Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Dixell Digital Refrigeration Controller","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/0b\/5c\/7adf43653b007251923c1dbf1b1b-200x200-1\/dixell_digital_refrigeration_controller.jpg","attrs":{"Brand Name":"Dixell","Model Number":"XR06CX-5N0C1","Certification":"EAC","Place of Origin":"Italy \/ China"}}
{"title":"Dixell Digital Controller XR02CX 5N0C1 With PTC Sensor","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/b8\/52\/e6056bea028c8843e28761ed47c1-200x200-1\/dixell_digital_controller_xr02cx_5n0c1_with_ptc_sensor.jpg","attrs":{"Brand Name":"Dixell","Model Number":"XR02CX-5N0C1","Certification":"EAC","Place of Origin":"Italy \/ China"}}
{"title":"XR60CX Dixell Temperature Controller For Coldroom Freezer Room","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/af\/3c\/bb85cda7426b5bde21c9dbfc6ce5-200x200-1\/xr60cx_dixell_temperature_controller_for_coldroom_freezer_room.jpg","attrs":{"Brand Name":"Dixell","Model Number":"XR60CX","Certification":"EAC","Place of Origin":"Italy \/ China"}}
{"title":"ID Plus 971 974 Eliwell Digital Refrigeration Controller 230VAC","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/aa\/f2\/e11ab5c42206bc66f84795c5a0d9-200x200-1\/id_plus_971_974_eliwell_digital_refrigeration_controller_230vac.jpg","attrs":{"Brand Name":"Dixell","Model Number":"ID Plus 902 \/ 961 \/ 971 \/ 974","Certification":"EAC","Place of Origin":"Italy \/ China"}}
{"title":"SF 104S Digital Refrigeration Controller Electric Heater Automatic Defrost","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/7d\/08\/97d1b8037a3ac10ac53cbfe97333-200x200-1\/sf_104s_digital_refrigeration_controller_electric_heater_automatic_defrost.jpg","attrs":{"Brand Name":"SF","Model Number":"SF-104S","Certification":"CE","Place of Origin":"China"}}
{"title":"SF-101S 220V Digital Refrigeration Controller 77mm Length","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/55\/c0\/024ad879c9d6bb010848ab418bdc-200x200-1\/sf_101s_220v_digital_refrigeration_controller_77mm_length.jpg","attrs":{"Brand Name":"SF","Model Number":"SF-101S","Certification":"CE","Place of Origin":"China"}}
{"title":"SF 102S AC12V Chiller Freezer Digital Temperature Controller For 1 HP Compressor","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/10\/1a\/c33f967c2f9c68c77b2d1d01ba48-200x200-1\/sf_102s_ac12v_chiller_freezer_digital_temperature_controller_for_1_hp_compressor.jpg","attrs":{"Brand Name":"SF","Model Number":"SF-102S","Certification":"CE \/ UL \/ SGS \/ CQC","Place of Origin":"China"}}
Orginal Dixell Digital Refrigeration Controllers XR06CX-5N0C1 With Defrost And Fan Management For Coldroom And Freezer
GENERAL DESCRIPTION
The XR06CX, format 32 x 74 x 60 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost which can be either electrical or reverse cycle (hot gas). The device is also provided with 2 NTC probe inputs, the first one for temperature control and the second one to be located onto the evaporator, to control the defrost termination temperature and to managed the fan and it’s provided with a configurable digital input. With the HOTKEY it’s possible to program the instrument in a quick and easy way.
