125A MCB Circuit Breaker Residual Current

  1. MOQ: 10 Pieces(MOQ)
  2. Price: $13.07-$30.67/ Piece
  3. Get Latest Price
Payment Terms T/T,, L/C, Western Union
Supply Ability 50000 Pieces/per Week
Delivery Time 5...15Days OR To be negotiated
Packaging Details wooden box/standard exporting carton
Product name 125A Residual Current Operated Circuit Breaker
Poles Number 1P,1P+N,2P,3P,3P+N,4P
BCD Curve C
Material Plastic, Metal
Color White, customized
Circuit capacity 6000A
Rated Frequency 50Hz
Rated current 63A...125A
Rated voltage 230V/400V
Warranty 1year
Brand Name Baikong
Model Number DZ47LE-125
Certification CCC、CE
Place of Origin Sichuan,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T,, L/C, Western Union Supply Ability 50000 Pieces/per Week
Delivery Time 5...15Days OR To be negotiated Packaging Details wooden box/standard exporting carton
Product name 125A Residual Current Operated Circuit Breaker Poles Number 1P,1P+N,2P,3P,3P+N,4P
BCD Curve C Material Plastic, Metal
Color White, customized Circuit capacity 6000A
Rated Frequency 50Hz Rated current 63A...125A
Rated voltage 230V/400V Warranty 1year
Brand Name Baikong Model Number DZ47LE-125
Certification CCC、CE Place of Origin Sichuan,China
High Light 125A MCB Circuit BreakerMCB Circuit Breaker Residual Current125A Residual Current Circuit Breaker

125A Residual Current Operated Circuit Breaker RCB MCB Performance Heat Resistant

 

 

 

Application

The DZ47LE residual current operated circuit breaker is applicable to the circuit with an alternating current of 50Hz, rated-voltage single pole and two lines/two poles 230V, three poles/three poles and four lines/four poles 400V, and a rated current 63~125A; when the human body gets an electric shock or the networkleakcurrent exceeds the specified value, the residual current operated circuit breaker can rapidly cut off the power supply in trouble within a very short time for the safety of the human body and the powered equipment. With the function of overload and short circuit protection, the residual current operated circuit breaker can be used to protect the circuit or motor from being damaged by overload and short circuit, and can also be used for not–frequent operational transformation in the circuit under normal condition.The product meets the standards of GB14048.2 and IEC60947-2.

 

 

 

Model

 

Main Technical Data

Main specifications

Poles: 1P + N, 2P, 3P, 3P + N, 4P;
Short circuit tripping characteristics: (8 ~ 12) In.

 

Technical parameters

Rated voltage Ue (V): 1P+N, 2P: 230;
3P, 3P+N, 4P: 400;
Rated current In (A): 63,80,100,125.
Frame rated current Inm (A): 125;
Rated residual operating current I△n (A): 0.03,0.1,0.3;
Rated residual non-operating current I△no (A): 0.5I△n;
Rated short-circuit breaking capacity Icu (A): 6000;
Rated residual making and breaking capacity I△ m (A): 2000;
Residual current breaking time ( Table 1).

 

IΔn(mA)

The maximum breaking time(s) and not the minimum driving time (s)

lΔn

2IΔn

5IΔn

10IΔn

≥30

0.1

0.06

0.04

0.04

 

For the over current protection characteristics ( Table 2).

 

 

Initial state

Test current

Time imit

Expected result

Remarks

ln=63A

ln>63A

Cold state

1.05ln

t≤1h

t≤2h

No tripping

 

Right after test number a

1.30ln

t<1h

t<2h

Tripping

The current is rising within 5s

Cold state

8ln

t≤0.2s

No tripping

The power supply is tumed on by closing the auxiliary switch

Cold state

12ln

t<0.2s

Tripping

 

Mechanical/Electrical Life
a. Electrical life: no less than 1,500 times
b. Mechanical life: no less than 8,500 times
Insulation shock-resistance voltage performance: Uimp(V):4000;
The residual current operated circuit breaker has the capability of withstanding
the impact of the surge current with a peak current of 200A without causing misoperation;

 

Characteristic curve( Fig.1)

 

External And Installation Size

 

Normal operating conditions

Ambient air temperature: -5°C~+40°C, the mean value is no greater than +35°C within 24 hours .

Altitude: not higher than 2000m for the installation site.

Installation category: III grade.

Pollution degree: 3.

Installation: TH35-7.5 DIN rail

Installation conditions: external magnetic field in any direction installation site should not exceed five times the Earth's magnetic field; residual current operated circuit breakers should be installed vertically, the handle for the power-up position; installation should be no significant impact and vibration.

 

 

 

 

Circuit breakers perform 3 key functions: protection, switching, and monitoring. Circuit breakers are designed to “break” (discontinue) the flow of electricity to protect people and equipment when current reaches an unsafe level due to overload, short circuit, or other electrical faults. We are your one source solution for all your circuit breaker and equipment needs.

 

 

Normally, we will provide the most suitable shipment method for you. If the quantity is few, the goods will be sent by express when the payment is clear. Also, we can transport the goods by air or by sea, just according to your demand

 

 

 

Sichuan Baikong Electrical Technology Co.,Ltd has perfect testing equipment and strict testing standards, perfect management and operation and quality assurance system. The company adheres to the enterprise purpose of synchronizing with the world and win-win with customers, adhering to scientific management, loyal to design, pioneering and innovation, and tree corporate image Business philosophy, and fully understand customer needs, do the customers think, with customers to create, win-win best control electrical staff continuously forge ahead The spirit of pragmatic innovation, serving the power construction at home and abroad to compose the new chapter The control electrical products successively in the national key projects and large enterprises are widely used, and to get the customer the consistent approval .

Sichuan Baikong Electric Technology Co., Ltd sincerely look forward to the presence and cooperation of old and new customers and win-win new future together.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Year Established:

    2020

  • Total Annual:

    1000000-100000000

  • Employee Number:

    30~100

  • Ecer Certification:

    Active Member

Sichuan Baikong Electric Technology Co., Ltd. is located in Pengzhou, Chengdu, Sichuan Province—the hometown of the beautiful panda, the land of abundance, with a registered capital of 106800000 yuan. It is a member of the Standing Committee of the Foreign Trade Commission of the S... Sichuan Baikong Electric Technology Co., Ltd. is located in Pengzhou, Chengdu, Sichuan Province—the hometown of the beautiful panda, the land of abundance, with a registered capital of 106800000 yuan. It is a member of the Standing Committee of the Foreign Trade Commission of the S...

+ Read More

Get in touch with us

  • Reach Us
  • Sichuan Baikong Electric Technology Co., Ltd.
  • D5-4 Workshop 389 3rd Section, East third Ring Road, Industrial Development Zone ,Pengzhou City, Sichuan Province
  • https://www.distribution-cabinet.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement