Payment Terms | T/T |
Supply Ability | 500 UNITS/YEAR |
Delivery Time | 30 work days/ unit |
Packaging Details | Naked |
Power frequency withstand voltage at 1 min (effective value) | 230/265 KV |
Creepage distance of insulators | 16mm/kV、20mm/kV、25mm/kV; |
Ice thickness | ≤100 Mm |
Mechanical lifes | CB:2000 Times ; Grounding Switch:2000 Times |
Center distance between phases | ≥2000 Times |
Clamping force of the main blade moving contact plate | ≥140±30 N |
Rated current | 1600/1250/630 A |
Inter phase insulation distance | ≥1000 Times |
Brand Name | TIANAN |
Model Number | GW5(GT10)-126D |
Place of Origin | CHINA |
Certification | IEC 、GB |
View Detail Information
Explore similar products
145kV Outdoor Disconnect Switch Substation Double Side Break Disconnector
252kv High Voltage Disconnect Switch
AC Hv Disconnect Switch
12 - 35KV Indoor High Voltage Disconnect Switch For Protect And Control
Product Specification
Payment Terms | T/T | Supply Ability | 500 UNITS/YEAR |
Delivery Time | 30 work days/ unit | Packaging Details | Naked |
Power frequency withstand voltage at 1 min (effective value) | 230/265 KV | Creepage distance of insulators | 16mm/kV、20mm/kV、25mm/kV; |
Ice thickness | ≤100 Mm | Mechanical lifes | CB:2000 Times ; Grounding Switch:2000 Times |
Center distance between phases | ≥2000 Times | Clamping force of the main blade moving contact plate | ≥140±30 N |
Rated current | 1600/1250/630 A | Inter phase insulation distance | ≥1000 Times |
Brand Name | TIANAN | Model Number | GW5(GT10)-126D |
Place of Origin | CHINA | Certification | IEC 、GB |
High Light | 230/265 KV Disconnect Switch |
The High Voltage Disconnect Switch is made up of several key components, including insulators, contacts, operating mechanism, and a support structure. The insulators are made of high-quality materials and have a creepage distance of 16mm/kV, 20mm/kV, or 25mm/kV, depending on the application. The contacts are made of copper or copper alloy and are designed for high conductivity and low resistance. The operating mechanism is easy to use and provides reliable switching performance. The support structure is made of steel and provides excellent stability and durability.
The High Voltage Disconnect Switch has a mechanical life of 2000 times for both CB and Grounding Switch. It can operate at an altitude of up to 1000 meters and in an ambient temperature range of -25 ~ 40℃. The switch has a rated voltage of 126 KV and is suitable for use in high voltage power systems.
The High Voltage Disconnect Switch is widely used in power transmission and distribution systems, as well as in other applications where high voltage electricity is present. It is an essential tool for ensuring the safety of workers and equipment during maintenance, repair, and emergency situations.
Technical Parameter | Description |
---|---|
Product Name | High-power Disengaging Breaker |
Clamping force of the main blade moving contact plate | ≥140±30 N |
Power frequency withstand voltage at 1 min (effective value) | 230/265 KV |
Center distance between phases | ≥2000 Times |
Rated current | 1600/1250/630 A |
Mechanical lifes | CB:2000 Times ; Grounding Switch:2000 Times |
Isolation switch main circuit resistance | ≤75 μΩ |
Ambient temperature | -25 ~ 40°C |
Inter phase insulation distance | ≥1000 Times |
Ice thickness | ≤100 Mm |
Creepage distance of insulators | 16mm/kV,20mm/kV,25mm/kV |
Product Type | Electricity Cutoff Tool |
The GW5 (GT10) -126D/1600-40 outdoor AC high voltage isolation switch is a double column horizontal rotary structure, with each pole of the switch consisting of a base, a current circuit, and two post insulators. There is a pair of bevel gears inside the base that can move up and down along their respective axes to adjust the meshing condition of the two gears. The two post insulators form a V-shaped angle of
50 °: the current circuit is located at the upper end of the post insulator. When in motion, the umbrella gear inside the base drives the two insulators to rotate, thereby driving the conductive arm connected to it to rotate 90 degrees, forming a horizontal fracture and completing the opening and closing of the circuit.
GW5 (GT10) -126D/1600-40 horizontal single break outdoor AC high-voltage isolation switch is suitable for systems with an AC frequency of 50Hz and a rated voltage of 110KV. Used for switching high-voltage lines under no-load conditions, as well as electrically isolating high-voltage busbars, circuit breakers, and other electrical equipment under maintenance from live high-voltage lines. It can also be used for switching small capacitive or inductive currents.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
1969
Total Annual:
250000000-300000000
Employee Number:
3000~3500
Ecer Certification:
Verified Supplier
Ningbo Tianan (Group) Co, Ltd is a famous leading influential enterprise of the power transmission equipment manufacturing in China.It was founded in 1969,currently under the group, we have 1 national-level R&D center, 2 provincial-level R&D center, 10 professional companies, 70 sales office... Ningbo Tianan (Group) Co, Ltd is a famous leading influential enterprise of the power transmission equipment manufacturing in China.It was founded in 1969,currently under the group, we have 1 national-level R&D center, 2 provincial-level R&D center, 10 professional companies, 70 sales office...
Get in touch with us
Leave a Message, we will call you back quickly!