China High Efficiency Cold Climate Air Source Heat Pump Home Heating And Cooling
China High Efficiency Cold Climate Air Source Heat Pump Home Heating And Cooling

  1. China High Efficiency Cold Climate Air Source Heat Pump Home Heating And Cooling

High Efficiency Cold Climate Air Source Heat Pump Home Heating And Cooling

  1. MOQ: 1 set
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10 sets/day
Delivery Time 1-2weeks
Packaging Details Reinforced Carton box with wooden tray
Name Cold Climate Air Source Heat Pump
Feature High Efficiency
Rated temperature in summer 7C
Refrigerant r410a r407c
Suitable working conditions -25C~+45C
Application Geothermal Home Heating And Cooling
Brand Name Yushen
Model Number SLNA-007UM , SLNA(B)-009UP, SLNA-028U
Certification CCC, ISO, CQC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10 sets/day
Delivery Time 1-2weeks Packaging Details Reinforced Carton box with wooden tray
Name Cold Climate Air Source Heat Pump Feature High Efficiency
Rated temperature in summer 7C Refrigerant r410a r407c
Suitable working conditions -25C~+45C Application Geothermal Home Heating And Cooling
Brand Name Yushen Model Number SLNA-007UM , SLNA(B)-009UP, SLNA-028U
Certification CCC, ISO, CQC Place of Origin China
High Light cold climate heat pump systemsheat pump in cold weather

High Efficiency Cold Climate Air Source Heat Pump Home Heating And Cooling

 

Cold Climate Air Source Heat Pump Features

 

Energy Efficient
Cold Climate Air Source Heat Pump absorb hot energy from the air freely, and the electricity is only used to drive the compressor to pump up the heat from the air. So, it consumes just a quarter of traditional electric heaters, saving a lot of electric costs for users.

Environmental Protection
By using air hot energy and electric energy, there is no harmful gas being discharged during the operation of heat pumps. R407a refrigerant guarantees fluoride-free emission.


 All weather Operation
All weather operation: stable operation without being influenced by any windy, rainy or snowy weather.

Endurable


The Enhanced Vapor Injection (EVI) technology from Copeland compressor with crankcase heater for special cold area, Danfoss electronic expansion valve, Eaton AC contactor and thermal relay and other brand components of the heat pump guarantee high quality and a long lifespan. All of our screws and clips (both external and internal) are stainless steel. The cabinets we are using are made of GALVANIZED STEEL, making them more rust resistant, durable and affordable.

Multiple Controller and Protection
High pressure, low pressure, overheating, overload anti-freezing, phase sequence, discharge temperature, suction temperature and so on. Controlled by multiple controller or by computer (optional)

Linkage Function
External signal on/off function

Guaranteed Safety
Complete isolation of water and electricity avoids electric shock, explosion and poisoning; LCD screen digital controller for automatic operation

Convenient
The heat pump is easy to install in many places, such as garage, balcony, kitchen, etc.

 

 

Cold Climate Air Source Heat Pump Parameters

code name.pdf

a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity

b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity

c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃

 

Model SLNA-007UM SLNA-028U
Compressor capacity 2HP 9HP
Function Heating and Cooling Heating and Cooling
Electricity 220V-1N-50Hz 220V-1N-50Hz
Working conditions -25~~+45 -25~~+45
Data Heata Nominal capacity KW 3.9 18.4
Input power KW 1.69 7.8
COP / 2.3 2.3
Heating IPLV(H) 2.53 2.7
Coolb Nominal capacity KW 4.4 22
Input power KW 1.69 8.6
COP / 2.6 2.5
Cooling IPLV(C) 2.7 2.7
A7W35c KW/COP 6.4/4.1 28.0/4.1
A2W35 KW/COP 5.8/3.6 22.4/3.60
A-7W35 KW/COP 4.3/2.7 19/3.0
A-15W55 KW/COP 3.4/1.9 16.8 /1.94
A-20W45 KW/COP 2.9/1.94 15.4/2.02
Max. running currency A 13.2 60
Compressor quantity set 1 2
Refrigerant/charging quantity kg / R404A/2.2 R22/3.7*2
Air blow type / Side Top
Water pipe diameter inch G1〞 G1.5〞
Rating flow m³/h 1.6 5
Water side pressure loss kPa ≤35 ≤45
Noise level dB(A) 59 62
Overall dimensions(L×W×H) mm 1087×435×901 1530×750×1370
Weight kg 70 300

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2014

  • Total Annual:

    7000000-12000000

  • Ecer Certification:

    Active Member

Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...

+ Read More

Get in touch with us

  • Reach Us
  • Shandong Yushen Energy Technology Co., Ltd.
  • Foreign sales office: 588 South Qilianshan Road ,Putuo area, Shanghai,China
  • http://commercialairsourceheatpump.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement