China factories

China factory - Kronz (guangzhou) Electronics Co., Ltd.

Kronz (guangzhou) Electronics Co., Ltd.

  • China,Guangzhou
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China RFID Gateway Module EtherCat Industrial Communication 18-30V M12 Connector
China RFID Gateway Module EtherCat Industrial Communication 18-30V M12 Connector

  1. China RFID Gateway Module EtherCat Industrial Communication 18-30V M12 Connector
  2. China RFID Gateway Module EtherCat Industrial Communication 18-30V M12 Connector

RFID Gateway Module EtherCat Industrial Communication 18-30V M12 Connector

  1. MOQ: 5 pieces
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 10000 pieces per month
Delivery Time 5-8 working days
Packaging Details Paper box packing
Description RFID Gateway Module
Use Industrial communications
Output 18-30VDC
Operating Temperature -30℃~+70℃
Interface RS-485
Application Industrial Communication
Current consumption <80mA@24V
RFID Connector M12 5Pin A coded Female
Model Number KRG60-EC
Place of Origin Guangdong, China
Brand Name KRONZ
Certification CE

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 10000 pieces per month
Delivery Time 5-8 working days Packaging Details Paper box packing
Description RFID Gateway Module Use Industrial communications
Output 18-30VDC Operating Temperature -30℃~+70℃
Interface RS-485 Application Industrial Communication
Current consumption <80mA@24V RFID Connector M12 5Pin A coded Female
Model Number KRG60-EC Place of Origin Guangdong, China
Brand Name KRONZ Certification CE
High Light RFID Gateway ModuleRFID Gateway Module EtherCatIndustrial Communication RFID Module 30V

RFID Gateway Module EtherCat Industrial Communication 18-30V M12 Connector


1. Advantages:
1>. High protection level and strong corrosion resistance, can be used in harsh industrial environments
2>. Supports mainstream PLCs , provides mature PLC function blocks/routines, and supports industrial communications such as TCP/IP, Modbus TCP , PROFINET, EtherCat and Ethernet/IP
3>. High stability and reliability, 7*24h operation

Characteristics
Design
① Dual network ports, support cascading
② Supports 6 RFID ports
Area of application
Applications in harsh industrial environments require multiple RFID and need to be connected to the bus network.

 

2. Electrical interface

LK1/LK2 Ethernet interface using a 4Pin-M12-DCODED-Female connector, the pin assignment is shown below.

Connector Pin Assignment Description
1 TD+ Tranceive Data+
2 RD+ Receive Data+
3 TD- Tranceive Data-
4 RD- Receive Data-
 

Pi/Po Power supply interface using a 5Pin-M12-LCODED-Male/Female connector, the pin assignment is shown below.

Connector(Male) Pin Assignment Description
1 US (+24V) System power supply positive
2 GNDL (0V) Load power supply negative
3 GNDS (0V) System power supply negative
4 UL (+24V) Load power supply positive
5 PE Protective earth

 

Connector(Male) Pin Assignment Description
1 US (+24V) System power supply positive
2 GNDL (0V) Load power supply negative
3 GNDS (0V) System power supply negative
4 UL (+24V) Load power supply positive
5 PE Protective earth

 

Connector Pin Assignment Description
1 US (+24V) System power supply positive
2 A (RS485) RS485 A
3 GNDS (0V) System power supply negative
4 B (RS485) RS485 A
5 NC Not connected

 

4 LED Operating display
The operational statuses of the gateway module are displayed by the LEDs. The LED
can adopt the colors blue or red and the statuses off, on, flashing.
The operational statuses can be divided into three categories: system status, RFID
status, and bus status.
System status
NOTICE: SYS is the system status LED, US is the voltage status LED, and CS is the key chip status LED.
Name
Color
State
Description
 
 
SYS
 
 
Blue
Red
Off
The GM is power off.
Blue LED on
The GM has completed initialization and is operating normally.
Blue LED flashing
The GM is running at default settings.
Red LED on
The GM is in BOOT mode.
Red LED flashing
Software failure.
 
 
 
US
 
 
 
Blue
Red
Off
Undefined (not used).
Blue LED on
All RFID port voltages are normal.
Blue LED flashing
Undefined (not used).
Red LED on
There is an abnormal voltage on a single RFID port.
Red LED flashing
There are abnormal voltages on multiple RFID ports.
 
 
 
 
 
CS
 
 
 
Blue
Red
Off
Undefined (not used).
Blue LED on
The key chip is working normally.
Blue LED flashing
The key chip temperature is too high.
Red LED on
The key chip communication abnormality.
Red LED flashing
The key chip initialization abnormality.
 
