Payment Terms | T/T |
Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks |
Packaging Details | Reinforced Carton box with wooden tray |
Key word | Cold climate Air Source Heat Pump |
Use | household, hotel, apartment etc. |
Tankless/tank | Tankless |
Installation | wall or floor mouted |
ambient temeprature | -25C~+45C |
Electricity | 220V-3N-50hz |
Brand Name | Yushen |
Model Number | 9Kw, 14Kw, 18KW |
Certification | CCC, ISO, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
Lab Building Central Air Source Heat Pump High COP Under -13F Winter
Freon R404a Home Air Source Heat Pump One Compressor Electricity AC Outdoor Unit
Automatic Cold Climate Air Source Heat Pump , Split System Heat Pump
7kw Cold Climate Air Source Heat Pump , Mini Split Heat Pump Fan Outdoor Unit
Product Specification
Payment Terms | T/T | Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks | Packaging Details | Reinforced Carton box with wooden tray |
Key word | Cold climate Air Source Heat Pump | Use | household, hotel, apartment etc. |
Tankless/tank | Tankless | Installation | wall or floor mouted |
ambient temeprature | -25C~+45C | Electricity | 220V-3N-50hz |
Brand Name | Yushen | Model Number | 9Kw, 14Kw, 18KW |
Certification | CCC, ISO, CQC | Place of Origin | China |
High Light | cold climate heat pump systems ,all climate heat pump |
Air Energy Heat Pump Air Conditioning And Hot Water Unit Suitable for Cold Climate
ASHP characters
1.Work under the temperature -25°C stably with good COP, by adopting the super inverter tech Copeland compressor special designed.
2.Base frame and external panels made of galvanized powder coated steel
3.Water exchanger equipped with high efficiency tube in heat exchanger
4.High efficiency compressor with R410a refrigerant
5.Fully sealed control box with water proof level IPX4
6.Automatic defrosting function included
Parameters
Model | SLNA(B)-009U(P) | SLNA(B)-014U(P) | SLNA-018U | |||
Compressor capacity | 3HP | 5HP | 6HP | |||
Function | Heating and Cooling | Heating and Cooling | Heating and Cooling | |||
Electricity | 220V-1N-50Hz | 220V-1N-50Hz | 220V-1N-50Hz | |||
Working conditions | ℃ | -25~~+45 | -25~~+45 | -25~~+45 | ||
Data | Heata | Nominal capacity | KW | 5.8 | 9.2 | 12 |
Input power | KW | 2.52 | 3.96 | 5.0 | ||
COP | / | 2.3 | 2.3 | 2.4 | ||
Heating IPLV(H) | 2.53 | 2.6 | 2.7 | |||
Coolb | Nominal capacity | KW | 6.5 | 11.0 | 14 | |
Input power | KW | 2.6 | 4.31 | 5.6 | ||
COP | / | 2.5 | 2.55 | 2.5 | ||
Cooling IPLV(C) | 2.7 | 2.75 | 2.7 | |||
A7W35c | KW/COP | 9.2/4.10 | 14.0/4.1 | 19.5/4.21 | ||
A2W35 | KW/COP | 8.0/3.6 | 11.2/3.60 | 16.8/3.65 | ||
A-7W35 | KW/COP | 5.9/2.7 | 9.5/3.0 | 12.0/3.0 | ||
A-15W55 | KW/COP | 5.0/1.90 | 8.4 /1.94 | 10.8 /1.94 | ||
A-20W45 | KW/COP | 4.5/1.95 | 7.7/2.00 | 9.2/2.02 | ||
Max. running currency | A | 18 | 30 | 35.6 | ||
Compressor quantity | set | 1 | 1 | 1 | ||
Refrigerant/charging quantity kg | / | R404A/2.2 | R22/4.50 | R22/4.80 | ||
Air blow type | / | Side | Side | Side | ||
Water pipe diameter | inch | G1〞 | G1.2〞 | G1.2〞 | ||
Rating flow | m³/h | 1.6 | 2.5 | 3.2 | ||
Water side pressure loss | kPa | ≤35 | ≤35 | ≤45 | ||
Noise level | dB(A) | 59 | 61 | 61 | ||
Overall dimensions(L×W×H) | mm | 1087×435×901 | 1120×440×1360 | 1120×440×1360 | ||
Weight | kg | 70 | 130 | 249 |
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
Yushen Products
Multiple energy-saving devices in a single system, precise control of refrigerant flow, enabling the unit to maximize heat/cooling capacity and maximum energy efficiency in various working environments, reducing operating costs
The industry's leading refrigerant distribution technology can effectively improve the uniformity of gas-liquid two-phase fluid distribution into heat transfer tubes, improve the utilization of heat exchange tubes, and achieve efficient heat transfer.
The four-row tube V-shaped arrangement has high heat exchange efficiency and uniform wind speed distribution.
It adopts 9.52*0.35 internal thread high-efficiency heat exchange copper tube and 3.1mm large-format hydrophilic aluminum fins with better hydrophobicity; it improves the operating efficiency during frosting and reduces the number of defrosting.
The optimized long flow path design and wide expansion of the expansion throttle ensure uniform distribution of refrigerant in low temperature environments. Ensure even frosting, complete defrosting, strong heating and efficient operation
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
7000000-12000000
Ecer Certification:
Active Member
Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...
Get in touch with us
Leave a Message, we will call you back quickly!