China factories

China factory - Shenzhen Creatall Electronics Co., Ltd.

Shenzhen Creatall Electronics Co., Ltd.

  • China
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China DC4-30V Voltage And Current Meter 10A 50A 100A Power Car Motorcycle
China DC4-30V Voltage And Current Meter 10A 50A 100A Power Car Motorcycle

  1. China DC4-30V Voltage And Current Meter 10A 50A 100A Power Car Motorcycle
  2. China DC4-30V Voltage And Current Meter 10A 50A 100A Power Car Motorcycle
  3. China DC4-30V Voltage And Current Meter 10A 50A 100A Power Car Motorcycle

DC4-30V Voltage And Current Meter 10A 50A 100A Power Car Motorcycle

  1. MOQ: 10pcs
  2. Price: Negotiable
  3. Get Latest Price
Display Type Digital Only
Measuring Range 0~100V
Dimensions 4.8*3*2.3cm
Ship way by air or by sea
Manufacturer Yes
Delivery time Ship out within 24hours
Delivery Time 5-8 work days
Place of Origin Guangdong, China
Brand Name Original Brand

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Display Type Digital Only Measuring Range 0~100V
Dimensions 4.8*3*2.3cm Ship way by air or by sea
Manufacturer Yes Delivery time Ship out within 24hours
Delivery Time 5-8 work days Place of Origin Guangdong, China
Brand Name Original Brand
High Light 30V Voltage And Current MeterDC4v Voltage And Current MeterVoltage Current Meter 100A

DC4-30V LED Digital Voltmeter Ammeter 10A 50A 100A Power Car Motorcycle Voltage Current Meter Volt Detector Tester

Product Description:

M430 is a voltage, current and power measuring instrument. It can only measure and display the voltage, current and power of the circuit under test. The displayed value can be fine-tuned through an adjustable resistance. The actual voltage and current of the loop has no effect.

Do not use high voltage above 30V when using, otherwise it will cause overvoltage damage to the product.

The 10A range product comes with a shunt resistor, and there will be a short circuit at the test end of the direct current measurement. As long as the meter is connected in series with the load according to the wiring diagram, it can be used normally.

 

Operating Voltage:
The working voltage of the instrument is DC 4~30V, 5~12V is recommended
The thin red line is the positive pole of the working power supply, and the thin black line is the negative pole of the working power supply, which belongs to the common ground with the thick black line.
When using, the limit voltage connected to the thin red and black wires cannot exceed 30V, and 12V power supply is recommended

Measuring range:
The voltage measurement range is 0~100V, the display mode below 10V is 0.00V, the voltage starts at 0.2V, and the error range is ±1V.
The current measurement range is 0~10A, the current starts at 0.03A, and the error is ±0.1A

Voltage display fine-tuning
It is the display fine adjustment, not the major adjustment, the adjustment is the display voltage, but the actual voltage cannot be adjusted!
Find a flat-blade screwdriver and twist the V-ADJ round adjustable resistor to fine-tune the voltage

Current display fine-tuning
It is the display fine adjustment, not the major adjustment, the adjustment is the display current, but the actual current cannot be adjusted!
Find a flat-blade screwdriver and twist the A-ADJ round adjustable resistor to fine-tune the current

 

Standard wire:
XH-2.54-3P red, black and yellow wire (thin wire total length: 155mm)
Thin red line: positive pole of the working power supply, cannot connect to a power supply above 30V
Thin black wire: the negative pole of the working power supply, and the thick black wire on the construction site, do not need to be connected when sharing the power supply
Thin yellow line: voltage test line, connected to the positive pole of the test circuit power supply
VH-3.96-2P red and black wire (thick wire total length: 165mm) current test wire
Thick red wire: the positive pole of the current test, which is connected to the negative pole of the load.
Thick black wire: current test negative, connect to power negative, connect first and then disconnect when disconnected

No-load current does not return to zero processing method:
For zero-load zeroing, you need to prepare a pointed tweezers. Do not energize the load circuit. Power off the fine red and black. Insert the tweezers into the two round holes next to the I-ADJ-Z, power on the fine red and black, wait for 5 seconds, and remove the tweezers. , so it is forced to zero, if not, repeat the operation several times.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company

  • Year Established:

    2004

  • Total Annual:

    2000000-7200000

  • Employee Number:

    150~200

  • Ecer Certification:

    Verified Supplier

Shenzhen Creatall Electronics Co.,Ltd was founded in 2004,is a leading manufacturer and supplier of various modules, specializing in power supply modules, amplifier audio modules,BMS battery protection modules, Bluetooth modules,PWM motor speed controller,Lcd led Inverter board,voltmeter and other r... Shenzhen Creatall Electronics Co.,Ltd was founded in 2004,is a leading manufacturer and supplier of various modules, specializing in power supply modules, amplifier audio modules,BMS battery protection modules, Bluetooth modules,PWM motor speed controller,Lcd led Inverter board,voltmeter and other r...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Creatall Electronics Co., Ltd.
  • Address:Floor 2nd.Bldg B. Xin Mao Industrial Zone,Xia Wei Industrial Area, Long Hua District, Shen Zhen City,Guang Dong Province. China
  • https://www.creatall.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!