Packaging Details | Carton |
Interface type | Analog Input |
Product name | Analog Input Module |
Input signal | 4 to 20 mA |
Data update period | 10 ms |
HART communication | Available |
Number of input channels | 16, isolated |
Maximum current consumption | 230 mA (5 V DC), 540 mA (24 V DC) |
Color | Grey |
Brand Name | Yokogawa |
Model Number | AAI143-H50 |
Certification | CE |
Place of Origin | Indonesia |
View Detail Information
Explore similar products
SSVR Solid State Voltage Regulator 4-20mA Single Phase Programmable Automation
E-T-A Double Pole Electronic Circuit Breaker DC 24V Ess22-t
AC 90-260V PLC Programmable Controller NPN Output 24 Points
SM331 Siemens PLC Module 6ES7331-7KF02-0AB0 Potential Isolation
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 500 |
Delivery Time | 5-8 work days | Packaging Details | Carton |
Interface type | Analog Input | Product name | Analog Input Module |
Input signal | 4 to 20 mA | Data update period | 10 ms |
HART communication | Available | Number of input channels | 16, isolated |
Maximum current consumption | 230 mA (5 V DC), 540 mA (24 V DC) | Color | Grey |
Brand Name | Yokogawa | Model Number | AAI143-H50 |
Certification | CE | Place of Origin | Indonesia |
High Light | AAI143-S00 Analog Input Module ,Analog Input Programmable Logic Controller ,20mA Analog Input Module |
This GS covers the hardware specifications of the Analog I/O Modules (for FIO) that can be installed in the Node Unit for ESB Bus (Local Node) (ANB10S, ANB10D), the Node Unit for ER Bus (Remote Node) (ANR10S, ANR10D) and Compact Field Control Unit (for FIO) (AFF50S, AFF50D, AFV10S, AFV10D).
STANDARD SPECIFICATIONS
Current/Voltage Input Modules (Non-Isolated)
These modules mainly receive 4 to 20 mA DC or 1 to 5 V DC standardized signal from 2-wire/4-wire transmitters. They can be used in dual redundant configuration.
item | value |
Place of Origin | Indonesia |
Brand Name | Yokogawa |
Model Number | AAI143- |
Interface type | Analog Input |
Product name | Analog Input Module |
Warranty | 12 Months |
Condition | 100% Original |
Number of input channels | 16, isolated |
Input signal | 4 to 20 mA |
Weight | 0.5 kg |
HART communication | Available |
Data update period | 10 ms |
Maximum current consumption | 230 mA (5 V DC), 540 mA (24 V DC) |
Color | Grey |
Current Input Modules (Isolated)
AAI143 provides 16 inputs of 4 to 20 mA signal. It can be used in dual-redundant configuration.
Items | Specifications |
Model | AAI143 (*1) |
Number of input channels | 16, isolated |
Input signal | 4 to 20 mA |
Allowable input current | 24 mA |
Input resistance | Power ON 270 Ω (20 mA) to 350 Ω (4 mA) (*2) |
Power OFF 500 kΩ or larger | |
Accuracy | ±16 μA |
Data update period | 10 ms |
Transmitter power supply | 19.0 V or higher (at 20 mA) 25.5 V or less (at 0 mA) (output current limit: 25 mA) (*5) |
Setting of 2-wire or 4-wire transmitter | For each channel by setting pin |
Drift due to ambient temperature change | ±16 μA/10 C |
Maximum current consumption | 230 mA (5 V DC), 540 mA (24 V DC) |
Weight | 0.3 kg |
External communication | Pressure clamp terminal, MIL connector cable, dedicated cable (KS1) |
HART communication (*3) | Available |
*1: A Zener barrier is not allowed to be connected with this module. Use an isolation barrier when the module is used in
intrinsically safe application.
*2: The module input resistance viewed from the terminals depends on the current strength as calculated as below:
250 Ω +
current value
voltage drop in the input protection circuit
F04E.ai
*3: When this module is installed to a ER bus node unit with HART function, the EB401 firmware must be rev. 2 or later.
*4: When the dedicated cable is used, the withstanding voltage is 500 V AC (between the input signal and the system). When
the ML connector cable is used, the withstanding voltage depends on the electrical specifications of the cable.
*5: This voltage is generated between the connecting terminals for 2-wire transmitters for this module. When calculating the
minimum operating voltage for transmitters, consider to allow margins for voltage drop in external wiring.
Yokogawa Analog Input Module AAI143-H00
EXTERNAL DIMENSIONS of AAI143-H00
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
30~60
Ecer Certification:
Verified Supplier
Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential... Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential...
Get in touch with us
Leave a Message, we will call you back quickly!