Payment Terms | T/T |
Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks |
Packaging Details | Reinforced Carton box with wooden tray |
key word | Central Air Conditioner Heat Pump |
Compressor capacity | 6Hp ~25HP |
Function | cooling and heating |
Noise level | 62dba |
Compressor brand | High Efficient |
Electricity | 380V-3P-50hz |
Working conditions | -25C ~+45C |
Brand Name | Yushen |
Model Number | 017Y~075Y |
Certification | CCC, ISO, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
62 DBA Air Source Central Air Conditioner Heat Pump , Heating And Cooling Units
Intelligent Control Heat Pump Air Conditioning Unit For Central AC Freon R22
62 Dba Air Cooled Heat Pump Scroll Compressors 40 % Energy Saving
6P - 25P Air Energy Heat Pump , School Central Air Conditioning System
Product Specification
Payment Terms | T/T | Supply Ability | 10 sets/day |
Delivery Time | 1-2weeks | Packaging Details | Reinforced Carton box with wooden tray |
key word | Central Air Conditioner Heat Pump | Compressor capacity | 6Hp ~25HP |
Function | cooling and heating | Noise level | 62dba |
Compressor brand | High Efficient | Electricity | 380V-3P-50hz |
Working conditions | -25C ~+45C | Brand Name | Yushen |
Model Number | 017Y~075Y | Certification | CCC, ISO, CQC |
Place of Origin | China | ||
High Light | central heating and air conditioning units ,heat pump air conditioning unit |
High Efficient Central Air Conditioner Heat Pump Intelligent Management
Central Air Conditioner Heat Pump Features
(1) The air source heat pump system is a combination of cold and heat sources. There is no need to set up a special freezer room or boiler room. The unit can be placed on the roof or the ground at will, without occupying the effective use area of he building. The construction and installation is very simple.
(2) The air source heat pump system has no cooling water system, no cooling water consumption, and no power consumption of the cooling water system. In addition, there have been many reports of Legionella infections caused by cooling water pollution. From the perspective of safety and hygiene, considering air source heat pumps also has obvious advantages.
(3) Air source heat pump system Because the boiler is not needed, the corresponding boiler fuel supply system, dust removal system and flue gas emission system are not needed, the system is safe and reliable, and has no pollution to the environment.
(4) Air source heat pump The cold (hot) water unit adopts modular design. It does not need to set up a standby unit. During the operation, the computer automatically controls and adjusts the running status of the unit to make the output power adapt to the working environment.
(5) The performance of air source heat pumps will vary with outdoor climate changes.
(6) In places where the outdoor air temperature in the north of China is low, an auxiliary heater is required due to insufficient heat supply in the winter of the heat pump.
Model data/ Parameter of Central Air Conditioner Heat Pump
A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal
Model | SLNA-032Y | SLNB-035Y | SLNB-047Y | SLNC-075Y | |||
Compressor capacity | 10HP | 12.5HP | 15HP | 25HP | |||
Function | Heating and Cooling | Heating and Cooling | Heating and Cooling | Heating and Cooling | |||
Electricity | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | 380V-3N-50Hz | |||
Working conditions | ℃ | -25~+45 | -25~+45 | -25~+45 | -25~+45 | ||
Data | Heata | Nominal capacity | KW | 21.5 | 22.3 | 28.1 | 44.5 |
Input power | KW | 9.1 | 9.4 | 11.7 | 18.3 | ||
COP | / | 2.3 | 2.35 | 2.4 | 2.4 | ||
Heating IPLV(H) | 2.7 | 2.7 | 2.7 | 2.7 | |||
Coolb | Nominal capacity | KW | 25 | 28 | 39 | 62 | |
Input power | KW | 10 | 10.4 | 13.1 | 20.7 | ||
COP | / | 2.5 | 2.7 | 2.9 | 3 | ||
Cooling IPLV(C) | 2.7 | 2.7 | 2.7 | 2.7 | |||
A7W35c | KW/COP | 32.0/4.1 | 35.0/4.1 | 47.0/4.1 | 75.0/4.2 | ||
A2W35 | KW/COP | 27/3.60 | 28.5/3.60 | 39.5/3.20 | 62.5/3.20 | ||
A-7W35 | KW/COP | 21.5/2.8 | 23.5/2.9 | 32/2.9 | 50/2.9 | ||
A-15W55 | KW/COP | 19.7 /1.94 | 20.2 /1.94 | 28.1/1.94 | 45.5 /1.97 | ||
A-20W45 | KW/COP | 18.1/2.02 | 18.7/2.02 | 23.6/2.03 | 37.4/2.04 | ||
Max. running currency | A | 25 | 27 | 35 | 56 | ||
Compressor quantity | set | 2 | 1 | 2 | 2 | ||
Refrigerant/charging quantity kg | / | R22/3.7*2 | R22/9 | R22/10 | R22/15*2 | ||
Air blow type | / | Top | Side | Top | Top | ||
Water pipe diameter | mm | 32 | 32 | 50 | 50 | ||
Rating flow | m³/h | 5.5 | 5.9 | 8.3 | 12.6 | ||
Water side pressure loss | kPa | ≤45 | ≤45 | ≤45 | ≤45 | ||
Noise level | dB(A) | 62 | 62 | 62 | 62 | ||
Overall dimensions(L×W×H) | mm | 1530×750×1370 | 1490×900×1900 | 1450×1100×2080 | 2100×1100×2080 | ||
Weight | kg | 320 | 350 | 470 | 730 |
Our service
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
7000000-12000000
Ecer Certification:
Active Member
Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ... Shandong Yushen Energy Technology Co., Ltd. established in 2014 with a registered capital of 50.2 million RMB (about 7 million USD), is a factory specialized in research & development, design, production, sales and service of air-source heat pumps drive by its mission” Leave a clean world ...