Payment Terms | L/C, T/T |
Supply Ability | 50 Sets per month |
Delivery Time | 20 working days |
Packaging Details | Standard export packing |
Product name | 1000KVA Cummins Genset |
Color | Green |
Cylinder No. | 12V |
Alternator Type | Brushless |
Cooling Type | Water cooled |
Engine brand | Cummins |
Alternator brand | Engga |
Control Panel | Smartgen |
Brand Name | SHX |
Model Number | SCE1000 |
Certification | ISO9001:2015, CE, TUV, BV |
Place of Origin | Foshan, China |
View Detail Information
Explore similar products
Open Skid 1500RPM Cummins Backup Generator 3 Phase 280KW / 350KVA
Electric Cummins Diesel Generator Heavy Duty 50KVA Smartgen Controller
800KW / 1000KVA 3 Phase Cummins Diesel Generator 50Hz 400/230V
Water Cooled Cummins Diesel Genset 600KW / 750KVA With EFC Speed Governor
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 50 Sets per month |
Delivery Time | 20 working days | Packaging Details | Standard export packing |
Product name | 1000KVA Cummins Genset | Color | Green |
Cylinder No. | 12V | Alternator Type | Brushless |
Cooling Type | Water cooled | Engine brand | Cummins |
Alternator brand | Engga | Control Panel | Smartgen |
Brand Name | SHX | Model Number | SCE1000 |
Certification | ISO9001:2015, CE, TUV, BV | Place of Origin | Foshan, China |
High Light | cummins backup generator ,cummins diesel engine generators |
1000KVA Water Cooled Diesel Generator Cummins Power KTA38-G5 1500RPM
Genset Data: 400/230V, 50Hz, 3 Phase 4 Pole, 1500RPM, Power Factor 0.8.
Product Description:
1. Prime power 1000KVA, standby power 1100KVA.
2. Powered by Cummins engine.
3. Original Engga alternator.
4. Delixi air breaker.
5. Electric start with batteries.
6. Smartgen controller.
7. ATS is for option.
Genset Specifications:
Genset Model | SCE1000 |
Prime Power | 800KW/1000KVA |
Rated Voltage | 400/230V |
Frequency | 50Hz |
Power Factor | 0.8(lagging) |
Dimension (L×W×H) (mm) | 4200×1800×2300 |
Genset weight (kg) | 7900 |
Engine Specifications:
Diesel Engine | |
Brand | CCEC Cummins |
Model | KTA38-G5 |
Number of Cylinders | 12 |
Rotating Speed | 1500RPM |
Cylinder Arrangement | 60º Vee form |
Cycle | Four stroke |
Aspiration | Turbocharged after water-cooled |
Bore×Stroke(mm) | 159 x 159 |
Displacement(L) | 37.8 |
Compression Ratio | 15.5:1 |
Speed Governor | EFC speed governor |
Cooling System | Water-cooled |
Speed Stability (%) | ≤5% |
Total Lubrication System Capacity (L) | 129 |
Fuel Consumption at 100% Load | 196g/kwh |
Starting Method | DC 24V Electrical starting |
Alternator Specifications:
Alternator | |
Brand | Engga |
Model | EG400-800N |
Number of Phase | 3 |
Connecting Type | 3 Phase and 4 Wires |
Number of Bearing | 1 |
Protection Grade | IP21 |
Altitude | ≤1000m |
Exciter Type | Brushless ,Self-excited, AVR automatic voltage regulation |
Insulation Class | H |
Telephone Influence Factor (TIF) | ≤50 |
THF | ≤2% |
Voltage Regulation, Steady State | ≤±1% |
Transient State Voltage | ≤-15%~+20% |
Introduction of Diesel Generator:
A Diesel Generator (DG) is a combination of diesel engine with electrical generator (often called an alternator) to generate electricity. DG sets are used in places that have no connection to power grid, and as emergency power-supply if the grid fails. In other words, DG sets remain the number one choice for standby and emergency power systems. DG sets are selected based on the electrical load they are intended to supply.
SCOPE OF SUPPLY
1. DIESEL ENGINE
1.1 Engine which includes wet type cylinder, direct injection combustion chamber, exhaust turbocharger, water cooling, electronic governor, etc.
1.2 Fuel system, which includes, fuel pump, strainers or filters, etc.
1.3 Air intake and exhaust system, which includes air filter, exhaust silencer, bellow, all intake and exhaust piping, cablings, instruments, valves and settings, etc.
1.4 Cooling system, which includes radiator with water level alarm and indicator, thermostatic switch, thermostatic heater, engine shaft mounted fan, all interconnecting piping, cablings, instruments, valves and settings, etc.
1.5 Lubricating system includes pumps, oil sumps, oil strainers and filters, all interconnecting piping, instruments, valves and settings, etc.
1.6 Starting system, which includes 2 sets of batteries, a set of AC charger, and interconnecting piping, cablings, instrument, valves and settings, etc.
2. AC SYNCHRONOUS GENERATOR
2.1 Generator, which includes exciter, rectifier, AVR, shaft mounted fan if required.
2.2 All interconnecting piping, cablings, instruments, valves and settings, etc.
3. COUPLINGS AND GUARD
3.1 Coupling
3.2 Coupling Guard
4. CONTROL PANEL
4.1 Local automatic control panel
5. BASEPLATE
5.1 Common base plate
6. DOCUMENTS
6.1 Generator Set Installation Manual
6.2 Generator Set Operation and Maintenance Manual
6.3 Generator Set Control Panel Manual
6.4 Engine Manual and Quality File
6.5 Alternator Manual and Quality File
6.6 Factory Acceptant Test Report
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2000
Total Annual:
1500-2000
Employee Number:
50~100
Ecer Certification:
Active Member
GUANGDONG SUNKINGS ELECTRIC CO., LTD is one of the leading generator sets manufacture and supplier in southern China since 1993. We make Diesel Generator Sets /Biogas Generator Sets covering 20KW to 2400KW (25KVA to 3000KVA), and offer fully power solutions for agricultural and industrial purpos... GUANGDONG SUNKINGS ELECTRIC CO., LTD is one of the leading generator sets manufacture and supplier in southern China since 1993. We make Diesel Generator Sets /Biogas Generator Sets covering 20KW to 2400KW (25KVA to 3000KVA), and offer fully power solutions for agricultural and industrial purpos...