yuan. It is a member of the Standing Committee of the Foreign Trade Commission of the S... Sichuan Baikong Electric Technology Co., Ltd. is located in Pengzhou, Chengdu, Sichuan Province—the hometown of the beautiful panda, the land of abundance, with a registered capital of 106800000 yuan. It is a member of the Standing Committee of the Foreign Trade Commission of the S...

+ Read More

Get in touch with us

  • Reach Us
  • Sichuan Baikong Electric Technology Co., Ltd.
  • D5-4 Workshop 389 3rd Section, East third Ring Road, Industrial Development Zone ,Pengzhou City, Sichuan Province
  • https://www.distribution-cabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement