Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"High Accuracy Thermal Generator Test Equipment \/ Ac High Voltage Tester Low","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/0d\/db\/a0fa8cc64da0b19d02a6d19e1477-200x200-1\/high_accuracy_thermal_generator_test_equipment_2f_ac_high_voltage_tester_low.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX-L-350KVA\/50KV","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Variable Frequency AC DC Hipot Test Equipment Fast Discharge High Accuracy","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/82\/48\/e56381f41b0590684b4a14d5371e-200x200-1\/variable_frequency_ac_dc_hipot_test_equipment_fast_discharge_high_accuracy.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"9912 and 9914","Certification":"ISO9001:2008","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"30-300Hz Frequency High Voltage Resonant Test System With Variable Frequency","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/51\/57\/12967b2741ff20cc91c9490c5eb2-200x200-1\/30_300hz_frequency_high_voltage_resonant_test_system_with_variable_frequency_power_source.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX-4800KVA\/200KV,400KV,600KV,800KV","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Long HV XLPE Cable Testing Device \/ Hv Test Equipment 3000KVA Or OEM Capacity","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/e5\/88\/abe10f57a9540377071125232e76-200x200-1\/long_hv_xlpe_cable_testing_device_2f_hv_test_equipment_3000kva_or_oem_capacity.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX-3000KVA\/150KV","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/21\/c7\/fbeed73c2c43a6a643096c871ad4-200x200-1\/variable_inductance_ac_resonant_test_system_hydraulic_type_for_hv_gis_or_cvt.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"CHX(LYY) Series","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"PD Free Ac Resonant Test Set Partial Discharge Test Equipment No More Than 10pC","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/84\/c0\/063309222a1eff32cbcb575183f1-200x200-1\/pd_free_ac_resonant_test_set_partial_discharge_test_equipment_no_more_than_10pc.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"FKWJF Series","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
{"title":"Durable PD Free AC Resonant Test System No Corona Induced Withstand Voltage Test","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/1e\/3f\/e4b6afae5dbe43b41a46a9ead308-200x200-1\/durable_pd_free_ac_resonant_test_system_no_corona_induced_withstand_voltage_test_sets.jpg","attrs":{"Brand Name":"Ningbo Suntech Power","Model Number":"FKWJF 300","Certification":"ISO9001","Place of Origin":"Ningbo\uff0cChina"}}
Power Frequency AC Resonant Withstand Voltage Test Set , For Thermal Generators Test
I. Product Description :
According to the relevant test standards from IEC and IEEE, at the time of overhaul or new erection of the generator , the stator winding of the large capacity thermal power generator needs to conduct AC withstand voltage test at 50 or 60Hz power frequency.
AC resonant test set can be classified as variable frequency and variable inductance resonant test system. Power frequency AC resonant withstand voltage test set for large capacity thermal generators is tuned to resonance by regulating inductance. Large capacity output on test object can be obtained by inputting small capacity power supply and samll layout space through using the set. So the test set is usually used for on-site AC withstand voltage test and PD detecting HV source for power generator.The test set model CHX-350KVA/50KV is designed and used for testing 600MW and below class thermal generators .
II. Appication
600MW and below thermal generators
100MW and below hydraulic generators
III. Main Components:
SN
Name of Components
Type and specification
Qty.
Each weight
Each Dimension
1
Resonance Control console
DCG-L-50KVA/380V
1piece
25kgs
600*360*850mm
2
Electric voltage regulator cabinet
DT-50KVA/0~420V
1piece
300kgs
600*500*1150mm
3
Excitation transformer
CQSB-50kVA/8KV
1piece
300kgs
650*650*800mm
4
Variable inductance reactor
CHX(TL)-350kVA/50kV
1piece
1000kgs
950*750*1400mm
5
Voltage divider
TRF-50KV
1set
5kgs
D170*H850mm
6
Special test accessories
Note : Special requirement can be made by order.
VI. General Technical data:
Mode of resonant circuit: Series resonant with variable inductance
System model : CHX-L-350KVA/50KV
Input power supply : 380±10%(single-phase),50Hz/60Hz
Rated output capacity: 350kVA
Rated output Voltage:50KV
Rated output current: 7A
PD level itself: no more than 5pC
Reg. Freq range : 50/60Hz
Output Resonance voltage waveform: pure sine wave
THD of output waveform: ≤1%
Insulation level: Under 1.1 times and keeping 1min, normal
Duty cycle : 30mins on under rated current working condition ;
Quality factor of test set itself: Q≥30 ;
Temperature rise: Less than 65K under rated current working 30mints;
Noise level: No more than 65dB
Reactor Structure: oil-immersed with iron tank type ,adjustable inducatance
V. Technology Advantage
Reactive power full compensated, the power of the equipment and power is only less than 1/10 of measured equipment; with smaller volume and lighter compared with the equipment in same capacity.