SPECIFICATIONS / MODELS
XR01CX
XR02CX
XR03CX
XR04CX
XR06CX
Dimension
32*74*50mm
√
√
√
√
32*74*60mm
√
Power supply
12,24V ac/dc (± 10%)
√
√
√
√
√
115,230V ac/dc (± 10%)
√
√
√
√
√
Temperature sensor
Coldroom Temp Probe NTC / PTC
√ / optional
√ / optional
√ / optional
√ / optional
√ / optional
Defrost / Fan Probe NTC / PTC
√ / optional
√ / optional
√ / optional
√ / optional
√ / optional
Function digital signal input
√
√
√
√
Outout
Load or compressor
20A / 8A
20A / 8A
20A / 8A
20A / 8A
20A / 8A
Defrost
Shut down defrost
Shut down defrost
8A
8A
Fan
8A
Light / Auxiliary output
8A
Others
Hot Key Programming key
√
√
√
√
√
Heating / Cooling
Heating / Cooling
Heating / Cooling
Heating / Cooling
Cooling
Cooling
XR10CX
XR20CX
XR30CX
XR40CX
XR50CX
XR60CX
XR70CX
Dimension
32*74*60mm
√
√
√
√
√
√
√
Power supply
12,24V ac/dc (± 10%)
√
√
√
√
√
√
115,230V ac/dc (± 10%)
√
√
√
√
√
√
√
Display
3 digital tubes, minus sign,Decimal point,Output status minus sign
√
√
√
√
√
√
√
Temperature sensor
Coldroom Temp Probe NTC / PTC
√
√
√
√
√
√
√
Evaporator Probe NTC / PTC
√
√
√
√
√
√
√
second Evaporator Probe NTC / PTC
√
√
√
√
Condenser Probe NTC / PTC
√
√
√
√
√
√
√
Digital input/display probe
Alarm,Trigger Defrost,Auxiliary probe, door switch,Pressure switch
Settable
Settable
Settable
Settable
Settable
Settable
Settable
Relay Outout
compressor
20A / 8A
20A / 8A
20A / 8A
20A / 8A
20A / 8A
20A / 8A/16A
20A / 8A/16A
Defrost
8A
8A
8A
8A/16A
Evaporator Fan
5A/8A
5A/16A
Light / Alarm output
8A
5A/8A
8A/16A
Others
Hot Key Programming key
√
√
√
√
√
√
√
Serial Interface MODBUS
√
√
√
√
√
√
√
DEFROST
Two defrost modes are available through the “td” parameter:
• td=EL → defrost through electrical heater (compressor OFF)
• td=in → hot gas defrost (compressor ON).
Other parameters are used to control the interval between defrost cycles (id) ), its maximum length (Md) and two defrost modes: timed or controlled by the evaporator’s probe. At the end of defrost dripping time is started, its length is set in the dt parameter. With dt=0 the dripping time is disabled
FANS
With FC parameter it can be selected the fans functioning:
• FC=cn → will switch ON and OFF with the compressor and not run during defrost
• FC=on → fans will run even if the compressor is off, and not run during defrost
After defrost, there is a timed fan delay allowing for drip time, set by means of the “Fd” parameter.
• FC=cy → fans will switch ON and OFF with the compressor and run during defrost
• FC=oY → fans will run continuously also during defrost.
An additional parameter “FS” provides the setting of temperature, detected by the evaporator probe, above which the fans are always OFF. This is used to make sure circulation of air only if his temperature is lower than set in “FS”
FANS AND DIGITAL INPUT
When the digital input is configured as door switch iF=do, fans and compressor status depends on the dC parameter value:
• dC=no → normal regulation;
• dC=Fn → fans OFF;
• dC=cP → compressor OFF;
• dC=Fc → compressor and fans OFF.
When rd=y, the regulation restart with door open alarm.
FRONT PANEL COMMANDS
HOW TO SEE THE SET POINT
1.Push and immediately release the SET key, the set point will be showed;
2.Push and immediately release the SET key or wait about 5s to return to normal visualisation.
HOW TO CHANGE THE SETPOINT
1.Push the SET key for more than 2 seconds to change the Set point value;
2.The value of the set point will be displayed and the “°C” or “°F” LED starts blinking;
3.To change the Set value push the or arrows.
4.To memorise the new set point value push the SET key again or wait 10s.
HOW TO START A MANUAL DEFROST
Push the DEF key for more than 2 seconds and a manual defrost will start
HOW TO CHANGE A PARAMETER VALUE
To change the parameter’s value operate as follows:
1. Enter the Programming mode by pressing the SET+keys for 3s (“°C” or “°F” LED starts blinking).
2. Select the required parameter. Press the “SET” key to display its value
3. Use ↑ or ↓ to change its value.
4. Press “SET” to store the new value and move to the following parameter.
To exit: Press SET+↑ or wait 15s without pressing a key.
NOTE: the set value is stored even when the procedure is exited by waiting the time-out to expire.
ALARM SIGNALLING
Mess. Cause Outputs
"P1" Room probe failure Compressor output according to “Cy” e “Cn”
"P2" Evaporator probe failure Defrost end is timed
We founded in 2003, specialized in all kinds of refrigeration line products. Like condensing units, compressors, freezing and air conditioning components. We have abundant technology with excellent service working team.
Now we are representing and selling more than 10 brands refrigerati... We founded in 2003, specialized in all kinds of refrigeration line products. Like condensing units, compressors, freezing and air conditioning components. We have abundant technology with excellent service working team.
Now we are representing and selling more than 10 brands refrigerati...