Payment Terms | T/T |
Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks |
Packaging Details | Reinforced Carton box with wooden tray |
Key word | Cold Climate Heat Pump Systems |
Application | Home Use |
Rated temperature in summer | 7C |
Refrigerant | r410a r407c |
Suitable working conditions | -25C~+45C |
Feature | Powerful |
Brand Name | Yushen |
Model Number | SLNA-007UM , SLNA(B)-009UP, SLNA-028U |
Certification | CCC, ISO, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
Household High Temperature Air Source Heat Pumps Side Air Blow 70 Kg
Space Saving Residential Air Source Heat Pump , Split System Heat Pump
Village Houses Air Source Heat Pump Underfloor Heating CCC Standard
Villa Heat Pump Heating And Cooling System , Underfloor Heating Pump
Product Specification
Payment Terms | T/T | Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks | Packaging Details | Reinforced Carton box with wooden tray |
Key word | Cold Climate Heat Pump Systems | Application | Home Use |
Rated temperature in summer | 7C | Refrigerant | r410a r407c |
Suitable working conditions | -25C~+45C | Feature | Powerful |
Brand Name | Yushen | Model Number | SLNA-007UM , SLNA(B)-009UP, SLNA-028U |
Certification | CCC, ISO, CQC | Place of Origin | China |
High Light | cold climate heat pump systems ,heat pump in cold weather |
Home Use Cold Climate Heat Pump Systems / Powerful Air Exchange Heat Pump
Cold Climate Heat Pump Systems Features
● Efficient and Energy-saving
Air source heat pumps absorb hot energy from the air freely, and the electricity is only used to drive the compressor to pump up the heat from the air. So, it consumes just a quarter of traditional electric heaters, saving a lot of electric costs for users.
● Green and Environmental Protection
By using air hot energy and electric energy, there is no harmful gas being discharged during the operation of heat pumps. R407C refrigerant guarantees fluoride-free emission.
● Usable All-weather
All weather operation: stable operation without being influenced by any windy, rainy or snowy weather.
● Endurable
The Enhanced Vapor Injection (EVI) technology from Copeland compressor with crankcase heater for special cold area, Danfoss electronic expansion valve, Eaton AC contactor and thermal relay and other brand components of the heat pump guarantee high quality and a long lifespan. All of our screws and clips (both external and internal) are stainless steel. The cabinets we are using are made of GALVANIZED STEEL, making them more rust resistant, durable and affordable.
Cold Climate Heat Pump Systems Parameters
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
Model | SLNA-007UM | SLNA(B)-009U(P) | SLNA-028U | |||
Compressor capacity | 2HP | 3HP | 9HP | |||
Function | Heating and Cooling | Heating and Cooling | Heating and Cooling | |||
Electricity | 220V-1N-50Hz | 220V-1N-50Hz | 220V-1N-50Hz | |||
Working conditions | ℃ | -25~~+45 | -25~~+45 | -25~~+45 | ||
Data | Heata | Nominal capacity | KW | 3.9 | 5.8 | 18.4 |
Input power | KW | 1.69 | 2.52 | 7.8 | ||
COP | / | 2.3 | 2.3 | 2.3 | ||
Heating IPLV(H) | 2.53 | 2.53 | 2.7 | |||
Coolb | Nominal capacity | KW | 4.4 | 6.5 | 22 | |
Input power | KW | 1.69 | 2.6 | 8.6 | ||
COP | / | 2.6 | 2.5 | 2.5 | ||
Cooling IPLV(C) | 2.7 | 2.7 | 2.7 | |||
A7W35c | KW/COP | 6.4/4.1 | 9.2/4.10 | 28.0/4.1 | ||
A2W35 | KW/COP | 5.8/3.6 | 8.0/3.6 | 22.4/3.60 | ||
A-7W35 | KW/COP | 4.3/2.7 | 5.9/2.7 | 19/3.0 | ||
A-15W55 | KW/COP | 3.4/1.9 | 5.0/1.90 | 16.8 /1.94 | ||
A-20W45 | KW/COP | 2.9/1.94 | 4.5/1.95 | 15.4/2.02 | ||
Max. running currency | A | 13.2 | 18 | 60 | ||
Compressor quantity | set | 1 | 1 | 2 | ||
Refrigerant/charging quantity kg | / | R404A/2.2 | R404A/2.2 | R22/3.7*2 | ||
Air blow type | / | Side | Side | Top | ||
Water pipe diameter | inch | G1〞 | G1〞 | G1.5〞 | ||
Rating flow | m³/h | 1.6 | 1.6 | 5 | ||
Water side pressure loss | kPa | ≤35 | ≤35 | ≤45 | ||
Noise level | dB(A) | 59 | 59 | 62 | ||
Overall dimensions(L×W×H) | mm | 1087×435×901 | 1087×435×901 | 1530×750×1370 | ||
Weight | kg | 70 | 70 | 30 |
Yushen Cold Climate Heat Pump Systems Advantages
1. Yushen ASHP could work in untra low temeprature cold climate -25C
2. More than 6 million M2 heating area project cases all over the different latitude area.
3. long heating time and less defrosting time,35% more powerful than other products
4.Automatic testing line,100% finished products testing
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
7000000-12000000
Ecer Certification:
Active Member
Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...
Get in touch with us
Leave a Message, we will call you back quickly!