With large output capacity and small power capacity, low cost, easy to operate and keep safe.
Typical current filter circuit, the output voltage distortion (THD) is very small
The short circuit current after flashover or breakdown is only less than 1/10 (1/Q) of the measured current, can effectively prevent the damage to fault point after breakdown.
Auto blowout the arc after flashover, it is a long and stable process to recover the serial resonant voltage, safe.
VI. Function
Remote control and indication function for the iron-core gap of reactor:The gap sensor is installed in the reactor, which directly reads the iron-core gap on the console to guide operation. The gap limiting switch and indicator are also installed.
Auto step down function when withstanding time is up:Withstanding timing adopts digimatic timer. When withstanding time is up, the system will auto step down.
Zero position close, zero start step up function:With zero limiting function. If the voltage regulator is not at zero position, then the HV output button cannot be closed, assuring the system step up from zero.
Over current protection:The system is with over current relay, which is of high anti interference, fast action, protection test object against over-current damage.
Over voltage and test object flash-over protection functions:This system takes electronic over voltage and flash-over protection board, protects test object against over voltage and flash-over. It is fast, stable and reliable, overcoming the instability, large discreteness and inconvenient adjustment of sphere-gap protection voltage. The setting of over voltage protection is manual adjustment, digital display, which is direct, convenient and accurate. The flash-over protection samples the accident variance of discharging signal falling delay, compares it with basic signal and determines. It is of high accuracy, avoiding possible mistake movement by accident variance of rising delay.
Real-time monitor function for test data:It is able to monitor HV side voltage, current and LV side voltage, current, which is more direct viewing the test status.
Digital display of circuit resonance and locking function when it is not of resonance and step up:
It can directly display the resonance status of the system by power factor. If the system is not at the resonant point, it must press close button to step up. When the system is adjusted to resonance, release the close button, click on the step up/down button to step up or step down.
Emergency stop :“Step on” emergency brake switch. Once there is abnormal conditions during test, step on this switch, the main power will be cut off right away to protect the safety of the testing personnel and the equipment.
VII.Accessories
Accessory box for storage accessoires
Connection cables of control console and Voltage regulator
Connection cables of voltage ragulator and exciting transformer
Output cables of exciting transformer
System grounding cables
Parallel cables of the reactor
HV output cables(reactor to divide,divider to test object)
HV measuring cables ( the signal output cables of voltage divider )
A final test report, a quality Certificate ,a user manual and a packing list are offered .
VIII. Application Sale list
SN
Project Name
Rated capacity of generator
Typical model supplied of test set
Country
Order Qty.
1
Three Gorges Hydropower Station
700MW Hydroelectric generator
CHX-L-2350KVA/55KV
China
2set
2
Gezhouba Hydropower Station
170MW Hydroelectric generator
CHX-L-1100KVA/40KV
China
2set
3
Xiluodu Hydropower Station
770MW Hydroelectric generator
CHX-L-2850KVA/55KV
China
2set
4
Xiangjiaba Hydropower Station
800MW Hydroelectric generator
CHX-L-3750KVA/65KV
China
2set
5
Wudongde Hydropower Station
850MW Hydroelectric generator
CHX-L-5100KVA/60KV
China
2set
6
Baihetan Hydropower Station
1000MW Hydroelectric generator
CHX-L-4800KVA/65KV
China
2set
7
SON LA Hydropower Station
400MW Hydroelectric generator
CHX-L-1125KVA/45KV
Vietnam
1set
IX. Optional model
Model
Rated voltage
Rated output current
Rated output capacity
Application for turbine generator or thermal power generator
CHX-L-250KVA/50KV
50KV
5A
250KVA
For 300MW and below generator stator
CHX-L-350KVA/50KV
50KV
7A
350KVA
For 600MW and below generator stator
CHX-L-600KVA/50KV
50KV
12A
600KVA
For 1000MW and below generator stator
Special requirement can be made by order
X. Test standard table from IEC60034-1:2017 Rotating electrical machines - Part.1 :Rating and performance
Suntech Power Group is one of the largest Procurement, Engineering & Contracting Group companies in China.Our group branch company and factory have already engaged
in the field of electric power more than 26 years.
1.Steel structure industry especially steel towers and related pr... Suntech Power Group is one of the largest Procurement, Engineering & Contracting Group companies in China.Our group branch company and factory have already engaged
in the field of electric power more than 26 years.
1.Steel structure industry especially steel towers and related pr...