RFID Status
NOTICE: RFID has 6 ports ( RF1~RF6 ), and the RFID status is indicated by two LEDs 0/1 . 0 is equivalent to RUN , the running status indicator ; 1 is equivalent to ERR, the error status indicator.
Name
Color
State
Description
 
0
(RUN)
 
 
Blue
Off
Not enabled.
On
Communication with the reader is normal.
Flashing
Tags exist in the recognition range.
 
1
(ERR)
 
 
Red
Off
No abnormality
On
The voltage is too low.
Flashing
Communication abnormality with the reader.
 
Bus status:EtherCAT
NOTICE: BS0 is equivalent to R UN, the running status indicator; BS1 is equivalent to ERR, the error status indicator.
Name
Color
State
Description
 
 
 
BS0
 
 
 
Blue
Off
INIT: The device is in INIT state.
Flashing (2.5Hz)
PRE-OPERATIONAL: The device is in PRE-OPERATIONAL state.
Single flash
SAFE-OPERATIONAL: The device is in SAFE-OPERATIONAL state.
On
OPERATIONAL: The device is in the OPERATIONAL state.
 
 
 
 
 
 
 
BS1
 
 
 
 
 
 
 
Red
Off
No error: The EtherCAT communication of the device is in working condition.
Flashing (2.5Hz)
Invalid configuration: General Configuration Error Possible reason: State change commanded by master is impossible due to register
or object settings.
Single flash
Local error: Slave device application has changed the EtherCAT state autonomously.Possible reason 1: A host watchdog timeout has occurred. Possible reason 2: Synchronization Error, device enters Safe Operational
automatically.
Double flash
Application watchdog timeout: An application watchdog timeout has occurred. Possible reason: Sync Manager Watchdog timeout.
 
 
LK1/2(0)
 
 
Blue
Off
The device has no link to the Ethernet.
On
Link: The device is linked to the Ethernet, but does not send/receive Ethernet frames.
Flashing
Activity: The device is linked to the Ethernet and sends/receives Ethernet frames.
LK1/2(1)
Blue
Off
Undefined(not used)
 

Technical Data


Electrical data
Supply voltage
18-30VDC
Current consumption
< 80mA@24V
Power protection
Overcurrent protection, reverse connection protection, surge protection, ESD protection, FFT protection
Power Connector
5Pin-M12-LCODED- Male (PI)
5Pin-M12-LCODED-female(PO)
Bus
EtherCAT
Communication
Dual network ports with integrated switching function, compliant with IEE802.3 standard, 10 / 100M adaptive
Bus Transmission distance
Cat 5e and above shielded twisted pair,<100m
Network Connector
4Pin-M12-DCODED-M12-Female
RFID port number
6
RFID communication interface
RS-485
RFID port Transmission distance
Shielded twisted pair, < 50m
RFID connector
5Pin-M12-ACODED-Female
Permitted ambient conditions
Operation temperature
-30℃~+70℃
Storage temperature
-40℃~+85℃
Degree of protection
IP67, according to EN 60529
Shock resistance
7M2, 500 m/s2, according to EN 60721-3-7
Vibration resistance
7M2, 200 m/s2, according to EN 60721-3-7
Mechanical specifications
Housing Material
Aluminum Alloy
Housing color
Black
Weight
About 400g
Dimensions
167.92x62.92x31.90mm
Type of mounting
4 X M6 screws,
the length of the screw should be ≥ 20 mm
Grounding
1 X M3 screws,
Grounding ring inner diameter greater than 3 mm, outer diameter should be less than 8 mm.
Standards, specifications, approvals
Proof of suitability
CE FCC RoHS WEEE

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2021

  • Total Annual:

    5000000-6000000

  • Employee Number:

    80~120

  • Ecer Certification:

    Verified Supplier

Kronz is a manufacturing enterprise located in Zengcheng District, Guangzhou City. We focus on providing customers with high-efficiency industrial automation solutions and related industrial products. After many years of innovation and development, Kronz has complete product processing equipment and... Kronz is a manufacturing enterprise located in Zengcheng District, Guangzhou City. We focus on providing customers with high-efficiency industrial automation solutions and related industrial products. After many years of innovation and development, Kronz has complete product processing equipment and...

+ Read More

Get in touch with us

  • Reach Us
  • Kronz (guangzhou) Electronics Co., Ltd.
  • 6th Floor, B602 Building, No.10, Rong Jing 2nd Road, Yu Shan Guo Ji, Yong Ning Street, Zeng Cheng District, Guangzhou, P.R.China
  • https://www.connector-industrial.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!