Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"PD Free Ac Resonant Test Set Partial Discharge Test Equipment No More Than 10pC","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/84\/c0\/063309222a1eff32cbcb575183f1-200x200-1\/pd_free_ac_resonant_test_set_partial_discharge_test_equipment_no_more_than_10pc.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"FKWJF Series","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Variable Frequency AC DC Hipot Test Equipment Fast Discharge High Accuracy","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/82\/48\/e56381f41b0590684b4a14d5371e-200x200-1\/variable_frequency_ac_dc_hipot_test_equipment_fast_discharge_high_accuracy.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"9912 and 9914","Certification":"ISO9001:2008","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"30-300Hz Frequency High Voltage Resonant Test System With Variable Frequency","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/51\/57\/12967b2741ff20cc91c9490c5eb2-200x200-1\/30_300hz_frequency_high_voltage_resonant_test_system_with_variable_frequency_power_source.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX-4800KVA\/200KV,400KV,600KV,800KV","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Long HV XLPE Cable Testing Device \/ Hv Test Equipment 3000KVA Or OEM Capacity","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/e5\/88\/abe10f57a9540377071125232e76-200x200-1\/long_hv_xlpe_cable_testing_device_2f_hv_test_equipment_3000kva_or_oem_capacity.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX-3000KVA\/150KV","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/21\/c7\/fbeed73c2c43a6a643096c871ad4-200x200-1\/variable_inductance_ac_resonant_test_system_hydraulic_type_for_hv_gis_or_cvt.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX(LYY) Series","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"High Accuracy Thermal Generator Test Equipment \/ Ac High Voltage Tester Low","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/0d\/db\/a0fa8cc64da0b19d02a6d19e1477-200x200-1\/high_accuracy_thermal_generator_test_equipment_2f_ac_high_voltage_tester_low_noise.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX-L-350KVA\/50KV","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Durable PD Free AC Resonant Test System No Corona Induced Withstand Voltage Test","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/1e\/3f\/e4b6afae5dbe43b41a46a9ead308-200x200-1\/durable_pd_free_ac_resonant_test_system_no_corona_induced_withstand_voltage_test_sets.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"FKWJF 300","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
PD Free Resonant Withstand Voltage Test Set , Transformer Induced Voltage Withstand And Partial Discharge Test
I. Products description :
FKWJF series test system is mainly used for field induced voltage withstand and partial discharging test of power transformers 110KV class and above. This system adopts PD free push-pull variable-frequency power source technique which ensure fine sine wave and proper test frequency output during testing under iron core unsaturated condition of power transformer .The system can also be designed compatible to test long distance XLPE cable or HV GIS.The above pictures is for transformer induced voltage withstand &partial discharge test system made by Fanke to testing for 220KV power transformer in the field.
Induced voltage withstand test(IVWT), also called induced overvoltage withstand test ,ACSD,ACLD, DVDF, is one of most important dielectric test of power transformers.As per IEC60076-3-2013, IVWT is necessary routine test and acceptance test ater installation for abobe 110KV Power transformer .
II. Applicable objects
Transformer with Graded insulation of 110KV
Transformers of 220KV,500KV,750KV,1000KV Class.
AC voltage withstand test can be made for GIS, transformers,switches,bushing and cables nomore than 1000kv if equipped with proper series resonance HV reactors.
III. System Composition
PD free push-pull variable-frequency power source&observe&controlling cabinet,
PD free excitation transformers,
Loss compensation test reactor,
Partial discharging test instrument
Coupling Voltage divider
Necessary test accessories
IV. Technical Features
Linear power amplifier circuit designed, whole sine wave output, little wave distortion.
Multiple protection includes:discharge breakdown protection, over voltage setting protection,output short-circuit protection,start up null position protection,bridge arm amplification loop protection, power curve protection. Any kind of the above protection works, voltage output will be blocked immediately the major loop power supply will be cut off to guarantee the safety of personnel,tested objects and test system.
The signal source of the device is produced from dedicated chip,the output frequency stability can be as high as 0.0001Hz. and the output voltage is controlled by singlechip which guarantee the degree of instability of voltage less than 1%.
With setting function of test parameters such as test voltage and time, automatic and manual controlling methods.
With voltage automatic stabilization adjustment function, constant output of voltage when frequency regulation within the scope of settled.
Optical controlled,insulated completely HV and low voltage control loops.
Continuously adjustable in a test frequency range of 20—400Hz and with automatic look-up function of resonance frequency. Being able to set multistage of frequency detection.
LCD display and multiple rotary mouses controlled, friendly human-computer interface, simple and convenient for operation and wire drawing.
The variable frequency power source is shielded by high permeability magnetic material with ability of anti-strong disturbance of electric field and ensure the measurement accuracy and stability.
This device can be equipped with special test vehicle and container together
V. General Technical Data:
1 Capacity of variable-frequency power source : 3kW~450kW(Optional According to system model);
2 Rated input voltage: Three phase 380V±10%,50Hz
3 Rated output voltage of test system: Max up to 1200KV(Special spec. can be made by order)
4 Rated output current of test system: Can be made by order
5 Output test frequency: 20-400Hz
6 PD level itself : ≤ 5pCunder rated output voltage
7 Output waveform: Standard sine wave,waveform deviation factor ≤ 1%
8 Degree of instability of output voltage: ≤ 1.0%
9 Degree of instability of output frequency: ≤ 0.05%
Suntech Power Group is one of the largest Procurement, Engineering & Contracting Group companies in China.Our group branch company and factory have already engaged
in the field of electric power more than 26 years.
1.Steel structure industry especially steel towers and related pr... Suntech Power Group is one of the largest Procurement, Engineering & Contracting Group companies in China.Our group branch company and factory have already engaged
in the field of electric power more than 26 years.
1.Steel structure industry especially steel towers and related pr...